1.Clinical Efficacy of Digital Infrared Thermographic Imaging in Multiple Lumbar Disc Herniations.
Yong Eun CHO ; Young Soo KIM ; Ho Yeol ZHANG
Journal of Korean Neurosurgical Society 1998;27(2):237-245
Localization of the specific symptomatic level in multiple lumbar disc herniations is very important in the decision of surgical levels and operative method and is also one of the rate limiting factor for the successful postoperative results. Until now pain provocation test with discography is known as the unique functional and physiological method to localize the symptomatic level of disc herniation. But it is an invasive study and there is still an ongoing argument about discography for their diagnostic accuracy and specificity. Digital infrared thermographic imaging technique is a non-invasive technique to detect the discogenic pain with high accuracy. Authors evaluated the diagnostic efficacy of digital infrared thermographic imaging in 202 cases of multiple lumbar disc herniations by analysis of symptom correlation and the accuracy with operative findings. And also the correlation of digital infrared thermographic imaging technique with discography was analyzed. The digital infrared thermographic imaging technique showed high sensitivity(86.4%) to the clinical symptom and good correlation with the operative findings. It also revealed high correlation rate(81.4%) with discography. As a conclusion, digital infrared thermographic imaging technique is a highly effective diagnostic tool in the localization of the symptomatic level in multiple disc herniations.
Sensitivity and Specificity
2.Pelvic Ultrasonography Findings in Girls with Precocious Puberty.
Hyun Ju KANG ; Ji Sun NAM ; Won Kyoung CHO ; Kyoung Soon CHO ; So Hyun PARK ; Min Ho JUNG ; Gye Yeon LIM ; Byung Kyu SUH ; Byung Churl LEE
Journal of Korean Society of Pediatric Endocrinology 2010;15(2):126-132
PURPOSE: We analyzed pelvic ultrasonography (USG) findings in girls with central precocious puberty (CPP) and assessed the role of uterine and ovarian measurements in discriminating between CPP and other pubertal conditions. METHODS: Seventy-four girls (chronological age 7.8 +/- 0.5 years, bone age 9.9 +/- 0.8 years) with precocious pubertal signs were enrolled. Measurements of uterine and ovarian parameters by pelvic USG included antero-posterior diameters of the uterine fundus and cervix, diameter of each ovary, number of follicles, and maximal diameter of the largest follicle. The pelvic USG parameters were compared between girls with CPP (n = 49) and girls with atypical premature thelarche (PT) (n = 25). RESULTS: Antero-posterior diameter of uterine fundus (1.05 +/- 0.34 vs. 0.74 +/- 0.78 cm, P = 0.001), maximal ovarian diameter (2.13 +/- 0.48 vs. 1.84 +/- 0.74 cm, P = 0.048) and mean ovarian area (2.31 +/- 0.79 vs. 1.69 +/- 0.71 cm, P = 0.002) were significantly greater in girls with CPP than in girls with atypical PT. For the diagnosis of CPP, the sensitivity and specificity of A-P diameter of uterine fundus (> 0.9 cm) was 65.3% and 84.0%, the sensitivity and specificity of maximal ovarian diameter (> 2.0 cm) was 55.1% and 76%, and the sensitivity and specificity of mean ovarian area (> 2.0 cm2) was 62.9% and 80.0%. CONCLUSION: Girls with CPP had significantly higher dimensions of the uterus and ovary measurements compared to girls with atypical PT, but sensitivity and specificity were not high enough to differentiate CPP from atypical PT. Pelvic USG may help the diagnosis of CPP in girls.
Sensitivity and Specificity
3.Salmonella carriers among workers in food procesing and the antibiotic sensitivity of the species isolated at Hai Duong province.
Journal of Preventive Medicine 2000;10(4):74-76
In Hai Duong province, there was a case carrying salmonella with 31 S.typhi species isolated. 502 samples taken form workers, who are working in the food processing facilities and restaurants, were tested. The results showed that Salmonella was high sensitivity with cephalosporin and quinolone antibiotics. There was high resistance and multiresistant rate of this bacterium to common antibiotics.
Sensitivity and Specificity
;
Salmonella
4.Investigating the antibiotic sensitivity of bacteria isolated from Dong Da Hospital, Ha Noi city from June 2000 to June 2001.
Journal of Practical Medicine 2002;435(11):35-36
The bacteria most likely to cause hospital acquired infection are enteric those (35%), followed by S. aureus (25%), P. aeruginosa (13%) and S. pneumoniae (12.3%). S. aureus isolations have high rate of penicillin resistance, followed by chloramphenicol, ampicilline, cephalothine and oxacilline. P. aeruginosa has resisted to gentamycin and netilmycin and remains to be sensitive to amikacine, norfloxacine and ciprofloxacine. E. pneumoniae remains to be sensitive to most of test antibiotics, but it has resisted to chloramphenicol and penicillin. E. coli has high rate of resistance to ampicilline, cephalothine and chloramphenicol, but it remains to be sensitive highly to amikacin, netilmycin, gentamycin and tobramycin.
