1.Determination of Aflatoxin B1 in Pharmaceutical Excipient Oil in Soft Capsules by LC-MS/MS
Sheng GAN ; Qingniao LAI ; Zhicheng LI ; Ting HAN ; Chaoquan WU
China Pharmacist 2016;19(2):244-246,247
Objective:To assay aflatoxin B1 in the oil as a pharmaceutical excipient in soft capsules by LC-MS/MS. Methods:Aflatoxin B1 was extracted from the peanut oil in soft capsules by the solvent composed of methanol and 0. 1% formic acid solution, and then centrifuged and the supernatant was purified by neutral alumina cartridges and tested after the concentration with the mobile phase consisting of methanol and 0. 1% formic acid solution with gradient elution at the flow rate of 0. 3 ml·min-1 . 25μl of the tested solu-tion was injected for the analysis at the column temperature of 30℃. Electrospray ionization ( ESI) source was applied and operated in the position ion mode. Multiple reactions monitoring ( MRM) mode was used to quantify the samples. Results:Aflatoxin B1 was in good linearity within the range of 0. 098-1. 960 μg·L-1(r=0. 999 5). The limit of detection was 0. 05 μg·L-1. The average sampling recovery was 97. 73% (n=6) with RSD of 4. 625%. Conclusion:The method is proved to be sensitive, accurate, specified and re-producible, which is referential for the assay of aflatoxin B1 in oily preparations.
3.Comparison of double-channel lfexible ureteroscopy and electronic lfexible ureteroscopy for lithotripsy
Tian LI ; Xun LI ; Yongzhong HE ; Minlong YANG ; Yufei YIN ; Ming SHENG ; Dehui LAI ; Weiqing YANG
China Journal of Endoscopy 2017;23(3):34-37
Objective To compare the efficiency and safety of double-channel flexible ureteroscopy and electronic flexible ureteroscopy.Methods From April 2007 to 2016 July, clinical data of 836 cases flexible ureteroscopic holmium laser lithotripsy were collected. All the patients were randomly divided into electronic lfexible ureteroscopy group (n = 427) and double-channel lfexible ureteroscopy group (n = 409), the operation time, success rate of surgery, complications, residual stone rate of the two groups were compared.Results The success rate of surgery was 92.5% and 83.6% of the two groups respectively, the difference was significant (P < 0.05); postoperative systemic inlfammatory response syndrome (SIRS) were occurred in 10 cases and 13 cases respectively, which were cured and the difference was not statistically significant (P > 0.05); the average operation time was (81.1 ± 7.9) min and (95.3 ± 7.6) min respectively, the difference was significant (P < 0.05); The formation of stone street of electronic lfexible ureteroscopy group and double-channel lfexible ureteroscopy group were 17 cases and 25 cases. The residual stone rate of electronic flexible ureteroscopy group and double-channel flexible ureteroscopy group were 6 cases and 8 cases, of them were cleared after extracorporeal shockwave lithotrips (ESWL). There were no difference between the two groups (P > 0.05).Conclusion Both double-channel lfexible ureteroscopy and electronic lfexible ureteroscopy are effective and safe therapeutic modalities. Electronic flexible ureteroscopy is better than double-channel lfexible ureteroscopy in success rate of surgery because of its high deifnition and lfexible operation.
4.The characteristics and value of ultrasonography in the diagnosis of thyroid microcarcinoma
Sheng CAI ; Yixiu ZHANG ; Jianchu LI ; Bo ZHANG ; Mengsu XIAO ; Wenbo LI ; Xingjian LAI ; Yuxin JIANG
Chinese Journal of Ultrasonography 2008;17(8):704-708
Objective To investigate the role of gray-scale sonography in the diagnosis of thyroid microcarcinoma(TMC).Methods The sonographic characteristics of 58 TMC and 61 benign thyroid nodules(≤1 cm)were retrospectively reviewed and compared with each other.The size,echogenicity,internal solid/cystic component,configuration,anteroposterior to transverse dimension ratio(A/T),margin,halo sign and calcification type of the nodules were studied.Statistical analysis was performed using the chi-square test.The sensitivity,specificity,positive predictive value,negative predictive value and accuracy of individual sonographic characteristics were calculated respectively.Results In ultrasonography,TMC manifested as marked hypoechoic in 48.3%,solid lesion in 98.3%,irregular-shape in 74.1%,irregular halo sign in 37.0%,with internal microcalcifications in 62.1%.There were significantly statistical differences between the benign and malignant nodules in those findings (P<0.001).However,there was no obviously statistical difference in the obscure margin.The sensitivity,specificity and accuracy were 86.2%,77.0% and 81.5% respectively when using marked internal hypoechoic echo,A/T≥1 and microcalcification as a new combined criterior.Conclusions The gray-scale sonographic findings between the small benign and malignant thyroid nodules(≤1 cm)are different.Combining these sonographic signs can significantly improve diagnostic value of TMC.
5.Quality evaluation and stability investigation of asarone submicro emulsion injection.
Hong-Jia LI ; Xiu-Jun LAI ; Wei LI ; Ting CHU ; Hui JIN ; Sheng-Jun MAO
China Journal of Chinese Materia Medica 2014;39(20):3945-3949
The content of the asarone submicro emulsion injection was determind by HPLC method, and thereby a quality evaluation method was established based on indexes of pH value, particle size, peroxide value, methoxy aniline values, free fatty acid, lysophosphatidylcholine, visible foreign substances, insoluble particle, sterility, bacterial endotoxin and impurities, etc. The results showed that the injection exhibited uniform physical appearance and all the products were in milkwhite liquid. The content of the three batches products were respectively 102.9%, 100.8%, 97.70% of the labeled amount, with mean particle size of 210-250 nm, and other indexes all met with the standards. The reserved samples showed no obvious change in terms of detection indexes and indicated good stability after the accelerated stability test and long-term stability for 12 months. The quality evaluation method established in this study could be applied to quality control and stability investigation of asarone submicron emulsion injection, which laid a basis for further clinical research and application.
