1.Analysis of radiation dose to patients during coronary angiography and intracoronary stenting using radial and femoral artery access
Yang HUANG ; Yongming ZENG ; Renqiang YU ; Li TAO
Chongqing Medicine 2014;(1):39-41
Objective To evaluate the radiation dose to patients using radial and femoral artery access in coronary angiography (CAG) and intracoronary stenting (IS) ,provide basis for clinical intervention path .Methods The data of 190 samples (43 by femo-ral and 147 by radial) underwent CAG and 54 samples (17 by femoral and 37 by radial) underwent CAG+IS were analyzed retro-spectively .All samples were divided into two groups (radial group and femoral group) by different approach ,and radiation dose in different approach were analyzed .Results There was no significant difference of Dose Area Product (DAP) and Cumulative Dose (CD) using femoral and radial access in CAG (P>0 .05) .Separating two samples which CD were much higher than others ,the mean DAP was 23 .93 Gy · cm2 and the mean CD was 358 .85 mGy using radial vs .27 .06 Gy · cm2 and 369 .57 mGy using femoral , not distinctive either(P=0 .734 ,P=0 .834) .In CAG+IS ,the mean DAP was 82 .64 Gy · cm2 using radial and it was 78 .11 Gy · cm2 using femoral ,and the mean CD was 1 286 .41 mGy using radial and it was 1 267 .76 mGy using femoral .There were no signifi-cant difference in both DAP and CD (P=0 .705 ,P= 0 .919) .Conclusion The radiation dose of DAP and CD were not different when using radial access and using femoral access in CAG and CAG +IS .
2.Impact of image quality with scan parameters and reconstruction algorithms in head dual-energy computed tomography angiography
Gang PENG ; Yongming ZENG ; Renqiang YU ; Jie WANG
Chongqing Medicine 2016;45(16):2236-2238,2241
Objective To study the difference of image quality which based on different reconstruction in head dual‐energy computed tomography angiography (DECTA) scanning ,and evaluate the radiation dose which using different tube voltage in DEC‐TA .Methods An anthropomorphic head phantom with simulated arteries was used for DECTA scanning by different scan parame‐ters (tube voltage 80/140 kV and tube voltage 100/140 kV) ,the data was reconstructed with filtered back projection (FBP) and Si‐nogram Affirmed Iterative Reconstruction (SAFIRE) .The CT values with SD were measured and calculate to SNR and CNR ,the dose length product (DLP) was recorded and invert to effective dose .The image quality and radiation dose were evaluated in differ‐ent imaging condition .Results The image noise of SAFIRE reconstruction was lower than FBP reconstruction in same san parame‐ters .The increase of tube current‐time product from 100 mAs to 300 mAs ,it shows the characteristics of linear tendency .When it was on 260 mAs ,the image quality become stable .The difference between the two groups(80/140 kV ,100/140 kV)of SD of CT value by SAFIRE was significant (P< 0 .05) ,the difference of SNR and CNR between the two groups was not significant (P>0 .05) .The effective doses of group A (80/140 kV) was significantly lower than group B(100/140 kV) .Conclusion Using tube voltage of 80/140 kV combine with SAFIRE algorithm in head DECTA can ensure the image quality ,which can significantly reduce radiation dose .
3.Effectiveness of iterative metal artifact reduction for reduction of metal artifact in chest CT scanning
Bin YU ; Furong LYU ; Li ZHANG ; Jingkun SUN ; Gang PENG ; Jie WANG ; Renqiang YU
Chinese Journal of Medical Imaging Technology 2017;33(4):590-593
Objective To assess the effectiveness of iterative metal artifact reduction (IMAR) on metal artifacts reduction in thorax scan.Methods Thoracic phantom with two pedicle screws implanted in both sides of the T5 vertebrae was used,with the scan parameters of 130 kV and CARE Dose 4D,the phantom was scanned with and without the screws respectively.Images without screws were reconstructed with FBP.Images with screws were reconstructed with FBP and IMAR respectively.Three ROIs were selected on tissues including aorta,pulmonary and paravertebral soft tissue on image slice adjacent to the screws.The CT value and standard deviations (noise) of ROIs were measured,and the deviation of CT value (△HU) was calculated as the difference between CT values in images with and without screws.Twenty-six cases who received chest CT examination and with pedicle screw implant in scanning range were collected.The scanning parameters and image reconstruction methods were the same as phantom scan.The CT value (HU) of metal artifacts adjacent to vertebrae and dorsal soft tissue was measured,and the image quality of reconstructed image by two skilled radiologists independently was evaluated.Results In the phantom after implanted screws,the noise were significantly reduced by IMAR compared to FBP in all the three ROIs of aorta,pulmonary and paravertebral soft tissue (P<0.05),and the △HU was significantly smaller in IMAR compared to that with FBP (P<0.01).In 26 patients,there were significant differences in CT value of vertebral bone tissue and dorsal soft tissue between FBP and IMAR (P<0.05),and the subjective evaluation scores of the two image reconstruction methods showed a statistically significant difference (P<0.05).Conclusion IMAR can significantly reduce streak artifacts of metal implant and adjuste the CT values of artifact affected tissues to make it more close to the true value without metal implant.
