1.Diagnostic value of conventional ultrasound and contrast enhanced ultrasound in predicting extrathyroidal extension of papillary thyroid cancer
Ke DING ; Qiuli CUI ; Kun YAN ; Wenying LIU ; Tianxiao WANG
Chinese Journal of Ultrasonography 2017;26(3):243-248
Objective To explore the diagnostic value of conventional ultrasound(US) and contrast enhanced ultrasound(CEUS) in predicting extrathyroidal extension of papillary thyroid cancer(PTC).Methods Eighty-five PTCs in 75 patients were selected for thyroid surgery underwent ultrasound and contrast-enhanced ultrasound.The degrees of contact between PTCs and capsule were observed by US and CEUS respectively(0,0-25%,25%-50%,≥50%),and the diagnostic efficiency in different degree of contact (>0 %,≥25 %,≥50%) as preoperative diagnostic criteria were analyzed.The diagnostic efficiency between US and CEUS in predicting extrathyroidal extension of PTC were compared.Results Of the 85 PTCs,extrathyroidal extension was presented in 57 (67.06%) based on pathologic results.When the degree of contact (> 0 %,< 25 %,25 %-50 %,≥ 50 %) was gradually increased,the incidence of extrathyroidal extension of the thyroid cancer was also gradually risen (P <0.001).Comparing the sensitivity,accuracy,odds ratio,and Az value of three groups(>0%,≥25%,≥50%),it showed that the general diagnostic efficiency between two groups(>0%,≥25%) was similar by US and CEUS.However,the sensitivity and accuracy of >0% contact with the adjacent capsule were markedly higher than those of the other two groups(P <0.001).Selecting >0% contact with the adjacent capsule as preoperative criteria,the Az value of CEUS was markedly higher than that of US (Z =2.208,P =0.027).Conclusions The preoperative imaging feature of more than 0% contact with the adjacent capsule is more sensitive and accurate degree in predicting extrathyroidal extension of PTC.Compared with US,CEUS may serve as a better useful tool to predict extrathyroidal extension of PTC.
2.Multi-channel Synchronization Analysis of Mild Cognitive Impairment in Type 2 Diabetes Patients.
Dong CUI ; Jing LIU ; Zhijie BIAN ; Jinhuan WANG ; Qiuli LI ; Xiaoli LI ; Lei WANG
Journal of Biomedical Engineering 2015;32(2):279-283
The cognitive impairment of type 2 diabetes patients caused by long-term metabolic disorders has been the current focus of attention. In order to find the related electroencephalogram (EEG) characteristics to the mild cognitive impairment (MCI) of diabetes patients, this study analyses the EEG synchronization with the method of multichannel synchronization analysis--S estimator based on phase synchronization. The results showed that the S estimator values in each frequency band of diabetes patients with MCI were almost lower than that of control group. Especially, the S estimator values decreased significantly in the delta and alpha band, which indicated the EEG synchronization decrease. The MoCA scores and S value had a significant positive correlation in alpha band.
Cognitive Dysfunction
;
diagnosis
;
Cortical Synchronization
;
Diabetes Mellitus, Type 2
;
Electroencephalography
;
Humans
3.Correlation study of ultrasonic strain elastography quantitative analysis with benign or malignant thyroid lesions
Wenying LIU ; Wei YANG ; Qiuli CUI ; Yuntao SONG ; Minhua CHEN ; Kun YAN
Chinese Journal of Ultrasonography 2014;23(10):879-882
Objective To explore the feasibility for the tissue dispersion quantitative analysis software of ultrasonic strain elastography in diagnosing benign or malignant of thyroid lesions.Methods Eighty-two patients with 98 lesions were examined by ultrasonic strain elastography.There were 11 parameters of elastography imaging obtained by the tissue dispersion quantitative analysis software,including average relative strain value(MEAN),standard deviation of relative strain value(SD),area ratio of low-strain region (AREA%),complexity(COMP),kurtosis(KURT),skewness (SKEW),contrast (CONT),entropy(ENT),inverse different moment (IDM),angular second moment (ASM),correlation (CORR).The receiver operating characteristic (ROC) curve was constructed if there were statistically significant differences between benign and malignant lesions,and the areas under the ROC curve were got.Results All parameters except CORR had statistically significant between the groups of benign and malignant thyroid lesions (P <0.05).The AREA% and IDM were the best valuable parameters,the areas under the curve(AUC) of which were 0.965 and 0.908,respectively.Their cut-off point were 81.96% and 0.42,the sensitivity and specificitywere 98.4% and 89.2%,91.8% and 86.5%,respectively.Conclusions The tissue dispersion quantitative analysis software is helpful in the evaluation of benign ormalignant of thyroid lesions,parameters of AREA% and IDM has the highest relationship with pathology and good diagnostic value.
