1.Development and clinical application of an quantitative head-band formed ocular compressor.
Qing, XIAO ; Shiyi, XIAO ; Yanhua, HU ; Zhi, WANG
Journal of Huazhong University of Science and Technology (Medical Sciences) 2002;22(1):66-8
In order to investigate the efficiency of a new quantitative head-band formed ocular compressor to reduce intraocular pressure (IOP), ocular compression by this new reducer with 40 mmHg for 10 min was performed on 87 cataractous eyes of 78 cases. The changes of IOP (87 eyes) and anterior chamber depth (ACD) were observed. There was a significant decrease of IOP and increase of ACD within 30 min after decompression (P < 0.001). The mean decrease of IOP was 5.62 +/- 2.41 mmHg and the mean increase of ACD was 0.18 +/- 0.09 mm within 5 min after decompression. The IOP 5 min after decompression had no significant difference with that 10 min after decompression (P > 0.05). IOP below 10 mmHg could last for about 15 min. This apparatus had been successfully applied to 80 eyes for extracapsular cataract extraction. It was suggested that this device had the advantages of safety, accurate quantification, reliable effect, casually adjusting pressure according to various demands and time-saving.
Cataract/*physiopathology
;
*Cataract Extraction
;
Compressive Strength
;
Equipment Design
;
*Intraocular Pressure
;
Manometry/instrumentation
;
Preoperative Care
2.Clinical and CT Histological Diagnosis of Orbital Tumors
Yanhua HU ; Jie WANG ; Shiyi XIAO
Journal of Huazhong University of Science and Technology (Medical Sciences) 2000;20(1):82-85
The clinical manifestation and characteristics of CT image of 117 cases of orbital tumors in our hospital were investigated. The hemangioma had the highest incidence, and the less common tumors were, in sequence of incidence, pseudotumor, dermoid cysts, neurilemmoma, polymorphous adenoma and meningioma. The sensitivity in diagnosis of orbital tumor by CT was 93.3%. The coincidence of CT histological diagnosis with pathology were 83.3 %, 82.6 % and 71.4% for dermoid.cysts, hemangioma, and pseudotumor respectively, but the general coincidence of CT histological diagnosis with pathology was only 67.8 %. When CT was combined with ultrasound, cytological examination and clinical manifestations, the accuracy of histological diagnosis could be improved to 83.3 %.
3.Clinical and CT Histological Diagnosis of Orbital Tumors
Yanhua HU ; Jie WANG ; Shiyi XIAO
Journal of Huazhong University of Science and Technology (Medical Sciences) 2000;20(1):82-85
The clinical manifestation and characteristics of CT image of 117 cases of orbital tumors in our hospital were investigated. The hemangioma had the highest incidence, and the less common tumors were, in sequence of incidence, pseudotumor, dermoid cysts, neurilemmoma, polymorphous adenoma and meningioma. The sensitivity in diagnosis of orbital tumor by CT was 93.3%. The coincidence of CT histological diagnosis with pathology were 83.3 %, 82.6 % and 71.4% for dermoid.cysts, hemangioma, and pseudotumor respectively, but the general coincidence of CT histological diagnosis with pathology was only 67.8 %. When CT was combined with ultrasound, cytological examination and clinical manifestations, the accuracy of histological diagnosis could be improved to 83.3 %.
4.Fresh amniotic membrane transplantation for recurrent pterygium
Ping LI ; Qiong XIAO ; Jutian HUANG ; Jun GE ; Xiaoling LUO ; Zhiyuan LIU ; Xian LI ; Wei PENG ; Gefei ZHU ; Shiyi XIAO
Chinese Journal of Primary Medicine and Pharmacy 2006;0(07):-
Objective To explore the efficacy of excision of pterygium combined with fresh amniotic membrane transplantation for treatment of recurrent pterygium.Methods Pteryga of 27 patients(32 eyes) were excised and transplanted with fresh amniotic membrane.Patients were followed up for 6~36 months.Results Pterygium recurred in only 2 eyes during the period of follow-up.The curative rate of the operation for recurrent pterygium was 93.75%,and the recurrence rate was 6.25%.Conclusion Excision of pterygium combined with fresh amniotic membrane transplantation is an effective therapeutic method for recurrent pterygium.
5.Development and clinical application of an quantitative head-band formed ocular compressor.
Qing XIAO ; Shiyi XIAO ; Yanhua HU ; Zhi WANG
Journal of Huazhong University of Science and Technology (Medical Sciences) 2002;22(1):66-68
In order to investigate the efficiency of a new quantitative head-band formed ocular compressor to reduce intraocular pressure (IOP), ocular compression by this new reducer with 40 mmHg for 10 min was performed on 87 cataractous eyes of 78 cases. The changes of IOP (87 eyes) and anterior chamber depth (ACD) were observed. There was a significant decrease of IOP and increase of ACD within 30 min after decompression (P < 0.001). The mean decrease of IOP was 5.62 +/- 2.41 mmHg and the mean increase of ACD was 0.18 +/- 0.09 mm within 5 min after decompression. The IOP 5 min after decompression had no significant difference with that 10 min after decompression (P > 0.05). IOP below 10 mmHg could last for about 15 min. This apparatus had been successfully applied to 80 eyes for extracapsular cataract extraction. It was suggested that this device had the advantages of safety, accurate quantification, reliable effect, casually adjusting pressure according to various demands and time-saving.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Cataract
;
physiopathology
;
Cataract Extraction
;
Child
;
Compressive Strength
;
Equipment Design
;
Female
;
Humans
;
Intraocular Pressure
;
Male
;
Manometry
;
instrumentation
;
Middle Aged
;
Preoperative Care