1.Reverse dot blot compared with hybrid capture 2 to detect human papillomavirus infection in cervix
Haiya WU ; Zheng ZHU ; Shaojuan WANG
Chinese Journal of Primary Medicine and Pharmacy 2008;15(3):359-360
Objective To evaluate the capacity of reverse dot blot(RDB)technique in screening Human papillomavirus infection in cervix.Methods 49 cases examined by hybrid capture 2(HC2)were collected for RDB technique testing.Results In the 49 cases,the positive of HR-HPV examined by HC2 was 89.8%(44/49),53.1%(26/49)by RDB,respectively.Sensitivity,specificity of RDB technique was 59.1%,100(5/5),conordance rate was 63.3%(31/49),positive predictive value and negative predictive value of RDB was 100%,21.7%,respectivdy.Kappa=0.23.Conclusion It is superior in the economy for screening human papillomavirus infection in cervix that RDB technique is developed and optimized,cheap RDB technique should be substituted for expensive HC2.
2.Radiology departments development in secondary hospitals and above in Shandong province
Yi ZHANG ; Shaojuan SONG ; Lebin WU
Chinese Journal of Hospital Administration 2010;26(8):625-628
Objective To study the development of medical imaging in Shandong province and identify existing problems. Methods 378 secondary hospitals and above were surveyed with questionnaires and other means for a general picture of their radiology departments. The survey covered medical imaging examinations, human resources and equipment configurations. Results The recent five years have found a rapid growth of a variety of medical imaging examinations, digital imaging in dominance, high-end equipments as the mainstream, sufficient staffing, shortage of high-level talents in these hospitals. Conclusion The medical imaging examinations should be regarded as justified and reasonable, the competence of hospital staff should be upgraded, and operation of medical imaging examinations should be normalized.
3.The value of high pitch technology of dual-source CT in postoperative follow-up of endovascular graft exclusion to aortic dissection
Shaojuan WANG ; Liwei WANG ; Lingquan LU ; Liping WANG ; Qianzhi WU
Journal of Practical Radiology 2015;(9):1535-1538,1543
Objective To evaluate the characteristics and the value of dual-source CT single-energy high pitch scanning technology in postoperative follow-up of endovascular graft exclusion to DeBakey Ⅲ aortic dissection.Methods All of 58 patients with endovas-cular graft exclusion to Debakey Ⅲ aortic dissection underwent dual-source CT checkup.30 patients (group A)were scanned with single-energy high pitch technology,voltage 120 kV,pitch 3.2;28 patients (group B)were scanned with dual-energy standard pitch technology,voltage 100 kV and 140 kV,pitch 1.0;both groups were used CareDose4D technology to automatically track the cur-rent.Image post-processing was completed at the workstation.The stent condition,endoleak and residual dissection were observed and analyzed.The differences of image quality and radiation dose between two scanning modes were compared.Results All of 58 cases,postoperative conditions to 9 cases were perfect,the proportion was 1 5.52%;43 cases were with distal residual dissection,the proportion is 74.14%;and 12 cases were accompanied with endoleaks,the proportion was 20.69%.The endoleaks manifestation in-cluded punctuate,band-like,and patchy high density around the stent in enhanced images.The difference of scan length between group A and group B was not statistically significant,the image quality of both groups met excellent standard .The acquisition time and effective radiation dose to group A were 1/4 and 56% of group B respectively.the differences of both groups were statistically significant.Conclusion Dual-source CT with single-energy high pitch scanning technology can ensure image quality and significantly reduce the effective radiation dose,it is a more advantageous scanning mode.
4.The effect of dezocine combined with sufentanil for analgesia sedation in patients undergoing thoracic surgery
Jinxiu ZHONG ; Shaojuan WU ; Kangqiang HUANG ; Hua WEI
Chongqing Medicine 2015;(30):4222-4223,4226
Objective To investigate the clinical effect of application of dezocine combined with sufentanil in patients under‐going thoracic surgery ,and discuss its security .Methods Selected 60 cases of patients undergoing thoracic surgery treatedn in the hospital from January to June 2013 ,then divided into two groups with 30 cases in each group randomly .ASA grade Ⅰ - Ⅱ ,the ob‐servation group took dezocine combined with sufentanil after the surgery ,the control group took sufentanil for analgesia ,then ob‐served the analgesia and sedative effect and the occurrence rate of adverse reaction between two groups of patients .Results The observation group′VAS pain score on postoperative 6 ,12 ,24 ,48 h were (3 .21 ± 0 .76)% ,(3 .01 ± 0 .77)% ,(2 .79 ± 0 .69)% , (2 .67 ± 0 .66)% and significantly better than the control group(P<0 .05);The observation group′Ramsay sedation score on post‐operative 6 ,12 ,24 ,48 h were (2 .12 ± 0 .23)% ,(2 .07 ± 0 .22)% ,(2 .02 ± 0 .24)% ,(2 .01 ± 0 .21)% ,the sedative effect was better than the control group(P<0 .05);48 h after the surgery the pressing times and effective analgesia pump frequency and adverse re‐action of the patients in the observation group were lower than that of the control group(P<0 .05) .Conclusion The effect for se‐dation and analgesia of dezocine combined with sufentanil in patients undergoing thoracic surgery is better and safe .