4.An experimental study of comparing digital tomosynthesis and multi-slice CT scanning for the detection of pulmonary nodules using the anthropomorphic chest phantom
Feng ZHAO ; Yongming ZENG ; Shengkun PENG ; Gang PENG ; Renqiang YU ; Huan TAN ; Wenjing CAI
Chinese Journal of Radiology 2012;46(4):363-366
ObjectiveTo compare detection rate of pulmonary nodules and the radiation doses of digital tomosynthesis (DTS) and MSCT chest scanning by using the anthropomorphic chest phantom which containsthermoluminescent dosimeters( TLD ) and simulated pulmonary nodules.Methods The radiation doses of DTS and MSCT scanning were measured by using the anthropomorphic chest phantom which contains 45 TLD and simulated pulmonary nodules.The radiation doses of najor organs were converted into effective dose ( ED ). Three radiologists of different clinical experiences independently reviewed and recorded the density,diameter and position of pulmonary nodules.The sensitivity of nodule detection by DTS and MSCT were compared by Fisher exact test and Chi-square test. The paired t test was conducted to analyze the dose levels of DTS and MSCT.ResultsThe sensitivity of detection nodule by DTS and MSCT were 66.7% (30/45) and 91.1% (41/45) respectively.Statistically significant difference between the two examinations existed ( x2 =8.073,P < 0.05).The sensitivity of detection - 650 HU ground glass opacity pulmonary nodule by MSCT and DTS were 93.3% (14/15) and 73.3% (11/15) respectively.There was no significant difference between DTS and MSCT ( P > 0.05 ).The sensitivity of detection - 800 HU ground glass opacity nodule and ground glass opacity nodule (d < 8 mm) by DTS were 33.3% (5/15) and 16.7% (2/12) respectively,which were lower than those by CT[80.0% (12/15) and 66.7% (8/12)].The radiation doses of DTS for various organs in the chest were lower than those of CT. Statistical significant difference between DTS and MSCT existed ( lung t =19.69,thoracic vertebral t =30.01,heart t =16.33,liver t =5.06,breast t =9.43,thyroid gland t =8.05 ;P < 0.05).The effective doses of the DTS and MSCT were 0.65 and 7.71 mSv respectively.ConclusionsThere is no difference between the DTS and MSCT in the detection rate of -650 HU ground glass opacity nodule.For detecting the ground glass opacity nodule ( - 800 HU) and ground glass opacity nodule (d < 8 mm),MSCT is superior to DTS. However,the radiation dosage of DTS is 8.41% of the MSCT scanning.
