1.Comparison of enhancement features of hepatic tumors on SonoVue-enhanced real-time gray-scale ultrasonography and contrast-enhanced helical CT
Ruixue WEI ; Wenping WANG ; Hong DING ; Qing QI ; Beijian HUANG
Chinese Journal of Ultrasonography 2003;0(10):-
Objective To compare enhancement features of hepatic tumors on SonoVue-enhanced real-time gray-scale ultrasonography and contrast-enhanced helical CT.Methods SonoVue-enhanced real-time gray-scale ultrasonography and contrast-enhanced helical CT were performed on 49 patients with 54 focal liver lesions,including 29 primary liver carcinomas,4 metastatic liver tumors,11 hepatic carvernous hemangiomas,7 focal nodular hyperplasias,2 focal fatty sparing,1 cirrhotic.Results Contrast-enhanced ultrasonography and helical CT showed consistent results in demonstrating hemodynamics of hepatic tumors.In the differentiating of malignant tumors and benign tumors,the sensitivity,specificity and accuracy of contrast-enhanced ultrasonography were(90.9)%(30/33),(90.5)%(19/21) and(90.7)%((49/54)),respectively.Those of contrast-enhanced CT were(90.9)%(30/33),(95.2)%(20/21) and(92.6)%((50/54)),respectively.Conclusions Both of the two imaging methods are valuable for differential diagnosis of liver tumors.
2.Latissimus dorsi musculocutaneous flap for repairing severe soft tissue defect of the elbow
Weixiong HUANG ; Mingyue WANG ; Peng JI ; Ruixue WANG
Chinese Journal of Postgraduates of Medicine 2015;38(1):23-25
Objective To explore the effect of latissimus dorsi musculocutaneous flap for repairing severe soft tissue defect of the elbow.Methods Seventeen patients with severe soft tissue defect of the elbow were repaired by latissimus dorsi musculocutaneous flap.Ten patients were performed transfer of skin flap for functional reconstruction,9 patients reconstructed elbow flexion,and 1 patient reconstructed elbow extension.Seven patients' tissue defect were repaired by cover type musculocutaneous flap,and the areas of these flaps ranged from 6 cm × 10 cm-12 cm × 27 cm.Results All the musculocutaneous flaps kept alive.After an average postoperative follow-up for 12-40(22.0 ± 9.6) months,the color and luster of the flaps were satisfying.There were no scar contracture of the flap and no bulkiness of the elbow.Ten patients performed transfer of skin flap for functional reconstruction,and the range of motion was 100°-140° of flexion and-20°-0° of extension.Muscle power was M3-M5.Hand function was near normal.Conclusion Latissimus dorsi musculocutaneous flap is an ideal surgical method to repair the severe soft tissue defect of the elbow.
3.Accuracy and safety of digital image navigation aid module for thoracic pedicle screw placement in children
Lin HUANG ; Long WANG ; Ruixue CHENG ; Linjing ZHAO ; Zhenmei WANG
Chinese Journal of Tissue Engineering Research 2016;20(39):5840-5845
BACKGROUND:Pedicle screw fixation has been used in children with thoracic injury. Conventional method is screw implantation by hand. This method can meet the needs of surgery, but its accuracy was low, and incidence of complications was high. The application of digital image navigation aid module is possible. OBJECTIVE:To study accuracy and safety of digital image navigation aid module in thoracic pedicle screw placement. METHODS:Eight thoracic vertebral bodies were equal y and randomly assigned to the manual insertion group and the digital image navigation aid module group. Manual insertion group received manual screw insertion. In the digital image navigation aid module group, navigation aid module was made according to CT scan results combined with principle of reverse engineering and rapid prototyping. Pedicle screw was placed using the digital image navigation aid module. RESULTS AND CONCLUSION:(1) Success rate of once screw set was significantly higher in the digital imaging navigation aid module group than in the manual insertion group (P<0.05). (2) Twenty-eight screws were implanted in the digital image navigation aid module group and manual insertion group separately. The excellent and good rate of screw placement was 96%in the digital image navigation aid module group and 75%in the manual insertion group (P<0.05). (3) These findings suggested that digital image navigation aid module can effectively improve the success rate of pedicle screw insertion. Moreover, this method is simple, easy to operate, and can make a personalized nail placement program for each child.
