OBJECTIVE:To determine the dissolubility of paracetamol in Ganmaoqing tablets produced by different manufactories and to evaluate the internal qualities METHODS:The content of paracetamol in Ganmaoqing tablets was determined by HPLC with Nova-Pak C18 or Sphereclone ODS(2) column as fixed phase and methanol-water(1∶3) as mobile phase Paracetamol was detected at 249 nm with UV detetor The flow rate was 0 5ml/min Rotating basket method was used in dissolution test RESULTS:The method could determine the content of paracetamol in Ganmaoqing tablets satisfactorily The dissolution rates of eight samples were quite different CONCLUSION:The method is simple,rapid and reliable It is very necessary to establish the dissolubility standard for Ganmaoqing tablets