1.Relationship between the level of serum C-reactive protein and prognostic value in patients with congestive heart failure
Shenghong ZENG ; Qinghui ZHOU ; Danian NIE
Chinese Journal of Primary Medicine and Pharmacy 2008;15(10):1674-1675
Objective To determine whether the level of serum C-reactive protein(CLIP) had prognestie val-ue in patients with congestive heart failure(CHF). Methods Serum CRP was measured by enzyme-linked immuno-assay. Results CRP concentration was ( 8.66±4.38 ) mg/L in CHF patients and (1.12±0.87)mg/L in controls( P<0.01). In patients with LVEF ≤35% and > 35%, CRP was ( 11.92±4.55 ) mg/L and ( 5.88±1.92) mg/L( P<0.01 ). In patients with heart function class Ⅰ,Ⅱ,Ⅲ and Ⅳ, CRP was ( 3.92±0.79 ) mg/L, (5.03±1.55 ) mg/L,(8.94±2.97)mg/L, ( 12.21±4.43 ) mg/L, respectively. A negative correlation was observed between serum C RP concentration and LVEF in patients with CHF( r=-0.502,P<0.01 ). According to the concentration of CLIP,83 pa-tients with CRP≥10mg/L had mortality of 32.50% ,109 patients with CRP<10mg/L and ≥5mg/L had mortality of 10.48%,and 150 patients with CRP < 5mg/L had mortality of 2.76%. Conclusion This study shows that serum CRP is increased and has prognostic value in patients with CHF,that the level of CRP is parallel to the severity of CHF.
2.Study on the Optimization of Matrix Formula of Lanlian Ertong Qingre Cataplasm
Na LU ; Dengke XIONG ; Wan YANG ; Qinghui ZENG ; Zhijun HUANG
China Pharmacy 2015;26(31):4412-4415
OBJECTIVE:To optimize the matrix formula of Lanlian ertong qingre cataplasm. METHODS:Taking adhesion force,peel strength and sensory description as index,the ratio of matrix framework material(sodium polyacrylate-gan hydroxyl alu-minum-tartaric acid-glycerin) was optimized with orthogonal test. The single factor test was adopted to select adhesive and filler;the amount of penetrating agent azone was screened using the in vitro penetration amount of phillyrin. RESULTS:The best matrix ratio of Lanlian ertong qingre cataplasm was sodium polyacrylate-gan hydroxyl aluminum-tartaric acid-glycerin(4.0:0.8:0.4:15);PVP K-90 was used as adhesive,and bolus alba as filler;penetration enhancers azone accounted for 2.0%. Validation test showed, prepared cataplasm had good appearance,could stick on the 5th or the 6th ball;it's peel strength was 7.5 N;all RSDs of score were lower than 4%(n=3). CONCLUSIONS:The optimized matrix formula of Lanlian ertong qingre cataplasm is simple,stable and good in molding.
3.Struma ovarii:CT findings with corresponding pathological basis
Heng LIU ; Qinghui ZENG ; Pan LIU ; Yonghua BAI ; Bangguo LI ; Tijiang ZHANG
Journal of Practical Radiology 2015;(6):966-968
Objective To study the CT findings of struma ovarii(SO)and improve the understanding of SO imaging features. Methods CT images of 6 cases were retrospectively reviewed.CT plain scan was performed in 6 patients;CT enhancement scan was performed in 2 patients.Results All tumors were unilateral.On non-enhanced CT,the lesions presented as well-defined irregu-lar cystic-solid masses.The cystic portions presented as well-defined,multiple,various size,and there were entire cystic walls with smooth inner wall.Four tumors showed high attenuation lesions in the cyst portion of the mass on precontrast scans.The solid por-tions showed irregular tissue density,and were often distributed in the cysts.The tumors showed stippled calcification in solid por-tions and/or cystic wall in 4 cases.One tumor accompanied a great of ascites liquid.After contrast administration,the cystic por-tions showed no enhancement,and the cystic walls and the solid portions showed mild enhancement.Conclusion CT findings of SO have certain characteristics such as a cystic-solid and well-defined mass with calcification,high attenuation lesion on plain CT,and marked solid part enhancement on contrast CT.
4.Preparation of cholesterol and glycerol reference materials in cyclodextrin aqueous solution
Weiyan ZHOU ; Songlin YU ; Jie ZENG ; Donghuan WANG ; Tianjiao ZHANG ; Ying YAN ; Jiangtao ZHANG ; Qinghui MENG ; Yufei WANG ; Wenxiang CHEN ; Chuanbao ZHANG
Chinese Journal of Laboratory Medicine 2017;40(7):520-525
Objective Preparation of aqueous reference materials for cholesterol and glycerol.Methods Study on reference materials.The certified reference materials GBW09203b and GBW09149 were weighed accurately and dissolved into 20% of methyl cyclodextrin aqueous solution to prepare six kinds of candidate reference materials of cholesterol and glycerol according to the concentration.The materials were tested for homogeneity and stability using routine methods.The reference methods of isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) were used to determine the concentration of cholesterol and glycerol to evaluate the accuracy of the certified values.Meanwhile, the blank verification test was carried out.The expanded uncertainty was the combination of standard uncertainty of measurement, unhomogeneity and instability.Results It showed that the six candidate reference materials were homogeneous and stable for at least 1 year at-70 ℃ and-20 ℃.The certified values (reference value ± expanded uncertainty,mmol/L) were as follows,for cholesterol:0.65±0.01,1.31 ±0.01,2.57±0.02,5.21±0.06,7.71±0.08,10.24±0.06;for glycerol:0.29±0.01,0.58±0.01,1.22±0.02,2.24±0.02,3.46±0.04,4.52 ±0.04.The results of reference methods were consistent with the certified values.Blank validation tests showed that the concentration of the analytes would not be affected by the reagent and the blank matrix.Conclusions Certified reference materials for cholesterol and glycerol in aqueous solution have been prepared successfully.These materials are homogeneous and stable, and the certified values are reliable.Therefore the materials have been approved to be the Certificate Reference Materials of GBW 09823, GBW 09824, GBW 09825, GBW09826, GBW09827 and GBW 09828.