5.Evaluation of the teaching activity on the courses correlated with public health from the clinical medical students in Sun Yat-sen university
Xiangjun WANG ; Yuantao HAO ; Huiming ZHOU ; Shaojuan ZHAO ; Zhongdao WU
Chinese Journal of Medical Education Research 2015;(8):791-796
Objective To evaluate the teaching activity on public health courses from clinical medical students in our university in order to provide a scientific basis for improving the curriculum design and teaching reform. Methods The “Questionnaire on Teaching Evaluation in Public Health Courses”, including teaching attitude, teaching content, teaching methods and teaching effectiveness was designed, and a general investigation was conducted among the clinical medical students of five-year program (840 students) and eight-year program (278 students) in these three aspects to under-stand students' evaluation to the course, who had finished the public health courses, including Preven-tive Medicine, Medical Statistics and Epidemiology (hereinafter referred to as: statistics, epidemiology, prevention) in Sun Yat-sen University. Statistical analysis was made using SPSS 13.0 software. Data analysis methods contain descriptive analysis, T-test, ANOVA, LSD, SNK, hierarchical logistic regres-sion analysis, etc. Results The overall score of teaching evaluation is (4.04±0.60). Differences exist between the evaluation in the five-year medical students and the eight-year medical students. The P values were 0.000 (Medical Statistics), 0.269 (Epidemiology), 0.047 (Preventive Medicine). The com-parison of scores among the four dimensions shows: Teaching effectiveness < Teaching methods
6.The relationship between HLA typing,CREGs and early rejection after kidney transplantation
Shaojuan YANG ; Lijuan XUE ; Xiaodong WU ; Weizhong WANG
Chinese Journal of Immunology 2000;0(09):-
Objective:To study the relationship between human leukocyte antigen(HLA) typing, HLA crossreaction antigen group(CREGs) mismatching and early rejection after cadaver donor kidney transplantation.Methods:Donor and recipient HLA class Ⅰ typing was performed with Paul Terasaki monoclonal antibody tray and HLA class Ⅱ gene typing with Micro-sequence-specific-primers(Micro-SSP). PRA was detected by using Paul Terasaki mixture antigen tray.Results:The cases of 6, 5, 4, 3, 2, 1, 0 HLA mismatching(MM) in 131 recipients with negative PRA were respectively 0, 4, 26, 49, 33, 15, 4. The incidence of early rejection were 0,25%,23.1%,14.3%,12.1%,6.7%,0. No recipient with 5 and 6 CREGs MM. The case of 4,3,2,1,0 CREGs MM, the early rejection were respectively 28.6%,22.9%,9.5%,6.9%,5.5%.Conclusion:HLA typing and HLA crossreactive antigen group(CREGs) matching play an important role in selecting suitable donor, reducing early rejection, improving the effect of kidney transplantation.
7.The cloning,expression and purification of cDNA in E.coli
Xiaodong WU ; Lijuan XUE ; Shaojuan YANG ; Hui ZHU ; Weizhong WANG
Chinese Journal of Immunology 1986;0(04):-
Objective:The human heparin-binding growth factor Midkine(hMK) gene was constructed and expressed in E.coli, and the activity of MK protein was tested.Methods:The MK gene was amplificated from the tissue of human embryo kidney by RT-PCR techniques. The MK fragment without signal peptide was inserted into plasmid pET30a. The gene was expressed in E.coli, the protein was purificated by affinity chromatography, and the activity was tested by ~3H-TdR method.Results:The sequence of hMK in our experiment was as same as the sequence published in Genebank. The activity assay was shown high activity of MK protein in our experiment.Conclusion:The expression carrier of hMK was established successful and it can expression high activity hMK protein in E.coli.
