1.Biological effects of the autoantibody against ?_3-adrenoceptor from the sera of rats with heart failure
Meixia LI ; Haifeng ZHANG ; Yanqing ZHANG ; Zhongmei HE ; Xiaojun LIU ; Rongrui ZHAO ; Huirong LIU
Chinese Journal of Pathophysiology 2000;0(12):-
AIM: To investigate the relation between myocardial remodeling and the genesis of serum anti-?_3-adrenoceptor autoantibody,an animal model of heart failure(HF) was established and the biological effects of the autoantibody were observed.METHODS:(1) Healthy male Wistar rats were subjected to HF by constricting the abdominal aorta.(2) The anti-?_3-adrenoceptor autoantibody in the sera of HF rats was detected by ELISA with the synthetic peptide of the second extracellular loop of the ?_3-adrenoceptor used as the antigen.(3) IgG in the positive sera from HF rats was prepared using a MabTrap Kit(Amersham).(4) The effects of the autoantibody on the contractile response of adult(isolated) cardiomyocytes and on the beating rate of cultured neonatal rat cardiomyocytes were observed.RESULTS:(1) The positive rate of anti-?_3-adrenoceptor autoantibody of rats increased from 21.05% of pretreatment to 78.95% after heart failure(P
2.Psychological Factors Analysis of Postpartum Body Pain
Menghan LV ; Weidong WANG ; Fang WANG ; Yingna LIN ; Rongrui ZHANG ; Yang ZHAO
International Journal of Traditional Chinese Medicine 2009;31(1):55-56
"Postpartum Body pain"refers to such symptoms as body pain,numbness,heaviness,arthralgia and even paralysis in a woman during the postpartum period.Besides the above symptoms,the patient may also have other symptoms like sleep disorder,emotional hindrance,somatization symptoms such as fatigue,sleepy,and chest distress,etc.This disease may be considered as somatization symptoms due to postpartum depression,but actually it is a psychogenic disorder.Clinical observation showed there were no clinical changes of objective signs such as red,swelling and fever;Laboratory examinations showed there was no ahnormal manifestation.This article primarily discussed"postpagtum body pain"from medicopsychological angle,hoping to help people get a right recognition of this disease.
3.Design of an anatomic plate of ulna coronoid process by 3D printing and computer software
Yanxi YANG ; Shijie ZHANG ; Yi LIU ; Yongcheng CHEN ; Bei LIU ; Rongrui YANG ; Maogeng YANG ; Di WU
Chinese Journal of Orthopaedic Trauma 2023;25(2):154-160
Objective:To design an anatomical plate of ulna coronoid process using 3D printing and computer model design software based on a collection of CT scanning data of the ulna coronoid process.Methods:The CT scans of the elbow joint with no obvious anatomic variation, no fracture, or no history of elbow operation were collected which had been taken at Trauma Center, The First Affiliated Hospital of Kunming Medical University from September 2017 to January 2022. There were 52 males and 50 females. RadiAnt DICOM Viewer and Mimics Medical 21.0 were used to visualize the CT data of the elbow joint of 102 volunteers. The software was used to measure the angle between the tip of the ulna coronoid process and the tuberosity of the ulna, the width at 1/2 height of the ulna coronoid process, the distance between the tip of the ulna coronoid process and the horizontal plane of the ulna tuberosity, and the safety angle for screw placement. After the values were measured, Siemens Ungraphics NX12.0 software was used to design the anatomical plate and the screw guide device of the ulna coronoid process. After the plate model was designed, a 1:1 actual plate model of the ulna coronoid process was produced by 3D printing. The actual plate model was placed onto an adult model of the ulna coronoid process and an adult cadaveric specimen of the ulna coronoid process to verify its matching degree. An in vitro operation was simulated using the plate model to verify its operability. Results:There were no significant differences between the left and right sides in the angle between the tip of the ulna coronoid process and the tuberosity of the ulna, the width at 1/2 height of the ulna coronoid process, the distance between the tip of the ulna coronoid process and the horizontal plane of the ulna tuberosity, or the safety angle for screw placement in either males or females ( P>0.05). There were no significant differences between males and females in the angle between the tip of the ulna coronoid process and the tuberosity of the ulna or in the safety angle for screw placement ( P>0.05). There were statistically significant differences between males and females in the width of 1/2 height of the ulna coronoid process and the distance between the tip of the ulna coronoid process and the horizontal plane of the ulna tuberosity ( P<0.05). However, the experiments on computer simulative adaptation and plate model simulative adaptation found that the anatomical plates of the ulna coronoid process designed on various parameters of males and females were exchangeable, leading to similarly good marching degrees and safe angles for screw placement. Conclusions:The anatomical plate of the ulna coronoid process designed in this study demonstrates a good fit and a safe angle for screw placement, basically achieving the goal expected to provide a basis for fabrication of a titanium alloy plate. In design of an anatomical plate of ulna coronoid process, it is not necessary to differentiate males from females or to differentiate the left side from the right one, because only a general plate can be used for both males and females and for both the left and the right sides.