1.Selective Extraction of Low Molecular Weight Proteins by Mesoporous Silica Particles with Phenyl-Modified Internal and Alkyl-diol-Modified External Surfaces
Yanxia QI ; Qiancheng ZHAO ; Zhibo LI ; Wei LI ; Qiukuan WANG ; Yafeng GUAN
Chinese Journal of Analytical Chemistry 2014;(8):1083-1087
Selective extraction of low molecular weight ( LMW) proteins and peptides from complex biological samples plays an important role in the discovery of useful biomarkers and signaling molecules. It is demonstrated that the unique pore structure of mesoporous material makes it efficient to enrich LMW proteins and peptides from complex matrixes. In this study, a mesoporous material, alkyl-diol@ phenyl-SiO2 , with modified exterior ( alkyl-diol group) and interior ( phenyl group) surfaces, was synthesized by co-condensation and post-grafting, and its characteristic was evaluated by FTIR and MS. The LMW proteins and peptides enriched by the alkyl-diol@phenyl-SiO2 mesoporous material could be easily eluted by organic solvents, which was compatible with the following detection by mass spectrometry ( MS ) . This new mesoporous material exhibited good selectivity for the extraction of LMW proteins and peptides ( less than 10 kDa) from complex biological samples.
2.The gas discharge visualization (GDV) order parameter model based on the principle of mastering both permanence and change
XIN Yu ; ZHANG Lei ; ZHAO Qiancheng ; SHE Yurong ; SHE Zhensu ; SONG Shuna
Digital Chinese Medicine 2024;7(3):231-240
Methods:
This paper introduces the concept of “order parameters” and proposes a method for establishing an order parameter model of gas discharge visualization (GDV) based on the principle of “mastering both permanence and change (MBPC)”. The method involved the following three steps. First, average luminous intensity () and average area () of the GDV images were calculated to construct the phase space, and the score of the health questionnaire was calculated as the health deviation index (H). Second, the k-means++ clustering method was employed to identify subclasses with the same health characteristics based on the data samples, and to statistically determine the symptom-specific frequencies of the subclasses. Third, the distance (d)
3.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
4.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
5.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
6.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
7.Predictive value of CT imaging features in preoperative high-risk group of childhood hepatoblastoma
Gongwei ZHANG ; Cailei ZHAO ; Na LUO ; Diangang FANG ; Longwei SUN ; Huan ZHANG ; Meng YI ; Yungen GAN ; Qiancheng LI
Chinese Journal of Radiology 2021;55(9):981-986
Objective:To investigate the value of CT findings of childhood hepatoblastoma (HB) in predicting preoperative tumor risk stratification.Methods:Totally 46 children with HB confirmed by surgery and pathology were retrospectively enrolled from October 2010 to October 2019 in Shenzhen Children′s Hospital and Xuzhou Children′s Hospital. The preoperative abdominal plain CT and three-phasic contrast-enhanced CT with complete clinical files were evaluated. According to the clinical risk stratification established by the multidisciplinary diagnosis and treatment consensus for children with HB, the HB children were divided into high-risk group and non-high-risk group with 16 and 30 cases respectively. The maximum diameter of tumor, relative tumor volume index, cystic change or necrosis, bleeding, calcification, fibrous septations, tumor rupture, liver capsule retraction and subcapsular effusion were evaluated. Enhancement percentage and enhancement index on arterial, venous and delayed phases of each tumor were measured and calculated. Pearson′s χ 2 test or Fisher′s exact test were used to compare the differences in gender and lesion morphological characteristics between the high-risk group and the non-high-risk group. Two independent sample t test or Mann-Whitney U test were used to compare the differences in age, gestational age, birth weight, α-fetoprotein, platelets, maximum diameter of tumor, relative tumor volume index and CT parameters of the lesion between the two groups. Statistically significant features were included in the binary logistic regression analysis and independent predictors related to high-risk group were obtained. The ROC curve was used to determine the critical value of the high-risk group. Results:There were statistically significant differences in age, maximum diameter of tumor, relative tumor volume index and tumor rupture between the high-risk group and the non-high-risk group (all P<0.05). The logistic regression analysis showed that the maximum diameter of tumor (OR=1.906, P=0.004) and tumor rupture (OR=16.558, P=0.005) were risk factors of the high-risk group. Based on ROC curve, the optimum cut-off point of maximum diameter of tumor to predict high-risk group was 10.5 cm. Tumor rupture, maximum diameter of tumor and maximum diameter of tumor combined with tumor rupture for predicting the incidence of high-risk group resulted in the area under the curve of 0.744, 0.807 and 0.879, respectively. The sensitivity and specificity of maximum diameter of tumor combined with tumor rupture were 75.0% and 96.7%, respectively. Conclusion:The age of onset in high-risk group is relatively older. The maximum diameter of tumor greater than 10.5 cm accompanied by tumor rupture can be regarded as a high-risk sign.
8.Multilevel Pedicle Subtraction Osteotomy for Correction of Thoracolumbar Kyphosis in Ankylosing Spondylitis: Clinical Effect and Biomechanical Evaluation
Xin LV ; Yelidana NUERTAI ; Qiwei WANG ; Di ZHANG ; Xumin HU ; Jiabao LIU ; Ziliang ZENG ; Renyuan HUANG ; Zhihao HUANG ; Qiancheng ZHAO ; Wenpeng LI ; Zhilei ZHANG ; Liangbin GAO
Neurospine 2024;21(1):231-243
Objective:
To compare the clinical outcomes and biomechanical characteristics of 1-, 2-, and 3-level pedicle subtraction osteotomy (PSO), and establish selection criteria based on preoperative radiographic parameters.