8.Mutation of P53 tumor suppressor gene in colorectal cancer and its relationship with histologic grade and Dukes' stage
Zhifu HOU ; Shaojuan YANG ; Yuren WANG ; Xiodong WU ; Wenlan ZHANG ; Weizhong WANG ; Wei WANG
Journal of Jilin University(Medicine Edition) 1999;25(2):140-142
Objective :To study mutation of Ps3 gene and its relationship with histologic grade and Dukes' stage in colorectal cancer. Methods :PCR-SSCP was used to detect mutations of Ps3 in 30 colorectal cancer patients. Results: It was found that 6 mutations (20. 0%) in the coding region of P53 gene. One mutation was located in exon4; 5 mutations were located in exon 5; none of mutation was found in exon 2 and 3. According to the histologic grade of of colorectal cancer,the frequencies of P53 gene mutation were 1/8 (12. 5%) in the well differentiated and in the moderately differentiated as well,3/10 (30. 0%) in the poorly differenctiated and 1/4 (25.0%) in the undifferentiated. In clinic, the frequencies of P53 gene mutation were associated with Dukes stage: 1/10 (10. 0 % ) in B stage, 2/12 (16. 7%) in C Stage,3/8(37. 5%) in D stage. Conclusion:The mutation of P53 gene is related to Dukes' stage,and the P53 gene mutation hardly occurs in exon 2,3 in coloretal cancer.
9.Evaluation of radiation dosage in chest digital tomosynthesis
Dianxing ZHANG ; Lebin WU ; Yi ZHANG ; Jun TIAN ; Shaojuan SONG ; Ye TIAN
Chinese Journal of Radiology 2012;46(3):275-278
Objective To evaluate the feasibility of chest digital tomosynthesis(DTS)for lung lesion screening by comparing the effective dose of chest DTS with chest digital radiography(DR),low-dose MSCT and MSCT examinations.Methods The Fluke lung/chest phantom underwent posterior-anterior (PA),left lateral(LAT)chest DR and DTS with automatic exposure control technique.Using RTI DoseGuard and WinODS,the dose area product(DAP)and effective dose of PA,LAT and total DTS were calculated.CareDose technique was used for MSCT and low-dose MSCT scans,the dose length products (DLP)was acquired.According to the DLP to E(k)conversion coefficient in ICRP 103,the effective dose of low-dose MSCT and MSCT were calculated.Paired t test was used for comparison of the mean effective dose of DTS,DR and low-dose MSCT.Results The mean effective dose was 0.1 3 mSv for chest DR and 0.11 mSv for DTS examination.The mean effective dose of low-dose MSCT and MSCT scans were 1.13 mSv and 6.38 mSv.The effective dose of chest DTS was comparable to that of chest DR,and was approximately 1/10 and 1/60 times lower than that of low-dose MSCT and MSCT scans.There was no statistical difference between chest DTS and DR(t =3.514,P >0.01),and there was a significant difference between chest DTS and low-dose MSCT(t =178.769,P <0.01).Conclusion DTS is a new X-ray tomography which has the advantage of low radiation dosage in chest examination for lung lesion screening comparing with low-dose MSCT.
10.Applied Research of Extractive Reference Substance for the Quality Analysis of Fritillariae Thunbergii Bulbus Formula Granules
Haiyan CHEN ; Yin WU ; Shaojuan WU ; Mingde ZENG ; Jianyu ZHONG ; Jianchao ZHANG ; Dandan LIN ; Yirao ZHANG ; Longgang GUO
Traditional Chinese Drug Research & Clinical Pharmacology 2024;35(1):115-121
Objective To analyze the quality of 22 batches of Fritillariae thunbergii bulbus Formula Granules from 12 different manufacturers by using water-extraction reference substance of Fritillariae thunbergii bulbus(ZBM ERS ST)and water-extraction reference substance of Fritillariae hupehensis bulbus(HBBM ERS ST)as references.Methods Ethyl acetate-methanol-triethylamine-water(17∶1∶1∶0.5)was used as the developing solvent for high-performance thin-layer chromatography(HPTLC)fingerprint analysis.The high-performance liquid chromatography(HPLC)fingerprint analysis was performed on a Agilent Eclipse XDB-C18 column(4.6 mm×250 mm,5 μm)with the gradient mobile phase consisted of acetonitrile-0.03%diethylamine solution.The column temperature was set at 25℃and evaporative light-scattering detector was used.The determination was conducted according to standard test method for measurement of Fritillariae thunbergii bulbus Formula Granules(Guangdong PFKL00117).Results The results of HPTLC and HPLC analysis showed that there are significant differences among the 22 batches of Fritillariae thunbergii bulbus Formula Granules.There were 4 batches of Fritillariae thunbergii bulbus Formula Granules from 3 manufacturers among them showed fingerprint characteristics of Fritillariae hupehensis bulbus.The total amount of peimine and peiminine in the remaining 18 batches of Fritillariae thunbergii bulbus Formula Granules was 0.291-3.179 mg·g-1,which were quite different.Conclusion Currently,the quality of Fritillariae thunbergii bulbus Formula Granules on the market varies greatly.Standardized water-extract reference substance has better applicability for the analysis of the quality of Fritillariae thunbergii bulbus Formula Granules than the control medicinal materials.