1.Use of plastic valve in cholangiojunostomy
Gao GU ; Yongquan SONG ; Qingfeng JIN ;
Chinese Journal of General Surgery 1997;0(06):-
Reflux cholangitis is a common complicatian follawing cholangio-jejunostomy,During a period between July 1981 and June 1994 the authors have performed plastic valve in 116 cases undergo- ing Cholangrojunostomy adding a plastic valve to each of three forms of cholang iojejunostomy that was Y-shape,loop-shape,and interposition-shape in Order tO prevent reflux.There was no inhospital mor- tality and fistula,and symptoms related to biliary tract disappeared in 92 cases(79.3%)during fouow- up.
2.Stress analysis of distal-extension removable partial dentures supported by mini implants
Qingfeng HUANG ; Wenzhong JIN ; Fuqiang ZHANG ; Wen CUI ; Dongmei WANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1295-1298
Objective To analyse the stress distribution of distal-extension removable partial dentures supported by mini implants. Methods The finite element analysis models of conventional removable partial dentures ( CRPD) and mini implants supported removable partial dentures (ISRPD) were established by modular denture model. The stress distribution of abutments and supporting tissues was compared by finite element analysis software Abaqus 6.5.Results Under vertical loading, the stress of abutment teeth, mucosa of edentulous region and alveolar bone of ISRPD model was lower than that of CRPD model. Under oblique loading, the stress of each part of CRPD model and alveolar bone of ISRPD model significantly increased, while that of abutment teeth and parodontium of ISPRD model decreased. Conclusion The distal-extension removable partial dentures supported by mini implants work well in protecting the abutments and supporting tissues.
3.Stress analysis of precision attachment dentures for mandibular distal-extension edentulous cases
Qingfeng HUANG ; Wenzhong JIN ; Fuqiang ZHANG ; Wen CUI ; Dongmei WANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1291-1294
Objective To analyse the stress distribution of precision attachment dentures used in distal-extension edentulous cases. Methods The finite element models of conventional removable partial dentures and precision attachment dentures were established by modular denture model, and the models of precision attachment dentures were established with 4┬4 as one abutment or 43┬34 as two abutments. The stress distribution of abutments and supporting tissues was compared by finite element analysis software Abaqus 6.5.Results Under vertical loading or oblique loading, the stress of abutments and supporting tissues from attachment dentures with two abutments was significantly lower than that from attachment dentures with one abutment. The stress of conventional removable partial dentures significantly increased under oblique loading. Conclusion It is reasonable for the design of attachment dentures with two abutments for mandibular distal-extension edentulous cases.
4.Comparison of stress distribution on telescopic denture and clasp-retention denture for bilateral free-ended cases
Bin WEI ; Jie CHEN ; Qingfeng HUANG ; Wenzhong JIN ; Fuqiang ZHANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1288-1290
Objective To establish three dimensional finite element model libraries of telescopic dentures and removable partial dentures by means of model libraries, and compare the characteristics of stress distribution among three prostheses. Methods Normal model libraries were imported and edited, and models of bilateral free-ended cases were established. Based on the model libraries of fixed partial dentures and removable partial dentures, the finite element models of telescopic dentures and removable partial dentures with medial or distal occlusal rest were established using softwares such as DELL Precision Graphics Workstation, UG 5.0, HyperMesh 7.0 and Abaqus 6.5, then finite element stress analysis was performed. Results The stress distribution on abutment root, parodontium, alveolar mucosa and alveolar bone was uniform. The maximum value of stress on the abutment root (6.205 Mpa) was much less than those of two removable partial dentures (18.41 Mpa and 34.49 Mpa). Conclusion For bilateral free-ended cases, the telescopic denture design is uniform in stress distribution with less stress on abutment root, which is healthy to the abutment root and surrounding tissues.