Bacterial Infections
;
Sensitivity and Specificity
5.Evaluation of Automated ESR Measuring system, SEDIsystem(TM).
Jung Ee LEE ; Kyung Dong KIM ; Chae Hoon LEE ; Chung Sook KIM
Yeungnam University Journal of Medicine 1996;13(1):110-115
The ESR is one of the oldest laboratory test still in use. Although it lacks specificity in diagnosis, it can be effective for monitoring disease activity and following-up. The Westergren method is used for reference method, however coefficient of variation has been described 0.8% to 22.9% according to the literature. Since the ESR was invented in 1921, measurement technique has developed and automated measurement is introduced. We analyzed one hundred forty-three patient samples using SEDIsystem' automated ESR measuring system and compared with modified Westergren and Wintrobe methods. Comparison between SEDIsystem' and modified Westergren for ESR measurement yields the following regression equation; y = 0.863x - 1.69 (r=0.830), SEDIsystem'M and Wintrobe y'= 1.14x - 14.7 (r=0.789), rcspectively. We repeated measurement to evaluate reliability, results are not significant in statistically. In conclusion, SEDIsysten' automated ESR measurement correlated with modified Westergren and Wintro" ; methods, reveal reliable results after 4 hours and can report rapidly for large samples. Thus, these results indicate that SEDIsystenT"' automated ESR measurement may be useful tool for clinical practice.
Diagnosis
;
Humans
;
Sensitivity and Specificity
6.Translation: Roadmap for Harmonization of Clinical Laboratory Measurement Procedures.
W Greg MILLER ; Gary L MYERS ; Mary Lou GANTZER ; Stephen E KAHN ; E Ralf SCHONBRUNNER ; Linda M THIENPONT ; David M BUNK ; Robert H CHRISTENSON ; John H ECKFELDT ; Stanley F LO ; C Micha NUBLING ; Catharine M STURGEON
Laboratory Medicine Online 2012;2(1):1-9
Results between different clinical laboratory measurement procedures (CLMP) should be equivalent, within clinically meaningful limits, to enable optimal use of clinical guidelines for disease diagnosis and patient management. When laboratory test results are neither standardized nor harmonized, a different numeric result may be obtained for the same clinical sample. Unfortunately, some guidelines are based on test results from a specific laboratory measurement procedure without consideration of the possibility or likelihood of differences between various procedures. When this happens, aggregation of data from different clinical research investigations and development of appropriate clinical practice guidelines will be flawed. A lack of recognition that results are neither standardized nor harmonized may lead to erroneous clinical, financial, regulatory, or technical decisions. Standardization of CLMPs has been accomplished for several measurands for which primary (pure substance) reference materials exist and/or reference measurement procedures (RMPs) have been developed. However, the harmonization of clinical laboratory procedures for measurands that do not have RMPs has been problematic owing to inadequate definition of the measurand, inadequate analytical specificity for the measurand, inadequate attention to the commutability of reference materials, and lack of a systematic approach for harmonization. To address these problems, an infrastructure must be developed to enable a systematic approach for identification and prioritization of measurands to be harmonized on the basis of clinical importance and technical feasibility, and for management of the technical implementation of a harmonization process for a specific measurand.
Humans
;
Sensitivity and Specificity
7.Using the Receiver Operating Characteristic (ROC) Curve to Measure Sensitivity and Specificity.
Korean Journal of Family Medicine 2009;30(11):841-842
No abstract available.
ROC Curve
;
Sensitivity and Specificity*
8.The Value of Ventriculoatrial Intervals in Determining the Mechanism of PSVT and the Sites of Accessory Pathways.
