1.Pacilitaxel in association with gemcitabine for anthracycine-resistant advanced breast cancer
Qingfeng FANG ; Zhihua SHAO ; Wei LIN ; Jing JIN ; Yueyuan JIANG ; Ruiyuan LU
Chinese Journal of General Surgery 2001;0(10):-
Objective To evaluate the effect and safety of combined therapy of paclitaxel and gemcitabine for anthracycine(ANT)-resistant advanced breast cancer(ABC).MethodsFrom May 2000 to Aug 2004,twenty six patients with ANT-resistant ABC were treated with this combined regime.The median chemotherapy cycles were 2.5(range from 2 to 3 cycles).ResultsOf 26 patients, there were 3 complete(11.5%) and 11 partial(42.3%) responses for an overall response rate of 53.8%. Eight cases remained stable (30.8%) and 4 progressive (15.4%). The median survival time was 18 months. The median time to progression was 7 months. The main toxic reaction included bone marrow depression, liver function damage, alopecia, mucositis and peripheral neurotoxicity. ConclusionsCombined medication of gemcitabine and paclitaxel is effective in therapy of ANT-resistant advanced breast cancer with acceptable toxicity.
2.Automatic Detection System of ECG Performance Based on Single Channel ECG Recorder.
Wei HONG ; Lingfeng LU ; Ruiyuan YOU
Chinese Journal of Medical Instrumentation 2021;45(6):684-688
Aiming at the ECG performance indicators in the YY 0885-2013 "Medical electrical equipment Part 2: Particular requirements for the safety including essential performance of ambulatory electrocardiographic systems", the traditional detection methods are time-consuming and the test results are greatly affected by human factors. In this paper, an automated detection method is proposed. A set of automatic detection software for ECG performance is designed and developed based on a single-channel ECG recorder, and an automated detection system is set up in combination with standard testing equipment. And then, the MSA tool is used to analyze the repeatability and stability of the detection system, and the results show that the detection system is acceptable, and it can improve detection efficiency.
Electricity
;
Electrocardiography
;
Electrocardiography, Ambulatory
;
Humans
;
Software
3.Live cell fluorescent imaging and cytotoxicity assessment of pH fluorescent probe based on styrylcyanine dyes.
Lixia HUANG ; Xiang LIU ; Danting CUI ; Yikai XU ; Wenwei YOU ; Yichen YAN ; Xinwei LU ; Ruiyuan LIU
Journal of Southern Medical University 2014;34(11):1642-1645
OBJECTIVETo prepare a pH fluorescence probe based on styrylcyanine dyes for live cell imaging.
METHODSThe Probe 1 was prepared by reaction of 4-pyridinecarboxaldehyde with 1,1,2-trimethylbenz[e]indole. The influence of pH on the fluorescent properties was examined, and the cell viability was examined using cell counting kit-8. The Probe 1 was used as a pH fluorescence probe in living cell.
RESULTSProbe 1 emitted green fluorescence under neutral and basic conditions but orange fluorescence under acid condition. Probe 1 selectively stained the cytoplasmic regions of living cells without significantly affecting the cell viability.
CONCLUSIONThe pH-sensitive fluorescent probe prepared based on styrylcyanine possesses good ability of cell membrane permeation for live cell fluorescent imaging.
Cells, Cultured ; Fluorescence ; Fluorescent Dyes ; Hydrogen-Ion Concentration ; Optical Imaging