1.Nevoid Hyperkeratosis of the Nipple and Areola in a Middle-aged Man.
Seung Joon OH ; You Chan KIM ; Seung Hun LEE
Korean Journal of Dermatology 2016;54(3):212-214
No abstract available.
Nipples*
2.A Case of Adrenal Cavernous Hemangioma.
Jeong Oh LEE ; Seung Hun JEON ; Yang Hoo KIM ; In Gon KIM ; In Gi SEONG ; Bo Hyun HAN
Korean Journal of Urology 2000;41(6):803-806
No abstract available.
Hemangioma, Cavernous*
3.Comparative Measurement of Skin Surface Hydration Using a Hydrometer and Corneometer.
Seung Hun LEE ; Joon CHUNG ; Sung Ku AHN ; Jin Soo KANG ; Oh Kyu KWON
Korean Journal of Dermatology 1994;32(4):599-608
BACKGROUND: Hydration, the water content of the stratum corneum, is an important factor in both the appearance and the barrier function of the skin. Many non-invasive methods have been developed in order to assesa the hydration state of the skin and the effect of various moisturizers. The hydrometer and carneometer are commercially available instruments which are widely used in dermatologic research. OBJECTIVE: Our purpose was to compare the measuring usefulnes of both instruments on normal subjects with a wide range of hydration states of the hornylayer. METHODS: We measured the conductance with the hydrometer and the capacitance with the corneometer in various hydrating eonditions and compared both insruments. RESULTS: Conductance had a non linear correlation with capacita ice. Capacitance measured with the corneometer had a high sensitivity to moisture in a wide range of hydration levels. On the other hand, conductance guaged with the hydrometer showed a few sensitivity to moisture at a low level. When the hydretion level was measured after a moiturizer was added, 10 % urea cream showed a sharp increase by 256% in terms of conductanae, and H-base by 97.8%. Mineral oil decreased by 41.5% and petrolatum by 62% respectively. On the other hand, when measured in terms of capacitance under the same conditions as above, 38.9 increase in 10% urea cream, 19.3% increase in H-base, 20% decrease in mineral oil, and 43.5 % decrease in petrolatum were reported. Conductance showed a higher hygroscopicity and a lower water holding capacity than capacitance did. When the measurement of the moisture level iri virious parts of the human body is performed, the corneometer provided us with more stable alies than the hydrometer. While the hydrometer can not the available and appropriate under the condition of insulation, the corneometer can measure moisture levels even down at the depth of 250mm. When measured after the oily surface of the forehead was cleansed with soft tissue, conductance and capacitance revealed higher values of moisture levels than before the eleanin. However, there is no statistical significance in these values. CONCLUSION: The hydrometer is a more appropriate tool for the measurement of moisture at a high level, and the corneometer at a low moisture level. The hydrcmeter is a more sensitive method of measuring the increase and the decrease in the moisture level.
Forehead
;
Hand
;
Human Body
;
Ice
;
Lasers, Gas
;
Mineral Oil
;
Petrolatum
;
Skin*
;
Urea
;
Water
;
Wettability
4.Comparative Measurement of Skin Surface Hydration Using a Hydrometer and Corneometer.