5.Preparation of reference materials of total thyroxine
Weiyan ZHOU ; Songlin YU ; Donghuan WANG ; Jing WANG ; Jie ZENG ; Tianjiao ZHANG ; Jiangtao ZHANG ; Feng ZHAO ; Nan QIN ; Qinghui MENG ; Mo WANG ; Wenxiang CHEN ; Chuanbao ZHANG
Chinese Journal of Laboratory Medicine 2016;(1):40-44
Objective To prepare the serum reference materials for total thyroxine .Methods Individual blood samples were collected from 13 healthy donors (7 males and 6 females) aged from 20 to 50 years old, and the sera were separated and mixed into 4 serum pools according to the concentration of thyroxine.The materials were tested for homogeneity and stability using routine methods .The method of isotope dilution liquid chromatography tandem mass spectrometry ( ID-LC/MS/MS) was used to determine the concentration of thyroxine .The candidate reference materials were also measured by four conventional methods to analyze the commutability of the materials .Results It showed that the four candidate reference materials were homogeneous and commutable in four conventional methods and they were tested to be stable for at least 1 year at -70 ℃using the isochronous stability study .The certified values ( reference value ± expanded uncertainty ,nmol/L) were:75.9 ±1.8,105.3 ±2.2,114.7 ±2.1 and 187.4 ±2.9.Conclusions Certified reference materials for serum thyroxine have been prepared .These materials have been approved to be the Certificate Reference Materials of GBW 09127,GBW 09128,GBW 09129 and GBW 09130.
6.Experimental study of serum SM22 in the diagnosis of acute intestinal ischemia
Haikun LI ; Minhua WANG ; Xiaoqing ZHOU ; Qinghui YIN ; Bin YE ; Xiangfu ZENG ; Xiaoping LIU ; Xiansen ZHU ; Xiangtai ZENG
Chinese Journal of General Surgery 2019;34(2):151-153
Objective To evaluate smooth muscle protein of 22 kDa (SM22) in the diagnosis of acute intestinal ischemia.Methods 96 healthy adult SD rats were evenly divided into experimental group and control group,with each group subdivided into 6 subgroups,subject respectively to superior mesenteric artery ligation or sham operation.The venous blood samples were extracted from each group rats' right heart atO.5,1,2,4,8,12 h after the operation,for SM22 testing and small intestines tissues for direct immunofluorescence staining of SM22.Results The serum SM22 concentration reached a peak at 4 h (265 ± 15) mg/L,then gradually decreased (P < 0.05).The I-FABP was mainly expressed in the epithelium of intestinal mucosa.During the 4 hours of intestinal ischemia,The number of SM22 positive particles did not change.After 4 hours,the number of SM22 positive granules had gradually decreased compared with the control group (all P < 0.05).Conclusion SM22 mainly exists in the smooth muscle of intestinal,during the ischemic necrosis of the intestinal muscle layer SM22 leaks into blood stream,resulting in high serum levels of SM22 facilitating early diagnosis of acute intestinal ischemia.
7.Methodological evaluation of nephelometric assay for the determination of IgA residues in human intravenous immunoglobulin
Mingxia HOU ; Yan WU ; Meiling DING ; Xi′e ZHEN ; Qinghui FU ; Huan ZENG ; Wenjie XIE ; Zhan ZHANG ; Yunjia ZHANG
Chinese Journal of Blood Transfusion 2021;34(10):1090-1093
【Objective】 To establish and evaluate a nephelometric assay for the determination of immunoglobulin A (IgA) residues in human intravenous immunoglobulin(IVIG). 【Methods】 BN ProSpec© automatic protein analyzer and its supporting immunoglobulin A determination kit (nephelometry) produced by German Siemens and the national standard of human IgA were used to establish the nephelometric assay to determine IgA residue in test products and verify the methodology. The test products include IVIG (pH4) prepared by low-temperature ethanol protein separation process and a novel IVIG prepared by chromatography. 【Results】 The average deviation of three calibration curves for IgA residues determination by the nephelometric assay were 1.08%, 0.95% and 1.54%,, and the three deviations of the quality control were 4.00%, -2.30% and -0.20%, respectively, which indicated good calibration and quality control. In the specificity test, the average recovery rates of IgA for reference substance 1 containing 100g/L maltose and reference substance 2 containing 20g/L glycine were 102.7% and 105.8%, respectively. The relative standard deviation (RSD) values of the repeatability tests of the two test products were 3.9% and 1.9%, and the RSD values of the intermediate precision test were 3.6% and 2.3%, respectively.The difference values at each time point in the durability test of test products′ storage time were all less than 10%, and the RSD values of the two test products in the durability test of kits of different batches were 2.8% and 2.2%, respectively. In the accuracy test, the average recovery rates of IVIG (pH4) added to the standard were 94.2%, 101.7% and 96.2%, respectively, and the average recovery rates of the novel IVIG added to the standard were 102.8%, 106.3% and 99.7%, respectively. The average recovery rate of the limit quantification test was 101.0%, and the RSD was 4.0%. 【Conclusion】 Nephelometric assay has the advantages of strong specificity, high precision and accuracy, good repeatability, simple and rapid operation, and automation, and can be used for the determination of IgA residue in IVIG (pH4) and novel IVIG products.