Anisoles
;
chemistry
;
Chromatography, High Pressure Liquid
;
Drug Stability
;
Drugs, Chinese Herbal
;
chemistry
;
Emulsions
;
chemistry
;
Particle Size
;
Quality Control
6.Clinical observation on warm needling moxibustion plus acupoint sticking therapy for cervical radiculopathy
Xi-Bing YANG ; Li-Feng QIAN ; Lai-Hua SHEN ; Ji-Sheng LI
Journal of Acupuncture and Tuina Science 2019;17(2):137-140
Objective:To observe the clinical effect of warm needling moxibustion plus acupoint sticking therapy for cervical radiculopathy.Methods:A total of 120 cases were allocated into an observation group,a warm needling group and an acupoint sticking group according to the random number table,with 40 cases in each group.Cases in the observation group received warm needling moxibustion plus acupoint sticking therapy;cases in the warm needling group received the same warm needling moxibustion in the observation group;cases in the acupoint sticking group received the same acupoint sticking therapy in the observation group.The scores of Japanese Orthopaedic Association (JOA) and visual analog scale (VAS) were recorded before and after treatment.Results:The total effective rate was 95.0% in the observation group,versus 77.5% in the warm needling group and 75.0% in the acupoint sticking group (both P<0.05).Inter-group differences in JOA and VAS between the observation group and the other two groups were statistically significant (all P<0.05).Conclusion:Warm needling moxibustion plus acupoint sticking therapy is effective in treating cervical radiculopathy,and it can significantly alleviate pain and enhance clinical efficacy,and thus is worth clinical popularization.
7.Academic origin of round magnetic needle and standardization operation.
Yan-Ting CHENG ; Tian-Sheng ZHANG ; Li-Qiang MENG ; Rui-Qi SHI ; Lai-Xi JI
Chinese Acupuncture & Moxibustion 2014;34(7):705-708
The origin and development of round magnetic needle was explored, and the structure of round magnetic needle was introduced in detail, including the handle, the body and the tip of the needle. The clinical opera tion of round magnetic needle were standardized from the aspects of the methods of holding needle, manipulation skill, tapping position, strength of manipulation, application scope and matters needing attention, which laid foundation for the popularization and application of round magnetic needle.
Acupuncture Therapy
;
history
;
instrumentation
;
methods
;
standards
;
China
;
History, Ancient
;
Humans
;
Medicine in Literature
;
Needles
;
history
;
standards
8.Application of Navien catheter in intracranial aneurysm embolization
Degang WU ; Zhenbao LI ; Xintong ZHAO ; Niansheng LAI ; Jiaqiang LIU ; Bin SHENG ; Jinlong YUAN ; Xinggen. FANG
Chinese Journal of Cerebrovascular Diseases 2017;14(3):133-138
Objective To investigate the application technology and effect of Navien catheter in intracranial aneurysms embolization.Methods The clinical data of 15 patients with intracranial aneurysm treated with Navien catheter in Department of Neurosurgery of Yijishan Hospital Affiliated to Wannan Medical College from March to December 2016 were analyzed retrospectively. The extracranial segments of internal carotid arteries were seriously tortuous in all patients. The coaxial system was used during procedure. Whether the Navien catheter could be smoothly placed into the target artery or not was observed,and the coils or stent-assisted coils were used to embolize the intracranial aneurysms in the corresponding positions. The immediate embolization results were assessed by the Raymond grading. The intraoperative and postoperative complications were observed and the patients were followed up by imaging.Results All 15 patients had abnormal tortuosity of extracranial segments of internal carotid arteries. The Navien catheter was able to smoothly pass through the tortuous vessels and reach the desired position. The stent-assisted coil embolization was used in 9 patients,and the coil embolization was used in 6 patients. The success rate of the coil and stent placement technology was 100%. The stents were all accurately put in place without shift. According to the Raymond grading,the immediate embolization rate of aneurysms showed that 15 patients achieved Raymond gradeⅠ. One case developed internal carotid spasm during the procedure. The patient was improved after giving papaverine. Others did not have intraoperative complications,such as cerebral vasospasm,vascular dissection,in-stent thrombosis,and intraoperative aneurysm rupture. Five patients were followed up for 3 to 6 months with digital subtraction angiography (DSA). There was no recurrence of aneurysm and no in-stent stenosis and shift,No rebleeding or cerebral ischemia was observed.Conclusion Forpatients with severely tortuous in extracranial segments of internal carotid artery,using the Navien catheter may overcome artery tortuosity and other unfavorable factors of the patients and successfully reach the target vessel position,enable the embolization of intracranial aneurysms to be completed successfully.
10.A Modified Method for Isolating DNA from Fungus
Ying-Hui ZHANG ; Dong-Sheng WEI ; Lai-Jun XING ; Ming-Chun LI ;
Microbiology 1992;0(03):-
Genomic DNA of two fungi Thamnidium elegans and Umbelopsis isabellina were extracted with an amended Cetyltrimethyl Ammonium Bromide (CTAB) method. This modified method uses repeated freezing in liquid nitrogen and thawing with combination of shocking with glass beads to replace of the tra- ditional method. Quality and concentration of DNA extracted by the modified methodwere tested. Compared with the traditional method, higher yield and purity of genomic DNA were obtained with less amount ofmy- celium. The result indicted that this is a simple and highly efficient method, which is suitable to treat many samples at one time and for basic molecular experiments, such as restriction endonuclease reaction and PCR.