5.Model establishment and stress analysis of telescopic crown-retained removable partial dentures
Bin WEI ; Qingfeng HUANG ; Wenzhong JIN ; Jie CHEN ; Fuqiang ZHANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1285-1287
Objective To redevelop the finite element model libraries and to analyse the stress distribution of telescopic crown dentures. Methods The finite element model libraries were redeveloped based on the model libraries of normal dentition, fixed partial denture and removable partial denture. With the help of softwares such as DELL Precision Graphics Workstation, UG 5.0, HyperMesh 7.0 and Abaqus 6.5, the telescopic denture models on the bilateral free-ended case were imported and edited, then the finite element stress analysis was performed. Results The models were easily established. The maximum value of stress and its distribution on abutment root, periodontal membrane, alveolar mucosa, alveolar bone and dental prostheses were observed and studied by the finite element stress analysis. Conclusion The way to establish models of telescopic crown dentures by model libraries is feasible and reliable.
6.Stress analysis of distal-extension prosthetics with mesial and distal occlusal rest
Wenzhong JIN ; Qingfeng HUANG ; Bin WEI ; Fuqiang ZHANG ; Wen CUI ; Chengtao WANG
Journal of Shanghai Jiaotong University(Medical Science) 2009;29(11):1282-1284
Objective To investigate the stress distribution in the abutment and supporting tissues of distal-extension removable partial dentures with mesial and distal occlusal rest under loading. Methods A modular denture model was used to build a model of mandibular dentition defect ( 765┬567 loss) with HyperMesh 7.0 software. Prosthetics with mesial (M model) and distal occlusal rest (D model) were designed with UG 5.0 software, and the finite element models were completed with HyperMesh 7.0 software. The stress distribution was analyzed in the abutment and supporting tissues of distal-extension removable partial dentures with mesial and distal occlusal rest when bilateral vertical forces were applied. Results Compared with M model, D model provided much larger maximum stress in abutments and periodontal membrane. Stress of D model mainly concentrated on roots of 4┬4 , while that of M model uniformly distributed on roots of 43┬34 . The maximum stress of M model was significantly larger than that of D model on the mucosa of edentulous region. The maximum stress on alveolar bone of two models' edentulous region was equal, while the stress of M model distributed more widely. Conclusion It is prior to select mesial occlusal rest in distal-extension removable partial dentures.
7.Ultrasound-guided multiple-spot sector stereotaxis in unipolar cooling cycle radiofrequency ablation of hepatic carcinomas
Dandan LI ; Jin HUANG ; Wenlun LI ; Zhiwen HOU ; Futian DU ; Qingfeng KONG
Chinese Journal of Medical Imaging Technology 2009;25(12):2282-2285
Objective To assess the effect of ultrasound-guided multiple-spot sector stereotaxis in unipolar cooling cycle radiofrequency ablation of hepatic carcinomas. Methods Ninety-six patients with 112 liver malignancies were treated with ultrasound-guided percutaneous radiofrequency ablation using multiple-spot sector stereotaxis method. Conventional multi-section ultrasound scanning was performed to determine the exact location of tumors. Contrast enhanced ultrasound (CEUS) was performed 15 minutes after treatment to determine whether the tumors were completely inactivated. Contrast enhanced CT (CECT) and CEUS were performed 1 month after treatment to evaluate the therapeutic effect. Results A total of 293 punctures were performed for 112 tumors, technical successful rate with a successful rate of puncture was 91.81% (269/293). CEUS showed no blood flow signals in the tumors 15 minutes after therapy. One month after therapy, CT showed the volume of tumors shrunk, no enhancement was found in 100 tumors (100/112, 89.29%), while partial reinforcement was noticed in 12 tumors (10.71%). Meanwhile, CEUS showed no enhancement in 90 tumors (90/103, 87.38%), when partial reinforcement was noticed in 13 tumors (13/103, 12.62%). Conclusion Ultrasound-guided multiple-spot sector stereotaxis unipolar cooling cycle radiofrequency ablation is an effective and reliable method to treat hepatic carcinomas.
