1.The Study of Orientations of Bilirubin and Biliverdin by Surface-enhanced Raman Spectroscopy
Hu Jun ; Fang Qing ; Sheng Rongsheng ; Xu Zhisan ; ZENG Yune
Chinese Journal of Analytical Chemistry 2001;29(5):507-510
The surface-enhanced Raman spectra of bilirubin and biliverdin were obtained.By the bands analysis of the spectra,the orientation of bilirubin and biliverdin on the surface of silver colloid was discussed.In such case,the bilirubin was adsorbed on the silver colloid particle with the two planar pyrromethenone groups intercalated into the globe silver colloid particle,however,the biliverdin might lie flat on the surface of silver colloid with syn-synsyn conformation.
2.THE USE OF 6-AMINOCAPROIC ACID (EACA) TO REDUCE POSTOPERATIVE BLEEDING FOLLOWING IN MITRAL VALVE REPLACEMENT
Zhenglong DU ; Zhusheng KUANG ; Rongsheng XIONG ; Zhigang WANG ; Yibo LIU ; Hongtao XIA ; Tao BAI ; Sheng DENG ; Fu ZHANG
Chinese Journal of Postgraduates of Medicine 2001;24(5):20-21
Objective To determine the effect of 6-aminocaproic acid (EACA) to reduce postoperation bleeding following in mitral valve replacement.Method 50 adult patients uddergoing mitral valve replacement was adopted a double-bisind randomized trial to be divided into two groups.Each group is 25 patients.The patients in control groups received NS,the ones in study groups received NS as same as control groups but added EACE 10 g by intravation.The bleeding amount in cavitas thoracis were recorded on the sixth,twenty-fourth postoperative hours and ACT was recorded as well.Results The bleeding amount in study groups on the sixth postoperative hours were (290.0±41.3) ml.On twenty-fourth postoperative hours were (336.3±81.3) ml.The bleeding amount in control groups on the sixth postoperative hours were (393.4±73.6) ml.On twenty-fourth postoperative hours were (450.0±79.6) ml.The bleeding amount in study groups were decreased significantly as compared with in control groups (P<0.05).Conclusion:6-aminocaproic acid can reduce postoperation bleeding following in mitral valve replacement.
3.C-arm hip fluoroscopy at primary position in the internal fixation of femoral neck fracture
Min CHEN ; Xiaohai FAN ; Jie ZHENG ; Kuangwen LI ; Shihao ZHANG ; Min LI ; Sheng LI ; Rongsheng CHEN ; Hongxun SANG
Chinese Journal of Orthopaedic Trauma 2020;22(5):445-449
Objective:To evaluate the hip C-arm fluoroscopy at primary position in internal fixation of femoral neck fracture.Methods:A retrospective study was conducted of the 69 patients with femoral neck fracture who had been treated from August 2015 to August 2018.They were divided into a primary position group ( n=35) subjected to C-arm hip fluoroscopy at primary position under symmetry traction of bilateral lower limbs for reduction of femoral neck fracture and a control group ( n=34) subjected to C-arm hip fluoroscopy at frog’s position on the healthy side for traction and reduction of the injured hip. The 2 groups were compared in terms of fluoroscopy frequency, times of resetting guide pin, intraoperative blood loss and total operation time. Results:The 2 groups were comparable due to insignificant significances between them in the preoperative general data like gender, age, fracture type, injury cause, or interval from injury to operation ( P>0.05). Compared with the control group, the primary position group showed less intraoperative fluoroscopy (7.2 times ± 0.5 times versus 16.1 times ± 1.2 times), fewer times of resetting guide pin (2.1 times ± 0.31 times versus 4.7 times ± 0.8 times), less intraoperative blood loss (96.8 mL ± 18.6 mL versus 198.1 mL ± 13.2 mL), and shorter total operation time (1.2 h ± 0.2 h versus 1.6 h ± 0.3 h). All the differences were statistically significant ( P<0.05). Conclusions:C-arm hip fluoroscopy at primary position may protect the stability after fracture reduction because bilateral lower limbs are under symmetrical traction and the hip position needs no alteration. Operation of C-arm fluoroscopy is easy and convenient and produces clear images. Therefore, this new mode of fluoroscopy has advantages of less intraoperative fluoroscopy and guide pin resetting, leading to significantly reduced intraoperative blood loss, ineffective operation time and anesthesia time.