5.The measurement of organic radiation dose of multi-slice CT scanning by using the Chinese anthropomorphic chest phantom
Gang PENG ; Yongming ZENG ; Tianyou LUO ; Feng ZHAO ; Zhiwei ZHANG ; Renqiang YU ; Shengkun PENG
Chinese Journal of Radiology 2011;45(6):584-588
Objective Using the Chinese anthropomorphic chest phantom to measure the absorbed dose of various tissues and organs under different noise index, and to assess the radiation dose of MSCT chest scanning with the effective dose(ED). Methods The equivalence of the Chinese anthropomorphic chest phantom(CDP-1C) and the adult chest on CT sectional anatomy and X-ray attenuation was demonstrated. The absorbed doses of various tissues and organs under different noise index were measured by laying thermoluminescent dosimeters(TLD) inside the phantom, and the corresponding dose-length products(DLP) were recorded. Both of them were later converted into ED and comparison was conducted to analyze the dose levels of chest CT scanning with automatic tube current modulation (ATCM) under different noise index. Student t-test was applied using SPSS 12.0 statistical software. Results The Phantom was similar to the human body on CT sectional anatomy. The average CT value of phantom are -788.04 HU in lung,45.64 HU in heart,65.84 HU in liver,254.32 HU in spine and the deviations are 0.10%,3.04%, 4.49% and 4.36% respectively compared to humans. The difference of average CT value of liver was statistically significant(t=-8.705,P<0.05),while the differences of average CT values of lung, heart and spine were not significant(t value were -0.752,-1.219,-1.138,respectively and P>0.05).As the noise index increased from 8.5 to 22.5, the DLP decreased from 393.57 mGy·cm to 78.75 mGy·cm and the organs dose declined. For example, the average absorbed dose decreased from 22.38 mGy to 3.66 mGy in lung. Compared to ED calculating by absorbed dose, the ED calculating by DLP was lower. The ED values of the two methods were 6.69 mSv and 8.77 mSv when the noise index was set at 8.5. Conclusions Application of the Chinese anthropomorphic chest phantom to carry out CT dose assessment is more accurate. The noise index should be set more than 8.5 during the chest CT scanning based on ATCM technique.
6.Evaluation on Ability to Detect the Intracranial Hematoma with Different Density Using C-Arm Cone-beam Computed Tomography Based on Animal Model.
Mi ZHOU ; Yongming ZENG ; Renqiang YU ; Yang ZHOU ; Rui XU ; Jingkun SUN ; Zhimei GAO
Journal of Biomedical Engineering 2016;33(1):120-125
This study aims to evaluate the ability of C-arm cone-beam CT to detect intracranial hematomas in canine models. Twenty one healthy canines were divided into seven groups and each group had three animals. Autologous blood and contrast agent (3 mL) were slowly injected into the left/right frontal lobes of each animal. Canines in the first group, the control group, were only injected with autologous blood without contrast agent. Each animal in all the 7 groups was scanned with C-arm cone-beam CT and multislice computed tomography (MSCT) after 5 minutes. The attenuation values and their standard deviations of the hematoma and uniformed brain tissues were measured to calculate the image noise, signal to noise ratio (SNR) and contrast to noise ratio (CNR). A scale with scores 1-3 was used to rate the quality of the reconstructed image of different hematoma as a subjective evaluation, and all the experimental data were processed with statistical treatment. The results revealed that when the density of hematoma was less than 65 HU, hematomata were not very clear on C-arm CT images, and when the density of hematoma was more than 65 HU, hematomata showed clearly on both C-arm CT and MSCT images and the scores of them were close. The coherence between the two physicians was very reliable. The same results were obtained with C-arm cone-beam CT and MSCT grades in measuring SD value, SNR, and CNR. The reasonable choice of density detection range of intracranial hematoma with C-arm cone-beam CT could be effectively applied to monitoring the intracranial hemorrhage during interventional diagnosis and treatment.
Animals
;
Cone-Beam Computed Tomography
;
Disease Models, Animal
;
Dogs
;
Hematoma
;
diagnosis
;
Image Processing, Computer-Assisted
;
Intracranial Hemorrhages
;
diagnosis
;
Multidetector Computed Tomography
;
Signal-To-Noise Ratio
7.Vitamin D levels in preterm infants
Renqiang YU ; Xiangpeng LIAO ; Xueting LIU ; Min JIANG ; Shanyu JIANG ; Qin ZHOU
Journal of Clinical Pediatrics 2017;35(4):259-263
Objective To analyze serum 25(OH)D level and the influence factors in preterm infants. Methods The data of serum 25(OH)D level in preterm infants born from July 2012 to June 2014 were retrospectively analyzed along with gestational age, gender, parity, delivery mode, birth season, birth weight, age of the mother and pregnancy complications. Results Totally 325 cases were included and their average gestational age was 33.41±2.29 week, the ratio of male to female was 1.32?1 and average serum 25(OH)D level was 37.34±16.17 nmol/L. The incidence of vitamin D deficiency and insufficiency in preterm infants was 37.8% and 41.8% respectively. Serum 25 (OH) D levels in preterm infants born in summer and autumn were higher than those born in winter and spring, and there was statistical difference (P<0.05). Logistic regression analysis showed that birth season and the mother's age may be the risk factors that influence serum 25 (OH) D levels in preterm infants. Conclusion The incidence of vitamin D deficiency and insufficiency in preterm infants is high, and the factors affecting the level of vitamin D need to be further studied.
