1.Hemodynamic analysis of real-time enhanced-ultrasonography in diagnosis of focal liver lesions
Wenping WANG ; Ruixue WEI ; Hong DING
Chinese Journal of Ultrasonography 2003;0(05):-
Objective To evaluate the value of real-time enhanced-ultrasonography (EUS) in the diagnosis of hepatic tumor. Methods Twenty-nine patients with 34 hepatic solid lesions were examined by real-time EUS,including 16 primary liver malignant tumors,4 metastatic liver tumors,5 focal nodular hyperplasias (FNH),and 9 hemangiomas. All the cases were confirmed by histopathology. The ultrasound unit (Esaote Megas) with real-time EUS technique was used. The contrast agent used was SonoVue (Bracco,Italy). Results After injection of SonoVue,all the lesions were variously enhanced on real-time ultrasonogram. A holistic inhomogeneous enhanced pattern with quick disappearing was mostly detected by real-time EUS in hepatic malignant tumors,a peripheral and centripetal enhanced pattern was mostly shown in hamangiomas,and a radial centrifugal enhanced pattern with homogeneity and quickly was observed in FNHs. If the lesions with enhancement in arterial phase and disappearing in portal phase after injection of SonoVue were regarded as a sign for malignant liver tumor,the sensitivity,specificity and accuracy in the diagnosis of liver cancer with real-time EUS were respectively 95%(19/20),100%(14/14) and 97% (33/34). Conclusions The dynamic enhanced fashions and various enhanced features in various hepatic tumors will be reflected by real time EUS,which improves the accuracy of ultrasonography in the diagnosis of liver tumors.
2.Role of contrast-enhanced color Doppler ultrasonography in diagnosis of focal hepatic lesions
Qing QI ; Wenping WANG ; Ruixue WEI
Chinese Journal of Ultrasonography 2003;0(07):-
Objective To investigate the diagnosis of hepatic tumors by contrast-enhanced color Doppler ultrasonography. Methods Thirty-two patients with known focal liver lesions(diameter 11-112 mm,mean 43 mm) were studied with color Doppler flow imaging(CDFI) before and after injection of 2.4 ml SonoVue at the concentration of 5 mg/ml. The pathological diagnosis included 13 benign lesions and 19 malignant ones. Analysis was performed on signal intensity of intratumoral vascularity,time of enhancement duration,resistant index and maximum velocity of intratumoral arterial blood flow. The data were compared between benign and malignant lesions. Results Before injection of SonoVue,intratumoral blood flow could be detected among 53.8 %(7/13) benign lesions and 78.9 %(15/19) malignant tumors. However these detection rates went up to 76.9 %(10/13) and 100%(19/19) respectively after administration of SonoVue. Significant difference between benign and malignant tumors was observed in time of enhancement duration. Furthermore RI showed significant difference between benign and malignant lesions.Diagnostic accuracy of hepatic tumors increased from 75.0 %( 24/32 ) to 90.6 %(29/32) after enhancement. Conclusions The clinical results showed the ability of contrast-enhanced CDFI in reflecting the blood supply of the hepatic tumors,demonstrating the high sensitivity and specificity of the technique,which could be of great value to the diagnosis of hepatic tumors.
3.Establishement of HPLC fingerprints of flavonoids in Ziziphi spinosae Semen and determination of two constituents
Xu YANG ; Ruixue RAN ; Wei SONG ; Wei QIAO
Chinese Traditional Patent Medicine 2017;39(5):989-992
AIM To establish the HPLC fingerprints of flavonoids in Ziziphi spinosae Semen and to determine the contents of two constituents.METHODS With spinosin as a reference peak,the HPLC fingerprints of ten batches of samples were established.The analysis of methanol extract of flavonoids in Ziziphi spinosae Semen was performed on a 30 ℃ thermostatic Agilent TC-C18column (4.6 mm × 250 mm,5 μm),with the mobile phase comprising of acetonitrile-0.1% acetic acid flowing at 1 mL/min in a gradient elution manner,and the detection wavelength was set at 280 nm.RESULTS There were ten common peaks in the HPLC fingerprints,eight of which (vicenin-Ⅱ,glucosylvitexin,isospinosin,spinosin,6'-pyridyloylspinosin,6'-p-hydroxybenzoylspinosin,6'-feruloylspinosin and 6'-p-coumaroylspinosin) were identified.Spinosin and 6'-feruloylspinosin showed good linear relationships within the ranges of 15.00-40.00 μg and 5.00-14.00 μg,whose average recoveries (RSDs)were 100.5% (1.6%) and 100.4% (1.6%),respectively.CONCLUSION This accurate,simple and reliable method can be used for the quality control of flavonoids in Ziziphi spinosae Semen.