4.Hemodynamics of hepatic focal nodular hyperplasia with contrast-enhanced ultrasonography
Wenping WANG ; Peili FAN ; Ruixue WEI ; Hong DING ; Beijian HUANG ; Zhengbiao JI ; Chaolun LI
Chinese Journal of Ultrasonography 2010;19(1):21-24
Objective To investigate enhancement appearance of hepatic focal nodular hyperplasia(FNH) at real-time gray-scale contrast enhanced ultrasonography(CEUS),and evaluate the value of CEUS in the diagnosis of FNH. Methods Thirty-four patients (36 lesions) with histologically proved FNH were examined by ultrasonography. Appearance on conventional ultrasonography and the enhancement pattern on CEUS were investigated. Results Thirty-six lesions were mostly hypoechoic.39% (14/36) of lesions had peripheral hypoechogenic circle. Color Doppler flow imaging showed a asteroid-like or spoke-and-wheel pattern in 65% (20/ 31) of lesions.Three enhancement patterns were observed in the early arterial phase: whole-enhancement pattern (28%, 10/36), gushing-spring enhancement pattern (44%, 16/36), and spoke-and-wheel enhancement pattern (28%,10/36).The frequency of central scar on CEUS was 17% (6/36), and detection rate of central scar by CEUS compared with pathology was 40% (6/15).Regarding one of the features (gushing-spring enhancement, spoke-and-wheel enhancement and scar) as standard of FNH, the coincidence of CEUS in this group was 78% (28/ 36) ,which was significantly higher than that of conventional ultrasonography 28% (10/36).Conclusions CEUS can be as a important method for diagnosing FNH.
5.Application of contrast-enhanced ultrasonography in the diagnosis of hepatic artery complications after liver transplantation
Hong HAN ; Wenping WANG ; Beijian HUANG ; Hong DING ; Ruixue WEI ; Yunhua ZHANG ; Hui ZHANG
Chinese Journal of Ultrasonography 2009;18(1):46-48
Objective To evaluate the value of contrast-enhanced ultrasonography(CEUS)in the diagnosis of hepatic artery complications after liver transplantation.Methods Thirty-seven patients suspected of hepatic artery complications were examined by CEUS.Contrast agent was SonoVue and low mechanical index harmonic CEUS was performed.Results CEUS helped significantly improve flow visualization in hepatic artery(100%).After contrast agent injection,mean contrast material arrival time was(16.1±5.5)s in hepatic artery and(19.3±4.6)s in portal vein.The diagnostic accuracy of hepatic artery thrombosis(HAT)was improved from 86%(30/35)to 100%(35/35)with CEUS.In the HAT group,contrast material arrival time in portal vein was(13.6±4.6)s,shorter to that in group without HAT(P<0.05).Hepatic artery pseudo-aneurysm was also showed in 2 patients with CEUS after liver transplantation.Conclusions CEUS is a useful technique in improving hepatic artery visualization,which contribute to diagnose hepatic artery complications after liver transplantation.
6.Comparison of enhancement features of primary hepatocellular carcinoma and recurrent hepatocelluar carcinoma on contrast-enhanced ultrasonography
Ruixue WEI ; Wenping WANG ; Hong DING ; Beijian HUANG ; Chaolun LI ; Hong HAN ; Zhengbiao JI
Chinese Journal of Ultrasonography 2010;19(9):773-775
Objective To compare enhancement features of primary hepatocellular carcinoma(PHCC)and recurrent hepatocellular carcinoma(RHCC) on.contrast-enhanced ultrasonography(CEUS). Methods CEUS was performed in 56 patients with 70 RHCC and 83 patients with 93 PHCC. The enhancement features of these two groups of hepatocellular carcinoma were compared. The time used for the enhancement material to arrive the lesion(Ta ), that used for the lesion to become isoechoic(T1 ) and hypoechoic relative to the surrounding hepatic parenchyma(To) were analyzed. The echogenicity change between the lesion and the parenchyma was observed during arterial phase,portal phase and delayed phase. Results The time used for the lesion to become hypoechogenicity of RHCC and PHCC was (104.0 ± 51.8)s, (85.5 ± 43.0)srespectively,there was significant difference between the two groups( P = 0.010). There were 24 (34.3 % )cases of RHCC and 16 ( 17.2% ) cases of PHCC becoming isoechoic during portal phase,the former rate was significantly higher than the later one( P = 0. 012). Conclusions There is significant difference between PHCC and RHCC in the performance of CEUS,this is useful for the early diagnosis of RHCC.
7.Development of an LC-MS/MS method for the quantitation of deoxyglycychloxazol in rat plasma and its application in pharmacokinetic study$
Rongshan LI ; Ruixue RAN ; Quansheng LI ; Yurong HUANG ; Yuan GU ; Duanyun SI
Journal of Pharmaceutical Analysis 2016;6(3):184-189
Deoxyglycychloxazol (TY501) is a glycyrrhetinic acid derivative which exhibits high anti-inflammatory activity and reduced pseudoaldosteronism compared to glycyrrhetinic acid. In this study, a sensitive and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was established for the quantitation of TY501 in rat plasma. Plasma samples were treated by precipitating protein with methanol and supernatants were separated by a Symmetry C8 column with the mobile phase consisting of me-thanol and 10 mM ammonium formate (containing 0.1%of formic acid) (90:10, v/v). The selected reaction monitoring (SRM) transitions were performed at m/z 647.4-191.2 for TY501 and m/z 473.3-143.3 for astragaloside aglycone (IS) in the positive ion mode with atmospheric pressure chemical ionization (APCI) source. Calibration curve was linear over the concentration range of 5–5000 ng/mL. The lower limit of quantification was 5 ng/mL. The mean recovery was over 88%. The intra-and inter-day precisions were lower than 6.0% and 12.8%, respectively, and the accuracy was within 71.3%. TY501 was stable under usual storage conditions and handling procedure. The validated method has been successfully applied to a pharmacokinetic study after oral administration of TY501 to rats at a dosage of 10 mg/kg.
