1.Clinical study of transcervical occlusion of patent ductus arteriosus via femoral artery guided by ultrasound
Bao SUN ; Duan CHENG ; Bo LI ; Guibao HE ; Haifeng WANG ; Ahati ; Elias ; Xi SHENG ; Jinpeng LI ; Sadam ; Hussain
Journal of Chinese Physician 2018;20(5):701-703,708
Objective To evaluate the efficacy and safety of transthoracic echocardiography (TTE) guided by transcatheter closure of patent ductus arteriosus (PDA) through the femoral artery.Methods From February 2016 to December 2017,53 patients with simple PDA were selected,the funnel type in 30 cases,cast type in 23 cases.All patients were guided by TTE and transcatheter closure of PDA through the femoral artery.The femoral artery was guided by TTE by establishing the orbit of the femoral artery-catheter-pulmonary artery to the right ventricle.The right ventricular septal defect was placed under the femoral artery approach,and the therapeutic effect was evaluated by echocardiography after occlusion.The outpatient visits were made at 1,3,and 6 months after operation.Results PDA closure was successfully completed under TTE guidance in 53 patients.In one adult PDA,the ultrasonic diagnosis of the inner diameter of the catheter was incorrect due to the image quality,which resulted in the replacement of the occluded device several times,but the occlusion was successful.The operative time was (30 ± 10)min.And the back diameter of the transcatheter closure device was (12 ± 6) mm and the murmur of the transmission sheath disappeared.There was no shunt between the main pulmonary artery and the main pulmonary artery,and the length of hospitalization was 3-4 days.No shunt signal was found at 1,3 and 6 months follow-up.Left atrial diameter (LAD) [(25.8 ± 6.1) mm vs (30.6 ± 8.4) mm] and left ventricular end diastolic diameter (LVEDD) [(38.5 ±9.1)mm vs (45.2 ± 11.5)mm],were decreased significantly (P <0.05).Conclusions It is safe and effective to block PDA by using femoral artery approach under the guidance of TTE,which avoids the damage of X-ray and contrast agent,and its prospect of clinical application is promising.
2.Efficacy and safety of ultrasound-guided percutaneous retrograde closure of patent ductus arteriosus
SUN Bao ; CHENG Duan ; LI Bo ; HE Guibao ; WANG Haifeng ; Ahati Elias ; SHENG Xi ; LI Jinpeng ; Sadam Hussain
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2019;26(12):1208-1212
Objective To evaluate the efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with transthoracic echocardiography (TTE). Methods From February 2016 to November 2018, 98 patients of pure PDA were selected, including 43 patients of funnel type and 55 patients of tube type. There were 38 males and 60 females at age of 2-48 (9.8±10.4) years. All patients underwent TTE-guided retrograde closure of the PDA through the femoral artery to establish a femoral-abdominal aorta-thoracic aorta-ductus arteriosus-aorta-right ventricle trajectory.Under the guidance of TTE, a suitable closure umbrella was placed through the femoral artery. One month, 3 months, 6 months, 12 months after the surgery, the patients received out-patient clinical follow-up. Results Ninety eight patients were successfully occluded by TTE. The occluder was replaced many times in an adult PDA patient, but finally it was successfully plugged. The operation time was 33.2±5.8 min. The lumbar diameter was 12±6 mm. And the postoperative murmur disappeared. Ultrasound showed no shunt between the aorta and the pulmonary artery, and the postoperative hospital stay was 3-4 days. No shunt signal was found in 1, 3, 6, 12 months follow-up. Left atrial anteroposterior diameter (25.8±6.1 mm vs. 30.6±8.4 mm) and left ventricular end diastolic diameter (38.5±9.1 mm vs. 45.2±11.5 mm) were significantly smaller (P < 0.05). Conclusion TTE-guided transcatheter closure of PDA via femoral artery is a safe and effective method to avoid the damage of X-ray and contrast medium. The prospect of clinical application is good.