1.Assessment of DSA dose effect with different combinations of parameters on brain organs:a phantom study
Shilong SUN ; Guijuan ZHOU ; Chuandong LI ; Yuli WANG ; Ruihong LIU ; Shaotian JIA ; Guosheng DU
Chinese Journal of Radiology 2016;50(6):455-458
Objective To investigate the lens and pituitary dose impacted by additional filtration and collection field in head and neck DSA examinations. Methods All images were acquired by a Philips ALLura Xper FD 20 DSA machine. The combination of the different collection fields (48 cm, 42 cm, 31 cm, 22 cm) and additional filtrations (0.9 mmCu+1.0 mmAl, 0.4 mmCu+1.0 mmAl, 0.1 mmCu+1.0 mmAl) were adjusted when the anthropomorphic phantom filled with dosimeter was scanned in anterioposterior and lateral positions with 2D?DSA and 3D?DSA. The dose area product (DAP), air kerma (AK) and the radiation dose values of bilateral lens and pituitary were measured and recorded. The 2D and 3D?DSA regional absorption dose on lens and pituitary were analyzed using t' test, the correlations between DAP and AK parameters and different regional absorption doses were evaluated by Pearson rank correlation coefficient. Results Absorption doses of left lens, right lens and pituitary with 2D?DSA (n=12) were as following:(2.77 ± 0.68), (6.23 ± 3.54), (8.65 ± 2.62) mGy, while the parameters with 3D?DSA (n=12) were (1.78 ± 0.82), (2.18±1.15), (3.32±0.64) mGy, respectively;the results revealed a significant difference (t'=3.20, 3.76 and 6.85, P<0.01). DAP [(8 739±5 731) mGy·cm2] had a relationship with absorption dose of pituitary, left lens and right lens [(5.988 ± 3.299),( 2.258 ± 0.872),( 4.207 ± 3.303) mGy, r values were 0.766, 0.684, 0.727; P<0.01]. AK values was (31 ± 23) mGy and it had a relationship with pituitary absorption dose (r value was 0.894, P<0.01). The lens dose was reduced when the additional filtration was increased and the collection field was decreased, the radiation dose of the pituitary was reduced when both the additional filtration and the collection field were increased. Conclusions In the head and neck DSA examinations, the radiation dose of the lens and the pituitary had different changes with the different additional filters and collecting fields. The organ dose with 3D?DSA was significantly less than that with 2D?DSA.
2.A REPORT OF TWO CASES OF INCOMPLETE REGRESSION OF VENTRAL MESOGASTRIUM
Hongdu ZHANG ; Guanliang LU ; Shujuan SHI ; Wen SHEN ; Ghanghan ZHANG ; Shaotian SUN ; Anrong ZHANG
Acta Anatomica Sinica 1953;0(01):-
Two cases of incomplete regression of ventral mesogastrium were reported. Their nomenclature, etiology, symptoms and characteristic roentgenologic findings were discussed in relation to anatomical study. Because of its unique etiology and symptoms, charecteristic roentgenologic findings, and effectual remedy, it is suggested that this disease should be distinguished from "abnormal adhesion of fibrous bands" as an independent anomaly called incomplete regression of ventral mesogastrium. The roentgenological findings were: An incisure was found in the upper portion of pars descendens duodeni. It sank deeply and reduced two thirds of the normal diameter of the intestinal lumen to form an eccentrie intestinal stenosis. The intestinal lumen, near the inner border of the incisure was smooth, and there was no sign of serrated image formed by intestinal mucosa. The part of intestinal lumen was not distended in hypotonic radiography. All the above signs were caused by the traction and binding of the nonregressed mesogastrium.