1.Suspicious on the Rationality of the Translocation of the Pricing of Prescriptions
China Pharmacy 1991;0(01):-
OBJECTIVE: To facilitate hospital service reform as well as the implementation of Prescription Management Method.METHODS: The advantages and disadvantages of pricing of prescriptions by financial staff versus dispensing staff were compared.RESULTS & CONCLUSIONS: The financial staff lay stress on economical income but the dispensing staff on rationality of prescriptions,and the latter plays an indispensible in preventing medical risk and ensuring patients' medication safety.It is advisable to establish network for the contents of drug prices and financial fee-collecting and to facilitate a cooperative office system of financial pricing staff and pharmacists.
2.Simultaneous Determination of Eight Compounds in Shegan Mixtures by UHPLC-MS/MS
Zhiyan LIN ; Rongfu YANG ; Yuenian TANG
China Pharmacist 2015;(4):574-577,578
Objective:To establish an UHPLC-MS/MS method to determine the contents of baicalin,scutellarin,wogonin,caffeic acid,ephedrine,belamcandin,irisflorentin and baicalein in Shegan mixtures. Methods:The chromatographic separation was performed on a ZORBAX SB-C18 column(2. 1 mm × 50 mm,1. 8 μm)with the mobile phase consisting of acetonitrile and water(0. 1% formic acid),the flow rate was 0.3 ml·min-1,and the column temperature was 35℃. Electrospray ionization source(ESI)was used with multiple reaction monitoring( MRM)combined with positive and negative scanning switch. üegative ion mode detection was used for caf-feic acid,belamcandin and scutellarin ,while positive ion mode detection was used for baicalin,wogonin,irisflorentin,baicalein and e-phedrine. Results:The quantification limit of baicalin,scutellarin,wogonin,caffeic acid,ephedrine,belamcandin,irisflorentin and ba-icalein was 1. 44 × 10-4 ,4. 20 × 10-3 ,2. 95 × 10-4 ,7. 80,4. 90 × 10-3 ,4. 6 × 10-2 ,3. 18 × 10-4 ng·ml-1 and 4. 85 ng·ml-1 . The detection limit was 4.32 ×10-5,1.3 ×10-3,8.84 ×10-5,0.77,2.90 ×10-4,3.33 ×10-4,9.5 ×10-5 ng·ml-1 and 1.46 ng· ml-1 ,respectively. The correlation coefficients( R2 )were all higher than 0. 992 3 within the linear ranges. Both intra- and inter-day RSD were less than 5%. The average recoveries of the eight components were within the range of 80%-120%. Conclusion:The method is simple,rapid,sensitive and accurate. It can be used to determine the contents of baicalin,scutellarin,wogonin,caffeic acid,ephed-rine,belamcandin,irisflorentin and baicalein in Shegan mixtures for the quality control.