1.The development of virtual ECG sampling system
Shitao QI ; Liming TANG ; Min WU ; Tiebing LIU ; Haifeng CHEN
Chinese Medical Equipment Journal 1989;0(03):-
This paper introduces a virtual ECG sampling system based on LabVIEW. The system, utilizing self-developed ECG sampling card, fulfils ECG measurement and A/D conversion safely and realizes ECG data processing and display under Labview developing environment.
2.Design of 50Hz notch filter based on MATLAB
Shitao QI ; Liming TANG ; Min WU ; Tiebing LIU
Chinese Medical Equipment Journal 2004;0(08):-
50Hz power frequency interference is the main noise of ECG signal.With the signal processing toolbox of MATLAB,this paper develops a high-performance 50Hz notch filter.The design method is relatively simple compared with other methods and the application result verifies its efficiency.
3.Application of Kalman filter to measurement of sound power for medical ultrasonic diagnostic equipment
Tiebing LIU ; Liming TANG ; Shitao QL ; Min WU ; Shujing SHEN
Chinese Medical Equipment Journal 1989;0(03):-
A data processing method for the sound power of the medical ultrasonic diagnostic equipment is introduced in this paper. The sound power for the transducer of a medical ultrasonic diagnostic equipment is measured for many times, and then the mathematical model based on the measurement data above is processed with Kalman filter.The output fluctuations for sound power of the equipment and its transducer as well as the measurement errors of sound power meter are eliminated to achieve the true value of sound power. Compared with other mean methods, the method above can improve the dicreteness of the measurements, and thus is worth being applied to processing other measured data.
4.Design of centralized infusion managing and controlling system
Shitao QI ; Liming TANG ; Tiebing LIU ; Min WU
Chinese Medical Equipment Journal 2003;0(10):-
This paper describes the structure, operating principles, design method of both software and hardware of a centralized controlling system of infusion pumps based on CAN bus. The system can monitor the status information and control the infusion parameters of many infusion pumps simultaneously. It provides a more complicated cliaical infusion treatment means, greatly eases the work burden on doctors and nurses, and promotes the effects of treatment and nursing.
5.Establishment of medical instrument quality & safety management system
Liming TANG ; Tiebing LIU ; Min WU ; Shitao QI
Chinese Medical Equipment Journal 2003;0(11):-
The development of medical technology and method more and more relies on medical engineering technology.This paper demonstrates the importance of quality management in medical engineering from many aspects,especially from the establishment of medical instrument quality and safety management system.
6.Principle and clinical application of ultrasonic surgical installation
Min WU ; Liming TANG ; Tiebing LIU ; Shitao QI ; Jie SHAO
Chinese Medical Equipment Journal 2003;0(10):-
With the appearance and development of ultrasonic surgical installation, ultrasonic therapy enters on a new epoch. High-amplitude and high-power ultrasonic vibration produced during the operation, ultrasonic surgical installation can be used to decrease the amount of bleeding or stop bleeding according to the acoustic properties of different tissues. The part where pathological changes happen can be excised selectively by ultrasonic surgical installation. This article introduces the principle, structure, classification and clinical application of ultrasonic surgical installation in detail.
7.Method for assessing bid of medical equipment based on BP neural network
Shitao QI ; Liming TANG ; Min WU ; Tiebing LIU
Chinese Medical Equipment Journal 2003;0(10):-
This paper introduces the basic theory of BP neural network and develops a model for assessing bid of medical equipment based on BP neural network. A case is analyzed with the model, and the result shows the high accuracy of it.
8.Study on requirement forecasting of medical consumptive materials based on Kalman filter
Tiebing LIU ; Liming TANG ; Jingjie YU ; Min WU ; Shitao QI
Chinese Medical Equipment Journal 2003;0(12):-
An analysis method for requirement of medical consumptive materials on Kalman filter is put forward.An analysis mathematical model is established at first,its solution process is carried out at same time,and then an example using this solution is given according to the working practice.At last,the shortcomings using classical Kalman filter were discussed and a new method using adaptive Kalman filter was proposed.
9.Study on measuring method for amplitude of transducer’s tip in ultrasonic surgical apparatus
Tiebing LIU ; Liming TANG ; Min WU ; Shitao QI
Chinese Medical Equipment Journal 1989;0(01):-
Objective To study the measuring method for amplitude of transducer's tip in ultrasonic surgical apparatus, and design a set of practical detecting system with special data processing technique. Methods The system was consisted of stereomicroscope, CCD camera, etc. The images of amplitude measuring were captured and processed and the result was carried out at last. Results The measurement range for amplitude of transducer’s tip was above 190 ?m, the precision was below 10?m, and the repeatability was also ideal. Conclusion The amplitude measuring method has some excellent characters such as directness, simplicity, easy implementation, error estimableness and controllability, etc. It is proved in practice that the effect is nice and the blank in this field in China is filled.
10.Development of Portable Battlefield Multifunction Diagnosis and Treatment Bed
Liming TANG ; Shitao QI ; Tiebing LIU ; Min WU ; Peng SUN
Chinese Medical Equipment Journal 1989;0(02):-
Objective To develop an improved product of the existing battlefield diagnosis and treatment bed by making the product smaller,the structure firmer,the function more perfect and the use more convenient,thus to benefit the use under the battlefield situations,and to improve the logistics support ability.Methods '08F,304'steel materials were adopted as prop-up parts of the bed.The fold type structure design,infusion shelf and mosquito net pole functions could be exchanged with each other.The special oxygen bottle clip was equipped.Results It had such advantages as lighter weight(half of the former),enlarged strength,diverse functions,simple operation and easy taking.As far as safety and reliability and operation flexibility concerned,it was far improved compared with the former one.The treatment bed met the requirement of diagnosis,treatment and nursing for patients under battlefield conditions.National patent of the product was declared.Conclusion The portable battlefield diagnosis and treatment bed is used under the field situation,so some more complicated structures and functions of the normal beds are omitted.Meanwhile,reasonable function combination and material and structure design are key factors in development.[Chinese Medical Equipment Journal,2008,29(2):10-11,14]