4.Contrast enhanced ultrasonogrphy patterns in papillary thyroid carcinoma and correlation between degree of enhancement and tumor invasiveness
Qiuli CUI ; Wenying LIU ; Guanghan LI ; Kun YAN ; Wei YANG ; Minhua CHEN
Chinese Journal of Ultrasonography 2015;(7):580-583
Objective To study the enhanced patterns of papillary thyroid carcinoma (PTC)on contrast-enhanced ultrasound(CEUS),and explore the relationship between the degree of enhancement and extracapsular invasionand cervical lymph node metastasis of the tumor.Methods Seventy-three PTCs in 61 patients selected for thyroid surgery underwent conventional ultrasound andcontrast-enhanced ultrasound. The enhanced patterns were analyzed.The differences between different degree enhancement and extracapsular invasion and cervical lymph node metastasis of PTCs were compared.Results Seventy-three PTCs enhanced patterns showed that 52(71 .2%)nodules with hypoenhancement,13(1 7.8%)nodules with isoenhancement,8 (1 1 .0%)nodules with hyperenhancement.Twenty-three (44.2%,23/52 )nodules with extracapsular invasion in hypoenhancing patterns,and 1 5 (71 .4%,1 5/21 ) nodules with extracapsular invasion in isoenhancing or hyperenhancing patterns.There were significant differences between them(P <0.05).Twenty-five (48.1 %,25/52 ) nodules with cervical lymph node metastasis in hypoenhancing patterns,and 13 (61 .9%,13/21 ) nodules with cervical lymph node metastasis in isoenhancing or hyperenhancing patterns,there was no significant difference between them(P >0.05 ).Conclusions The degree of enhancement are correlate to invasiveness in PTCs,PTCs with isoenhancement or hyperenhancement patterns were more often with extracapsular invasion.
5.Transvaginal Contrast-enhanced Sonography in the Differentiation of Benign from Malignant Adnexal Masses
Junyan WANG ; Qiuli CUI ; Aijun LIU ; Xuewen GAO ; Longxia WANG ; Li SU ; Yuanqing YAO ; Enfeng ZHAO ; Xiuli LI ; Weiping LI ; Hong XU ; Zhixian YUAN ; Qian LIN
Chinese Journal of Medical Imaging 2009;(6):412-415
Purpose:The study was designed to investigate the feasibility of contrast-enhanced ultrasound in the differentiation of benign and malignant adnexal masses.Materials and Methods:Sixty-nine consecutive patients with adnexal masses received trans vaginal contrast-enhanced ultrasound.The image and perfusion features were assessed.Results:All of 26 malignant tumors showed detectable contrast enhancement,including 24 cases with a quick,heterogeneous or branching pattern.Among 39 benign lesions,24 were cystic with circle or half-circle enhancement,including 5 cases with intra-cystic septum or papillae slightly enhanced.The other 15 cases were solid,8 of them had slightly dotted enhancement.There are significant difference in enhancement patterns between benign and malignant masses ( P < 0.0001).The 4 cases of borderline tumors showed progressive,heterogeneous enhancement.Conclusion:Contrast-enhanced ultrasound is of value in the differentiation of benign and malignant adnexal masses.