4.Cloning and bioinformatics analysis of SBACT5 gene in Echinococcus multilocularis from Southern Qinghai Plateau
Shunwei HE ; Xiaoyan LI ; Hongqing LI ; Ruixue ZHAO ; Xiaoxing WEI
Journal of Medical Postgraduates 2017;30(8):818-823
Objective Sodium-bile acid cotransporter plays an important role in the development of Echinococcus.The present study aimed to clone sodium bile acid cotransporter gene in Echinococcus multilocularis (EmSBACT5) and to analyze the bioinformatics of its coding protein.Methods EmSBACT5 gene was amplified by reverse transcription RCR (RT-PCR) technology and its nucleotide sequence was sequenced.Bioinformatics softwares were used to predict and analyze the physical and chemical properties, hydrophilicity/hydrophobicity, transmembrane domain, post-translational modification sites, structural domain, secondary structure, tertiary structure, subcellular localization and biological functions of the coding protein.Results The complete open reading frame was amplified with 654 bp in length, encoding 217 amino acids.The homology of the nucleic acid sequence and amino acid sequence of EmSBACT5 gene were 98% and 96% with the published SBACT5 in Echinococcus granulosus (EgSBACT5) respectively.Protein analysis results showed that the molecular formula of EmSBACT5 protein was C1141H1797N273O284S11.Its relative molecular mass was 24240 and isoelectric point was 8.99.There were 9 post-translational modification sites and 4 typical domains.Alpha helical, β-sheet, β-turn and random coil accounted for 29.95%, 31.80%, 7.83% and 30.41%, respectively.This protein was a hydrophobic membrane protein and was mainly located in the cytoplasmic membrane, and it might play a role in the processes of material transport and signal transmission.Conclusion The EmSBACT5 gene was cloned successfully and the informatics characteristics of its coding protein were obtained, which provides basic information for prevention and control of echinococcosis.
5.Research progress of cell-free parasite DNA in the diagnosis of parasitic diseases
Shunwei HE ; Xiaoyan LI ; Ruixue ZHAO ; Yuan PENG ; Xiaoxing WEI
Chinese Journal of Zoonoses 2017;33(2):163-169
At present,corresponding cell-free parasite DNA molecules (CFPD) has been detected in serum,plasma,urine,saliva and other bodily fluids of a variety of the patients with parasitic diseases.Due to its high specificity and sensitivity,the CFPD shows a strong advantage of noninvasive diagnosis and continuous monitoring,etc.in parasitic diseases.This article namely reviews the current research of CFPD in the patients with parasitic disease at home and abroad in recent years,so as to provide new ideas for the development direction of parasitic disease diagnosis in the future.The current related problems are discussed in the mean time.
6.Gemstone Spectral CT Optimal Single Energy Imaging in Lower Extremity Angiography
Wei XIA ; Xusheng SONG ; Xiaorui YIN ; Ruixue LI ; Jingtao WU
Chinese Journal of Medical Imaging 2014;(11):842-845
Purpose To implement lower artery angiography in patients with peripheral arterial occlusive disease, and to investigate the feasibility of lower extremity gemstone spectral CT angiography in improving image quality.Materials and Methods Forty-eight patients suspected with lower extremity arterial occlusive diseases were randomly divided into research group and control group. Research group (24 cases) were carried out gemstone spectral CT angiography (CTA) scan and control group (24 cases) were scanned with multi-slice spiral CT (CTA). The CT value of the common iliac artery, popliteal artery and its branches was measured and contrast to noise ratio (CNR) were calculated in both groups. The images were evaluated independently by 2 senior physicians based on a 5-level evaluation standard.Results The CT value of common iliac artery, popliteal artery, anterior tibial artery and the CNR in research group were all higher than those in control group (t=8.7, 7.9, 12.6 and 17.2,P<0.01), but the background noise was lower than that in control group (t=1.5,P<0.01). The scores of two image quality accessed by physician 1 and 2 were 110:90 and 111:93 respectively with statistical difference (Z=-7.6 and-8.0, P<0.01).Conclusion The image obtained by gemstone spectral CT optimal single energy image technique is much better than that by conventional multi-slice spiral CT in lower extremity angiography.
7.Comparison of enhancement features of hepatic tumors on SonoVue-enhanced real-time gray-scale ultrasonography and contrast-enhanced helical CT
Ruixue WEI ; Wenping WANG ; Hong DING ; Qing QI ; Beijian HUANG
Chinese Journal of Ultrasonography 2003;0(10):-
Objective To compare enhancement features of hepatic tumors on SonoVue-enhanced real-time gray-scale ultrasonography and contrast-enhanced helical CT.Methods SonoVue-enhanced real-time gray-scale ultrasonography and contrast-enhanced helical CT were performed on 49 patients with 54 focal liver lesions,including 29 primary liver carcinomas,4 metastatic liver tumors,11 hepatic carvernous hemangiomas,7 focal nodular hyperplasias,2 focal fatty sparing,1 cirrhotic.Results Contrast-enhanced ultrasonography and helical CT showed consistent results in demonstrating hemodynamics of hepatic tumors.In the differentiating of malignant tumors and benign tumors,the sensitivity,specificity and accuracy of contrast-enhanced ultrasonography were(90.9)%(30/33),(90.5)%(19/21) and(90.7)%((49/54)),respectively.Those of contrast-enhanced CT were(90.9)%(30/33),(95.2)%(20/21) and(92.6)%((50/54)),respectively.Conclusions Both of the two imaging methods are valuable for differential diagnosis of liver tumors.
