1.Performance verification of VITROS 5600 automatic biochemical analyzer
Miaochen YU ; Qinmin SUN ; Fengquan JIANG
International Journal of Laboratory Medicine 2017;38(1):56-60
Objective To verify the performance of VITROS 5600 automatic biochemical analyzer.Methods According to laboratory accreditation criteria and performance verification documents of American CLIA'88,the precision,accuracy,liner range,clinical reportable range and biological reference interval were verified for the test of 17 conventional biochemical indicators performed on VITROS 5600 automatic biochemical analyzer.Results The precision、accuracy、liner range、clinical reportable range and biological reference interval of VITROS 5600 automatic biochemical analyzer were all acceptable.Conclusion VITROS 5600 automatic biochemical analyzer could fully meet the requirements in clinical application.
2.Diagnostic performance of HCV antibody and RNA Determination
Yanan GU ; Qinmin SUN ; Bingjie YAO ; Shijun LI ; Zhen WANG
International Journal of Laboratory Medicine 2014;(18):2448-2450
Objective To explore changes of anti-HCV antibody and HCV-RNA in patients with HCV infection and its clinical significance in diagnosis and treatment of hepatitis C .Methods Serum samples from patients with HCV infection were collected . HCV antibodies were analyzed with a chemiluminescence micro-particle immunoassay method ,while a PCR-fluorescent probe meth-od was used to detect HCV-RNA .Concentrations of ALT and AST were also determined .Based on the concentrations of ALT , AST and HCV-RNA ,samples were divided into two groups respectively and the changes of different indicators were analyzed and compared .Meanwhile samples from 37 HCV-infected patients were collected continuously .Different indicators after treatment were compared with those before treatment .Results HCV-Ab and logarithm values of RNA load in the group with abnormal concentra-tions of ALT and AST were significantly higher than those in the normal group (P<0 .05) .HCV-Ab ,ALT and AST concentrations in HCV-RNA positive group were significantly higher than those in HCV-RNA negtive group(P<0 .05) .The areas under receiver operating characteristic curve of HCV-Ab and logarithm values of RNA load were 0 .990 and 0 .838 respectively .Concentrations of ALT ,AST and logarithm values of RNA load after treatment were significantly lower than those before treatment (P<0 .05) while there was no significance between HCV-Ab level after treatment and that before treatment (P>0 .05) .Conclusion The diagnostic performance of HCV-Ab is better than that of logarithm values of RNA load .Determination of ALT ,AST and HCV-RNA is of clinical importance in monitoring the effect of hepatitis C treatment .