6.Preliminary study on the relationship between the contrast-enhanced ultrasonography of liver metastasis and the differentiation degree of neuroendocrine tumors
Shanshan YIN ; Binbin JIANG ; Qiuli CUI ; Zhihui FAN ; Wei WU ; Ying DAI ; Wei YANG ; Kun YAN
Chinese Journal of Ultrasonography 2019;28(2):108-113
Objective To retrospectively analyze contrast-enhanced ultrasound ( CEUS ) manifestations of neuroendocrine tumors ( NETs) liver metastases ,and explore the relationship between CEUS parameters and differentiation of NETs . Methods From January 2014 to June 2018 ,36 patients who had been performed CEUS due to liver metastasis of NETs with pathological diagnosis and immunohistochemical staining results were enrolled in this study . The CEUS findings of NETs liver metastases were summarized . According to the Ki-67 index ,CgA results ,and the stage G ,the patients were divided into Ki-67>20% group and Ki-67≤20% group ,CgA negative group and CgA positive group ,and group G1+G2 and group G3 ,respectively . The CEUS parameters of NETs liver metastases between the above groups were compared . Results In 36 lesions ,during the arterial phase of CEUS ,66 .7% (24/36) showed hyperenhancement ,16 .7% (6/36) isoenhancement ,13 .9% (5/36) rim-like enhancement ,and 5 .6% ( 2/36 ) hypoenhancement ; During the portal phase , 13 .9% ( 5/36 ) showed hyper or iso enhancement ,86 .1% (31/36) showed hypoenhancement . The average washout time was ( 67 .5 ± 56 .1)s ,of which 5 (13 .9% ) lesions were washed out after 120 s . The mean starting washout time was statistically different between the CgA negative group and the positive group[(91.6±81.5)svs(60.1±38.7)s,P =0 .001] . There was no statistically significant difference in all observations between the group of Ki-67≤20% and >20% ,group G1+G2 and group G3( P >0 .05) . Conclusions CEUS of NETs liver metastasis has certain characteristics ,among which hyperenhancement is its main enhancement mode ,and some lesions have a longer wash out time . The relationship with the degree of differentiation needs further investigation .
7.Initial research for the diagnostic value of contrast-enhanced ultrasound parametric imaging in predicting extracapsular invasion and cervical lymph node metastasis of papillary thyroid cancer
Ke DING ; Kun YAN ; Qiuli CUI ; Wei YANG ; Wei WU ; Shanshan YIN ; Wenying LIU
Chinese Journal of Ultrasonography 2018;27(12):1054-1057
Objective To study the enhanced performance of contrast-enhanced ultrasouond( CEUS) parametric imaging , and to explore the diagnostic value of CEUS parametric imaging in predicting extracapsular invasion and cervical lymph node metastasis of papillary thyroid cancer( PTC) . Methods One hundred and fifty-eight PTCs in 136 patients pathologically proven papillary thyroid carcinoma between January 2016 and January 2017 were enrolled in this study . According to the pathological results of extracapsular invasion and cervical lymph node metastasis respectively ,the PTCs were grouped into the negative group and the positive group . The parametric imaging features of the two groups were summarized to explore the risk factors of extracapsular invasion and cervical lymph node metastasis of PTCs respectively . Results The parametric imaging suggested that centripetal enhancement had a significant effect on extracapsular invasion ( P =0 .001) . While there was no difference in the perfusion start time of extracapsular invasion between the negative and positive group ( P > 0 .05 ) . Besides , there was no statistical significance in the perfusion start time and perfusion pattern of cervical lymph node metastasis between the negative and positive group (all P >0 .05) .Conclusions The parametric imaging features help predicting extracapsular invasion in PTCs . And the ones with centripetal enhancement patterns are more often with extracapsular invasion .