1.Near-infrared spectroscopic assessment of human hemoglobin dynamics associated with pressure stimulation applied by protrusion-lined innerware
Tatsuzo NAKAMURA ; Shigeru KAWAMURA ; Hirosi KITAKOJI ; Atsuko KAWAMURA ; Kenji IMAI ; Hideaki MATSUKUMA
Journal of the Japan Society of Acupuncture and Moxibustion 2010;60(2):234-243
(Object) We, in collaboration with Wacoal Corp., assessed the effects of human hemoglobin dynamics associated with pressure stimulus applied by half-ovoid protrusions lined on brassiere straps, which were developed with an intended use by females to safely alleviate shoulder stiffness and associated pain in a convenient manner, and compared them to those of conventional flat and round magnets (5 mm in diameter, 800 Gauss).
(Method) Six healthy females volunteered for each of the four experiments. The participants'thoracic circumference or band size was 70 cm (B70) for experiments one and two, and 80 cm (B80) for three and four. For experiments one and three, we obtained the control hemoglobin (Hb) values, by near-infrared spectroscopy, 20 minutes after participants had worn brassieres with the newly developed straps turned inside out;and were compared to the values obtained after the straps were worn with protrusions pressing down on the skin (Protrusion-lined Strap Group, PST). For experiments two and four, the control Hb values were obtained after the participants had worn generic brassiere straps, and were compared to Hb values obtained after the magnet-lined straps were worn (Magnet-lined Strap Group, MSG).
(Result) In the PSG (B70 &B80), both Oxy-Hb and Total-Hb values increased by stimulation with a 5%significant difference;however, no significant increase was observed in the MSG (B70 &B80). There was no significant difference depending on the band size.
(Discussion) In the present study, the post-stimulation increase of Hb values showed significant differences in PSG as a result of stimulation by protrusions. Stimulation by flat magnets demonstrated no such significance on Hb values, presumably due to the lower pressure to the skin. Stimulation by magnets showed no significant changes in total Hb values despite prior reports of it accelerating the blood flow. The shape with which pressure is applied against the skin may have relevance to the effect of stimulation.
Protrusions left post-stimulation depression marks and flare on the skin surface, suggesting the possible involvement of mechanothermal polymodal receptors.
(Conclusion) Stimulation with the protrusions we developed increased Hb values, showing a regional concentration of hemoglobin. This suggests that it is effective in alleviating shoulder stiffness and associated pain, and lining brassiere straps with the protrusions provides a means for females to self-apply such stimulation safely and conveniently.
2.Effects of spa bathing on blood coagulation and fibrinolysis.
Akira DEGUCHI ; Yoshiaki KARITANI ; Hitoshi HAMAGUCHI ; Toyomi MURASE ; Kouzou KAWAMURA ; Hideo WADA ; Katsumi DEGUCHI ; Shigeru SHIRAKAWA
The Journal of The Japanese Society of Balneology, Climatology and Physical Medicine 1989;52(2):73-78
Effects of hot bathing on blood coagulation and fibrinolysis were studied in 35 patients with various diseases by measuring pulse rate and blood pressure and performing peripheral blood and hemostatic examinations before and after a 10-minute hot bath at 40 to 42°C.
Pluse rate increased significantly during the hot bath (p<0.001) However, no changes were observed in the results of blood pressure and perpheral blood examinations.
APTT, PT, fibrinogen, factor II, V, VII, VIII, IX, X, XI, XII, von Willebrand factor, prekallikrein, and antithrombin III were measured during coagulation examinations, but no significant changes were observed between those factors before and after hot bathing.
Although no significant changes were shown in plasminogen and antiplasmin during hot bathing, euglobulin lysis time (ELT) was significantly (p<0.001) reduced during the hot bath. It remains to be determined whether the reduction in ELT is due to the release of a tissue-type plasminogen activator from the vascular endothelial cells.
The reduction rate of ELT was studied in patients with each type of disease. The reduction rate of ELT in the patients with hypertension (HT) was larger than that in the patients without HT, and that in the patients with cerebral vascular accident (CVA) was also larger than that in the patients without CVA. However, the reduction rate of ELT in the patients with diabetes mellitus (DM) was smaller than that in the patients without DM. The patients with CVA, HT or DM are considered to have vascular damages. In the effect of hot bathing on fibrinolysis, however, there is a difference in reduction rate of ELT between patients with HT or CVA and those with DM.
This study indicates that pulse rate is increased during hot bathing and fibrinolysis is accelerated.
3.Medical-Care and Social-Welfare Effectiveness of the Spa Community Home.
Akira DEGUCHI ; Masato NAKABAYASHI ; Hitoshi HAMAGUCHI ; Yoichi KAWAMURA ; Katsumi DEGUCHI ; Shigeru SHIRAKAWA ; Yukio NISHIMOTO
The Journal of The Japanese Society of Balneology, Climatology and Physical Medicine 1994;57(4):278-282