8.The swallowing center-insula cortex activation evoked by stimulating acupoints of lower extremity: a study using functional magnetic resonance imaging
Pengxu WEI ; Ruixue BAO ; Tong ZHANG ; Jing ZHANG ; Zuting ZHANG ; Mingxin JING
Chinese Journal of Physical Medicine and Rehabilitation 2011;33(12):898-901
Objective To investigate insula cortex activation evoked by stimulating different acupoints of lower extremity.Methods Twenty healthy male right-handed subjects were recruited to receive functional magnetic resonance imaging(fMRI)examination with a whole-body 3T Siemens Trio system for whole-brain imaging.Participants were at rest during scanning and were instructed to relax with their eyes closed,without falling asleep.A blockdesigned method was applied for acupoint stimulation.The examined acupoints on the right lower extremity were stimulated,respectively,resulting in 4 experimental conditions.Stimulation was performed by brushing the subject's skin over each acupoint with a sponge at a frequency of approximately 2 Hz.Images were analyzed using SPM5 software package.Group analysis was performed with the mixed-effects model.Small volume correction was used to investigate insula cortex activation under each condition at a threshold of P < O.01,with a 6-mm radius centered on the local maxima of activation in insula cortex.The scope of insula cortex was determined with SPM anatomy toolbox.Results All the examined acupoints induced activation in contralateral insula cortex.Activation clusters evoked by different acupoints presented various types of locations and shapes,and all of them located in the posterior part of insula cortex.Activation in the ipsilateral insula cortex was not found for all examined acupoints.Conclusions Stimulating lower extremity acupoints can activate posterior insula cortex.This effect may promote the recovery of dysphagia via several mechanisms including facilitating the initiation of swallowing,improving oral and pharyngeal sensation,and reducing taste disturbance.
9.Comparative study on hemodynamics features of recurrent hepatocellular carcinoma between contrast-enhanced ultrasonography and contrast-enhanced MRI
Ruixue WEI ; Wenping WANG ; Xiuzhong YAO ; Hong DING ; Beijian HUANG ; Feng MAO
Chinese Journal of Ultrasonography 2012;(11):953-956
Objective To compare the hemodynamics features of recurrent hepatocellular carcinoma between contrast-enhanced ultrasonography (CEUS) and contrast-enhanced MRI (CEMRI).Methods Forty three recurrent hepatocellular carcinoma lesions in 39 patients were evaluated by CEUS and CEMRI.All lesions were proved by operation or needle biopsy.The dynamic enhancement and washout process on CEUS and CEMRI were analyzed.Results On both two methods,all lesions showed hyperenhancement.Among which,30.2% (13/43) lesions showed hyperenhancement during arterial phase and no washout was found during portal venous phase,37.2 % (16/43) lesions hyperenhanced during arterial phase and washout during portal venous phase.During late phase,the enhancement of 60.5% (26/43) lesions decreased and 7.0% (3/43) lesions showed no washout on CEUS or CEMRI.The overall concordance ratio between two methods was 67.4% (29/43).Difference of hemodynamics features between CEUS and CEMRI was not statistically significant.Conclusions CEUS can accurately display the hemodynamic features of recurrent hepatocellular carcinoma,and enjoy high consistence with CEMRI.
10.Predicting acute rejection in transplanted liver with virtul touch tissue quantification technique: a preliminary study
Hong HAN ; Zhengbiao JI ; Hong DING ; Hui ZHANG ; Wenping WANG ; Ruixue WEI
Chinese Journal of Ultrasonography 2012;21(5):390-393
Objective To investigate the viability of virtual touch tissue quantification (VTQ)technique in the prediction of acute rejection in transplanted liver.Methods One hundred and eighteen patients enrolled in the study were categorized into four groups:normal control (n =31),cirrhosis ( n =29),transplanted liver with acute rejection (n =28),transplant liver without any complications (n =30).All the patients were confirmed by pathology or clinical results.The VTQ of right robe of liver was obtained by a ultrasound system with VTQ technique and the data was compared among the four groups.Results The VTQ was (1.10 ± 0.29)m/s,(1.33 ± 0.33) m/s,(1.81 ± 0.47) m/s and (2.12 ± 0.59) m/s in normal control,transplanted liver without any complications,transplanted liver with acute rejection and cirrhosis group,respectively.It was significantly different in all four groups (P<0.01).Patients with acute rejection were associated with the increase of the VTQ values (P<0.01).Using a cutoff of VTQ>1.36 m/s measured in the transplanted liver for prediction of acute rejection,the sensitivity and specificity were 82.1% and 68.2%.Conclusions VTQ technique may have some clinical value in evaluation the acute rejection in transplanted liver.