Kee Joon CHOI ; Kyoo Rok HAN ; Joo Hee ZO ; Hyo Soo KIM ; Cheol Ho KIM ; Dae Won SOHN ; Byung Hee OH ; Myoung Mook LEE ; Young Bae PARK ; Yun Shik CHOI ; Jung Don SEO ; Young Woo LEE
Korean Circulation Journal 1995;25(2):416-422
The ventriculoatrial(VA) intervals during supraventricular tachycardia(VAsvt) and during pacing with same cycle length as tachycardia(VApace) were analysed in 48 patients to evaluate the usefullness in determining the mechanism of paroxysmal supraventricular tachycardia(PSVT) and the sites of accessory pathways. The results are as follows : 1)In differenciation AV nodal reentry from AV reentry mechanism, VAsvt(25.6+/-21.5 vs 148.0+/-27.7msec, p<0.01), VApace-VAsvt(135.3+/-15.7 vs 55.0+/-33.5msec,p<0.01), and VAsvt/VApace(0.15+/-0.10 vs 0.75+/-0.14,p<0.05) were useful. Cutoff values were 95msec in VAsvt, 110msec in VApace-VAsvt and 0.5 in VAsvt/VApace. 2) There were no overlaps in VA intervals between the AV nodal reentry group and the AV reentry group with posteroseptal accessory pathway.3) In AV reentry tachycardia, VApace-VAsvt>50msec(sensitivity 81%,specificity 100%) and VAsvt/VAace<0.7(sensitivity 71%, specificity 100%) suggested the high probability of left free wall accessory pathway. In Conclusion, VAsvt, VApace-VAsvt and VAsvt/VApace are useful parameters in determining the mechanism of PSVT and the sites of accessory pathways.
Humans
;
Sensitivity and Specificity
;
Tachycardia
9.Comparison of the Usefulness of four Risk-of-Malignancy Indices using Ultrasonography in Ovarian masses.
Moo Sung JO ; Su Hyun MOON ; Jong Kil JOO ; Dong Soo SUH ; Ki Hyung KIM ; Man Soo YOON
Journal of the Korean Society of Medical Ultrasound 2010;29(3):157-164
PURPOSE: The aim of this study was to evaluate the usefulness of four Risk-of-Malignancy Indices (RMI) in women with ovarian masses. MATERIALS AND METHODS: Between January 2007 and December 2008, 344 women who visited our hospital for surgical exploration due to an ovarian mass were enrolled in this study. Each RMI was based on the combination of menopausal status, ultrasound findings of ovarian masses, and absolute level of serum CA-125. A cutoff level of 200 was chosen as the threshold for determining between malignant and benign ovarian masses in RMI 1, RMI 2, and RMI 3. A cutoff level of 450 was chosen as the threshold in RMI 4. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined. RESULTS: The combination of four malignancy indices is more accurate than menopausal status, ultrasound findings, and serum CA-125 alone, respectively for determining whether a mass is benign or malignant. RMI 1 and RMI 4 were found to be better than RMI 2 and RMI 3. RMI 4 was the most reliable test among them. The relationship between RMI 1 and RMI 4 was not statistically significant. With the cutoff level for RMI 4 at 450, the corresponding, sensitivity, specificity, positive predictive value, and negative predictive value were 72.1%, 88.0%, 56.4%, 93.9%, respectively. CONCLUSION: All four RMI were reliable tests for determining whether ovarian masses are malignant or benign, and RMI 4 was the most reliable index among them.
Female
;
Humans
;
Sensitivity and Specificity
10.A Comparision of Surepath(TM) Liquid-Based Smear with a Conventional Smear for Cervicovaginal Cytology-with Reference to a Histological Diagnosis.
Kyung Chul LEE ; Chan Kwon JUNG ; Ahwon LEE ; Eun Sun JUNG ; Yeong Jin CHOI ; Jong Sup PARK ; Kyo Young LEE
Korean Journal of Cytopathology 2007;18(1):20-28
This study was performed to compare Surepath(TM) liquid-based smear and a conventional cervicovaginal smear with reference to a histological diagnosis. A hybrid capture test (HCII) was also performed and analyzed. We collected matched cases for cervicovaginal cytology- histology: 207 cases for conventional cytology (CC) and 199 cases for liquid-based cytology (LBC). HCII was performed in 254 patients. When a cytological diagnosis of ASCUS or above (ASCUS+) is classified as positive and a histological diagnosis of LSIL+ is classified as positive, the sensitivity and specificity for LBC was 91.7% and 75.9%, respectively and the sensitivity and specificity for CC was 62.6% and 96.1%, respectively. When a cytological and histological diagnosis of LSIL+ is classified as positive, the sensitivity and specificity for LBC was 77.5 and 96.6%, respectively and the sensitivity and specificity for CC was 49.7% and 100%, respectively. When a histological diagnosis of LSIL+ is classified as positive, the sensitivity and specificity for HCII was 78.9% and 78.1%, respectively. The concordance ratio between the cytological and histological diagnosis was 80.4% (kappa=76.0) for LBC and 56.5% (kappa=55.1) for CC. LBC is more sensitive and less specific then CC, as a cytological cutoff level of ASCUS, but more sensitive and equally specific, as a cytological cutoff level LSIL or HSIL. LBC is more reliable with a high concordance ratio between the cytological and histological diagnosis.
Diagnosis*
;
Humans
;
Sensitivity and Specificity