Seung Hun LEE ; Joon CHUNG ; Sung Ku AHN ; Jin Soo KANG ; Oh Kyu KWON
Korean Journal of Dermatology 1994;32(4):599-608
BACKGROUND: Hydration, the water content of the stratum corneum, is an important factor in both the appearance and the barrier function of the skin. Many non-invasive methods have been developed in order to assesa the hydration state of the skin and the effect of various moisturizers. The hydrometer and carneometer are commercially available instruments which are widely used in dermatologic research. OBJECTIVE: Our purpose was to compare the measuring usefulnes of both instruments on normal subjects with a wide range of hydration states of the hornylayer. METHODS: We measured the conductance with the hydrometer and the capacitance with the corneometer in various hydrating eonditions and compared both insruments. RESULTS: Conductance had a non linear correlation with capacita ice. Capacitance measured with the corneometer had a high sensitivity to moisture in a wide range of hydration levels. On the other hand, conductance guaged with the hydrometer showed a few sensitivity to moisture at a low level. When the hydretion level was measured after a moiturizer was added, 10 % urea cream showed a sharp increase by 256% in terms of conductanae, and H-base by 97.8%. Mineral oil decreased by 41.5% and petrolatum by 62% respectively. On the other hand, when measured in terms of capacitance under the same conditions as above, 38.9 increase in 10% urea cream, 19.3% increase in H-base, 20% decrease in mineral oil, and 43.5 % decrease in petrolatum were reported. Conductance showed a higher hygroscopicity and a lower water holding capacity than capacitance did. When the measurement of the moisture level iri virious parts of the human body is performed, the corneometer provided us with more stable alies than the hydrometer. While the hydrometer can not the available and appropriate under the condition of insulation, the corneometer can measure moisture levels even down at the depth of 250mm. When measured after the oily surface of the forehead was cleansed with soft tissue, conductance and capacitance revealed higher values of moisture levels than before the eleanin. However, there is no statistical significance in these values. CONCLUSION: The hydrometer is a more appropriate tool for the measurement of moisture at a high level, and the corneometer at a low moisture level. The hydrcmeter is a more sensitive method of measuring the increase and the decrease in the moisture level.
Forehead
;
Hand
;
Human Body
;
Ice
;
Lasers, Gas
;
Mineral Oil
;
Petrolatum
;
Skin*
;
Urea
;
Water
;
Wettability
5.Ultrasonographic Diagnosis of Congenital Hypertrophic Pyloric Stenosis.
Shin Heh KANG ; Chul LEE ; Ran NAMGUNG ; Dong Gwan HAN ; Ki Keun OH ; Seung Hun CHOI
Journal of the Korean Pediatric Society 1989;32(6):756-764
No abstract available.
Diagnosis*
;
Pyloric Stenosis, Hypertrophic*
6.A Case of Impetigo Herpetiformis during Pregnancy.
Seong Pil LEE ; Seong Jin HONG ; Su Mi OH ; Heung Gon KIM ; Seung Hun CHA
Korean Journal of Obstetrics and Gynecology 1999;42(8):1864-1868
Impetigo herpetiformis is a rare pustular eruption that may be seen in late pregnancy. It is associated with severe maternal and fetal complications in case of misdiagnosis and delayed treatment. The patient was a 25-years-old multigravida with psoriasis in her past history. At 20weeks gestation, she had been developed erythematous scaly annular patchs with papules and pustules on inner thigh. At 37weeks' gestation, the patient was suffered from a severely pruritic pustular rash with fever and leukocytosis. The skin of the affected areas was biopsied and showed intraepidermal pustular abscess with a neutrophilic infiltrate. Treatment commenced with intravenous fluids, antibiotics, systemic prednisone, steroid creams, and phototherapy(UVB) under the careful fetal well being monitoring. Cesarean section was done due to fetal distress, and a normal healthy male infant was delivered, following which the patient's condition improved rapidly.
Abscess
;
Anti-Bacterial Agents
;
Cesarean Section
;
Diagnostic Errors
;
Exanthema
;
Female
;
Fetal Distress
;
Fever
;
Humans
;
Impetigo*
;
Infant
;
Leukocytosis
;
Male
;
Neutrophils
;
Prednisone
;
Pregnancy*
;
Psoriasis
;
Skin
;
Thigh
8.Effect of continuous whole body hot bath on blood sugar level in diabetic rats treated with intermediate-acting insulin.
Sae Yoon KANG ; Seung Han YANG ; Sung Hun NAM ; Chan Seok OH
Journal of the Korean Academy of Rehabilitation Medicine 1991;15(4):412-416
No abstract available.
Animals
;
Baths*
;
Blood Glucose*
;
Insulin*
;
Rats*
10.Observation on the platelet activation in disseminated intravascular coagulation.
Kyung Soon SONG ; Seung Bok LEE ; Baik Soo KIM ; Oh Hun KWON ; Samuel Y LEE
Korean Journal of Hematology 1991;26(1):81-85
No abstract available.
Blood Platelets*
;
Disseminated Intravascular Coagulation*
;
Platelet Activation*