8.The clinical application of the recovery time after ST segment depression for the diagnosis of coronary heart disease
Jingqi YANG ; Qinghua WU ; Wen SHEN ; Yu JIANG ; Jing CHEN ; Renqiang YANG
The Journal of Practical Medicine 2015;(18):2975-2977
Objective To investigate the clinical significance of the ST segment changing in treadmill exercise test positive for the diagnosis of coronary heart disease. Methods 133 patients (hospitalized from January 2014 to January 2015) with the ST segment depression≥0.1 mm in treadmill exercise test were retrospectively analyzed. Patients were divided into the observation group and the control group according to the coronary angiography (the dividing line is artery stenosis is more than 50% or not ). ST-segment depression margin and recovery time of the two groups were compared. ST-segment depression margin and recovery time of patients with different vascular lesion number were also analyzed. Results In 133 cases, 79 cases of coronary angiography were positive(59.4%). Positive rate of ST segment recovery time(> 90 s) was 76.9% in. The maximal ST-segment depression margin and recovery time in the observation group were more than the control group, the difference was statistically significant (P<0.05). Compared with the maximal ST segment depression margin in single-vessel stenosis group , the difference in the double-vessel and multi-vessel stenosis group was not statistically significant(P > 0.05). But in terms of ST-segment recovery time, the double-vessel and multivessel stenosis group were higher than the single-vessel stenosis group , and the difference was statistically significant (P< 0.05). Conclusion Clinically, patients with TET positive combined the ST segment depression and ST-segment recovery time are important hints for the diagnosis of coronary artery disease , and is worthy of promotion.
9.Application of Monte Carlo software in estimating patients' radiation dose during CCTA and confirmation by anthropomorphic phantom study
Xiao LIU ; Yongming ZENG ; Shengkun PENG ; Renqiang YU ; Jie WANG ; Jingkun SUN
Chinese Journal of Radiological Medicine and Protection 2014;34(2):152-154
Objective To evaluate the accuracy and efficiency of the Monte Carlo software in measuring the radiation dose to the patients who received the CCTA (Coronary Computed Tomography Angiography) examination.Methods A anthropomorphic chest phantom underwent CCTA using three scan parameters (tube voltage 80 kV,100 kV and 120 kV).Computer Software ImpactDose 2.0 was used to compute the chest organ dose on the basis of the three groups tube voltage CT scan characteristic,and the stimulation results of ImpactDose 2.0 software was verified by use of anthropomorphic phantom thermoluminescence dosimeter experiment method.Results For all the measured organs except for lung,the absorbed organ dose and effective dose of three groups of tube voltages of CCTA measured by the InpactDose 2.0 was lower than those as measured by anthropomorphic phantom study.The relative error of both methods was within ± 50%.Conclusions Monte Carlo software can be used to estimate the levels of radiation dose during CCTA examination with a tolerable error within the acceptable range.
10.Correlation between the tube current and image noise in low-dose chest CT scean
Feng ZHAO ; Yongming ZENG ; Gang PENG ; Huizhi CAO ; Jingmin LIAO ; Renqiang YU ; Shengkun PENG ; Huan TAN
Chinese Journal of Radiological Medicine and Protection 2012;32(1):100-103
Objective To analyze the distribution of image noise in low-dose chest CT scan and optimize the relative scanning parameters.Methods The CT images of the Chinese anthropomorphic chest phantom( CDP-1 C) were simulated into six groups of low-dose images with different noise indexs by using an image noise addition tool.The difference between the preset noise index and analog noise value was compared.The CT images of 20 volunteers were also simulated into nine groups of low dose scans with the tube currents of 10,30,50,80,100,120,150,180 and 240 mA.The noise values of images were recorded and analyzed.Results There was no statistical difference between the analog noise value and the noise index.The image noise of low-dose chest scan was increased with the decrease of tube current.The noise was increased quickly when the current was decreased from 50 to 30 mA ( F =24.09 - 40.79,P < 0.05),but the noise increased slowly when the current decreased from 240 to 80 mA.There was no statistical difference between the noise of 80 mA group and that of 120 mA(P > 0.05).Conclusions The noise addition tool can be used to evaluate the image noise of low-dose chest CT scan.Adoption of 80 mA in chest CT scan would result in low radiation dose without adding image noise.