Methods:
Patients undergone PSO to treat ankylosing spondylitis from February 2009 to May 2019 in Sun Yat-sen Memorial Hospital of Sun Yat-sen University were enrolled. According to the quantity of osteotomy performed, the participants were divided into group A (1-level PSO, n = 24), group B (2-level PSO, n = 19), and group C (3-level PSO, n = 11). Clinical outcomes were assessed before surgery and at the final follow-up. Comparisons of the radiographic parameters and quality-of-life indicators were performed among and within these groups, and the selection criteria were established by regression. Finite element analysis was conducted to compare the biomechanical characteristics of the spine treated with different quantity of osteotomies under different working conditions.
Results:
Three-level PSO improved the sagittal parameters more significantly, but resulted in longer operative time and greater blood loss (p < 0.05). Greater stress was found in the proximal screws and proximal junction area of the vertebra in the model simulating 1-level PSO. Larger stress of screws and vertebra was observed at the distal end in the model simulating 3-level PSO.
Conclusion
Multilevel PSO works better for larger deformity correction than single-level PSO by allowing greater sagittal parameter correction and obtaining a better distribution of stress in the hardware construct, although with longer operation time and greater blood loss. Three-level osteotomy is recommended for the patients with preoperative of global kyphosis > 85.95°, T1 pelvic angle > 62.3°, sagittal vertical alignment > 299.55 mm, and pelvic tilt+ chin-brow vertical angle > 109.6°.
9.Multilevel Pedicle Subtraction Osteotomy for Correction of Thoracolumbar Kyphosis in Ankylosing Spondylitis: Clinical Effect and Biomechanical Evaluation
Xin LV ; Yelidana NUERTAI ; Qiwei WANG ; Di ZHANG ; Xumin HU ; Jiabao LIU ; Ziliang ZENG ; Renyuan HUANG ; Zhihao HUANG ; Qiancheng ZHAO ; Wenpeng LI ; Zhilei ZHANG ; Liangbin GAO
Neurospine 2024;21(1):231-243
Objective:
To compare the clinical outcomes and biomechanical characteristics of 1-, 2-, and 3-level pedicle subtraction osteotomy (PSO), and establish selection criteria based on preoperative radiographic parameters.
Methods:
Patients undergone PSO to treat ankylosing spondylitis from February 2009 to May 2019 in Sun Yat-sen Memorial Hospital of Sun Yat-sen University were enrolled. According to the quantity of osteotomy performed, the participants were divided into group A (1-level PSO, n = 24), group B (2-level PSO, n = 19), and group C (3-level PSO, n = 11). Clinical outcomes were assessed before surgery and at the final follow-up. Comparisons of the radiographic parameters and quality-of-life indicators were performed among and within these groups, and the selection criteria were established by regression. Finite element analysis was conducted to compare the biomechanical characteristics of the spine treated with different quantity of osteotomies under different working conditions.
Results:
Three-level PSO improved the sagittal parameters more significantly, but resulted in longer operative time and greater blood loss (p < 0.05). Greater stress was found in the proximal screws and proximal junction area of the vertebra in the model simulating 1-level PSO. Larger stress of screws and vertebra was observed at the distal end in the model simulating 3-level PSO.
Conclusion
Multilevel PSO works better for larger deformity correction than single-level PSO by allowing greater sagittal parameter correction and obtaining a better distribution of stress in the hardware construct, although with longer operation time and greater blood loss. Three-level osteotomy is recommended for the patients with preoperative of global kyphosis > 85.95°, T1 pelvic angle > 62.3°, sagittal vertical alignment > 299.55 mm, and pelvic tilt+ chin-brow vertical angle > 109.6°.
10.Multilevel Pedicle Subtraction Osteotomy for Correction of Thoracolumbar Kyphosis in Ankylosing Spondylitis: Clinical Effect and Biomechanical Evaluation
Xin LV ; Yelidana NUERTAI ; Qiwei WANG ; Di ZHANG ; Xumin HU ; Jiabao LIU ; Ziliang ZENG ; Renyuan HUANG ; Zhihao HUANG ; Qiancheng ZHAO ; Wenpeng LI ; Zhilei ZHANG ; Liangbin GAO
Neurospine 2024;21(1):231-243
Objective:
To compare the clinical outcomes and biomechanical characteristics of 1-, 2-, and 3-level pedicle subtraction osteotomy (PSO), and establish selection criteria based on preoperative radiographic parameters.
Methods:
Patients undergone PSO to treat ankylosing spondylitis from February 2009 to May 2019 in Sun Yat-sen Memorial Hospital of Sun Yat-sen University were enrolled. According to the quantity of osteotomy performed, the participants were divided into group A (1-level PSO, n = 24), group B (2-level PSO, n = 19), and group C (3-level PSO, n = 11). Clinical outcomes were assessed before surgery and at the final follow-up. Comparisons of the radiographic parameters and quality-of-life indicators were performed among and within these groups, and the selection criteria were established by regression. Finite element analysis was conducted to compare the biomechanical characteristics of the spine treated with different quantity of osteotomies under different working conditions.
Results:
Three-level PSO improved the sagittal parameters more significantly, but resulted in longer operative time and greater blood loss (p < 0.05). Greater stress was found in the proximal screws and proximal junction area of the vertebra in the model simulating 1-level PSO. Larger stress of screws and vertebra was observed at the distal end in the model simulating 3-level PSO.
Conclusion
Multilevel PSO works better for larger deformity correction than single-level PSO by allowing greater sagittal parameter correction and obtaining a better distribution of stress in the hardware construct, although with longer operation time and greater blood loss. Three-level osteotomy is recommended for the patients with preoperative of global kyphosis > 85.95°, T1 pelvic angle > 62.3°, sagittal vertical alignment > 299.55 mm, and pelvic tilt+ chin-brow vertical angle > 109.6°.