8.Determination of the Entrapment Efficiency and Drug Loading Capacity of Curcumin and Quercetin Loaded Self-microemulsifying Drug Delivery System
Ruixue HUANG ; Yijun LI ; Yuwei MAO ; Lehuan LIU ; Jianhong WANG ; Jiaqi YU ; Jundong DAI
China Pharmacist 2017;20(4):664-667
Objective:To establish an HPLC method to determine the entrapment efficiency (EE) and drug loading (DL) of curcumin (CUR)and quercetin (QUE)loaded self-microemulsifying drug delivery system.Methods:A centrifugation method was used to isolate the free drug.The content of drug was determined by HPLC.The analytical column was a Purospher STAR LP C18 column (250 mm×4.6 mm,5 μm) and the column temperature was 30 ℃.The mobile phase was acetonitrile-4% acetic acid (50∶50) and the flow rate was 1.0 ml·min-1.The UV detection wavelength was set at 370 nm and the injection volume was 10 μl.Results:CUR and QUE were linear within the range of 10.728-96.552 μg·ml-1 (r=0.999 8) and 1.08-9.72 μg·ml-1 (r=0.999 9),respectively.The average recovery was 99.98%(RSD=1.46%,n=9) and 100.34%(RSD=1.06%,n=9),respectively.In CUR-QUE-SMEDDS,the EE of curcumin and quercetin was (95.97±0.50)% and (95.91±2.52)%,and the DL was (25.82±0.15) mg·g-1 and (1.80±0.05)mg·g-1,respectively.Conclusion:The method is accurate,rapid and simple,and suitable for the determination of DL and EE in CUR-QUE-SMEDDS.
9.Comparative study on hemodynamics features of recurrent hepatocellular carcinoma between contrast-enhanced ultrasonography and contrast-enhanced MRI
Ruixue WEI ; Wenping WANG ; Xiuzhong YAO ; Hong DING ; Beijian HUANG ; Feng MAO
Chinese Journal of Ultrasonography 2012;(11):953-956
Objective To compare the hemodynamics features of recurrent hepatocellular carcinoma between contrast-enhanced ultrasonography (CEUS) and contrast-enhanced MRI (CEMRI).Methods Forty three recurrent hepatocellular carcinoma lesions in 39 patients were evaluated by CEUS and CEMRI.All lesions were proved by operation or needle biopsy.The dynamic enhancement and washout process on CEUS and CEMRI were analyzed.Results On both two methods,all lesions showed hyperenhancement.Among which,30.2% (13/43) lesions showed hyperenhancement during arterial phase and no washout was found during portal venous phase,37.2 % (16/43) lesions hyperenhanced during arterial phase and washout during portal venous phase.During late phase,the enhancement of 60.5% (26/43) lesions decreased and 7.0% (3/43) lesions showed no washout on CEUS or CEMRI.The overall concordance ratio between two methods was 67.4% (29/43).Difference of hemodynamics features between CEUS and CEMRI was not statistically significant.Conclusions CEUS can accurately display the hemodynamic features of recurrent hepatocellular carcinoma,and enjoy high consistence with CEMRI.
10.Transplantation of fibula composite tissue flap to the repair of forearm bone and soft tissue serious defect
Weixiong HUANG ; Mingyue WANG ; Yueli YANG ; Xinlong ZOU ; Ruixue WANG ; Cunlin LIU
Chinese Journal of Microsurgery 2013;(3):237-240
Objective To investigate the effect of free transplantation of fibula composite tissue flap to the repair of forearm bone and soft tissue serious defect.Methods Eleven cases of reparing forearm bone and soft tissue serious defect through transplantation of free fibula composite tissue petal were applied from March 2004 to February 2011.The length of transplanted fibula composite tissue flap was 8-14 cm ; the flap area was 5 cm ×8 cm-20 cm ×20 cm.The curing situation on bone fracture was observed in 3,6 and 12 months after the surgical opration and the function of defected arm was evaluated in 1 year after surgical operation.Results All of 11 cases of fibula composite tissue flap were survived.The observation was undertaken for more than 12 months after the operation and the fracture section occured the characteristics of healing up in 3 months and fibula and arm bone occured well healed up in half a year; It scored 22.9 according to Enneking system after 1 year of the operation.The function of forearm rotation were classed as this:3 good cases,6 medium cases and 2 poor cases.In the 2 sural nerve bridging transplantation cases,one case was repaired of radial nerve inside static's two-point discrimination (s2PD) to 9 mm,another case was repaired of ulnar nerve distal volar little finger s2PD to 15 mm.All the cases could achieve making a fist with thumb and a thumb could be oppoiste to other 4 fingers,and the ankle joint movement was normal.Conclusion Transplantion of free fibula composite tissue flap to the repair of forearm bone and soft tissue serious defect is an ideal surgical operation method.