8.Pacilitaxel in association with gemcitabine for anthracycine-resistant advanced breast cancer
Qingfeng FANG ; Zhihua SHAO ; Wei LIN ; Jing JIN ; Yueyuan JIANG ; Ruiyuan LU
Chinese Journal of General Surgery 2001;0(10):-
Objective To evaluate the effect and safety of combined therapy of paclitaxel and gemcitabine for anthracycine(ANT)-resistant advanced breast cancer(ABC).MethodsFrom May 2000 to Aug 2004,twenty six patients with ANT-resistant ABC were treated with this combined regime.The median chemotherapy cycles were 2.5(range from 2 to 3 cycles).ResultsOf 26 patients, there were 3 complete(11.5%) and 11 partial(42.3%) responses for an overall response rate of 53.8%. Eight cases remained stable (30.8%) and 4 progressive (15.4%). The median survival time was 18 months. The median time to progression was 7 months. The main toxic reaction included bone marrow depression, liver function damage, alopecia, mucositis and peripheral neurotoxicity. ConclusionsCombined medication of gemcitabine and paclitaxel is effective in therapy of ANT-resistant advanced breast cancer with acceptable toxicity.
9.Survivin as a factor of radioresistance to high-LET carbon ions in human hepatoma SMMC.7721 cells
Xiaodong JIN ; Li GONG ; Qiang LI ; Jifang HAO ; Ping LI ; Qingfeng WU ; Ling HE ; Xinguo LIU ; Zhongying DAI
Chinese Journal of Radiological Medicine and Protection 2009;29(1):1-4
Objective To investigate the influences of survivin down-regulation on cell G2/M phase arrest,apeptosis and sensitivity to carbon ion irradiation. Methods Small interfering RNA (siRNA) targeting survivin mRNA was designed, in vitro chemo-synthesized and transfected into SMMC-7721 cells. Survivin mRNA expression in SMMC-7721 cells was measured by real-time PCR, and the apeptotic rates by Annexin-FTTC at 24 and 48 h after transfection. Cell G2/M phase arrest after transfection was assessed with flow eytometry as well. Cellular sensitivity to high-LET carbon ions was determined by means of colony-forming assay. Results The expressions of survivin at mRNA level were down-regulated to be 59% and 39% in relation to the non-treated cells at 24 and 48 h after siRNA transfeetion, respectively. G2/M phase arrest in SMMC-7721 cells at 24 h after transfection was observed while much more obvious at 48 h. The apeptotic rate of SMMC-7721 cells was 21.41 % at48 h after survivin siRNA transfection, which was significantly higher than that of the cells transfected with negative siRNA. Moreover, a decreased clonogenic survival in siRNA treated group was shown. Conclusion Down-regulation of survivin gene expression in SMMC-7721 cells by siRNA could effectively induce cell apeptosis and G2/M phase arrest, and enhance the cellular radiosensitivity to high-LET heavy ions.
10.The effects of backpack loading on the gait and corresponding compensatory strategy.
Ming WU ; Linhong JI ; Dewen JIN ; Qingfeng ZHU ; Rencheng WANG
Journal of Biomedical Engineering 2003;20(4):574-579
This study was designed to determine the effect of backpack loading on the gait pattern and corresponding compensatory strategy, which is important to the balance control of biped robot and military training. Five healthy subjects were instructed to walk at their preferred speed on level pathway taking three different loads i.e. 6 kg, 12 kg and 25 kg, on their backs. The results showed that the gait pattern was apparently influenced, and the dominant effects were found to be the flexion of hip, knee joints and pitch angle of torso. The stride speed decreased apparently with loading on their backs, but the stride length showed less changes. Besides, the responses to taking loads might be influenced by the strength of body. An apparent multi-joints coordination motor mode was employed to compensate the influences of loading, however, their contributions are different; hip, knee joints and torso pitch made dominant contributions to the compensation while ankle joints made minor. The anterior pitch of upper torso could be employed to adjust the overall center of mass while loading on their backs, the larger the magnitude of loading on their backs, the larger the anterior pitch angle of torso. After the heel touched the ground, the flexion of hip and knee joints were effective for the shock absorption, which means that the stiffness of hip and knee joints can be used to absorb the shock and avoid the trauma of each joints.
Adult
;
Ankle Joint
;
physiology
;
Back
;
physiology
;
Gait
;
physiology
;
Hip Joint
;
physiology
;
Humans
;
Knee Joint
;
physiology
;
Male
;
Weight-Bearing
;
physiology