1.The mechanism of action of valsartan studied by HPLC-TOF/MS.
Wen-qing YANG ; Yun-lun LI ; Hai-qiang JIANG
Acta Pharmaceutica Sinica 2015;50(7):875-881
High performance liquid chromatography-time-off-flight mass spectrometer (HPLC-TOFMS) technology coupled with partial least squares discriminant analysis (PLS-DA) processed by SIMCA-P software was applied to investigate serum endogenous metabolites alternations of valsartan in spontaneous hypertension rats (SHR). And MetPA platform was used to connect identified potential biomarkers in corresponding metabolic pathways to find possible therapeutic mechanism of valsartan. Valsartan significantly declined the blood pressure of SHRs (P < 0.05) at fourth week. The metabolic profiling significantly changed and four metabolites involved in G protein-coupled pathway were identified. Metabolomics is able to detect holistic and microcosmic alternations in organism, so as to elucidate therapeutic mechanism of drugs.
Animals
;
Biomarkers
;
blood
;
Blood Pressure
;
Chromatography, High Pressure Liquid
;
Discriminant Analysis
;
Least-Squares Analysis
;
Mass Spectrometry
;
Metabolome
;
Metabolomics
;
Rats
;
Rats, Inbred SHR
;
Valsartan
;
pharmacology
9.The study of sweep pattern visual evoked potential acuity(SPVEP-A)and international standard visual acuity in amblyopic children
Yun-Wei FAN ; Xiao-Qing LI ; Gui-Fen TIAN ;
Ophthalmology in China 1993;0(04):-
Objective To evaluate the clinical application of sweep pattern visual evoked potential in assessing visual acuity (SPVEP-A)of amblyopic children.Design Prospective clinical study.Participants 80 patients(148 case)of amblyopic children and 26 children(52 case)with normal vision.Methods The correlation were analysed of SPVEP-A and E acuity in 80 amblyopic children and of SPVEP-A and PVEP-A in 26 children of normal visual.SPVEP-A was recorded with UTAS-E 3000(LKC)using gratings of 25 differ- ent spatial frequency from 0.2 to 18.8cpd as stimulus.The response were averaged and DFT on the monitor display.SPVEP-A was de- termined by extrapolate to 0 response amplitude.Both transient PVEP-A and SPVEP-A were examined in 26 normal children.The ob- jective visual acuity in PVEP were determined with the highest spatial frequency which evoked a recognizable response.Main Out- come Measures SPVEP-A,PVEP-A and E acuity.Results SPVEP-A were from 0.35 to 0.9 among 80 patients with corrected E acu- ity from 0.1 to 0.8.The correlation coefficient of SVEP-A-I with E acuity was 0.602 .The correlation coefficient of SPVEP-A.between reproducibility detection was 0.448.The correlation between SPVEP-A and E acuity in amblyopic slightly was higher than middle and severe amblyopia(r=0.773 vs r=0.590).In 26 normal children a correlation coefficient of 0.679 was obtained between E acuity anti PVEP-A but 0.424 between E acuity and SPVEP-A.Higher evaluation or lower evaluation of E acuity was found in SPVEP-A in this study.Acuity was upostimated in lower scope of E acuity and underestimated in higher scope of E acuity.The reproducibility and vari- ation were not satisified.Conclusion The sweep VEP is a objective method of amblyopic screening.There is significant positive corre- lation between SPVEP-A and E,but its variability is more great,so we should improve its stability and positive rate uheriorly.