1.Comparison of five automated 25OHD immunoassays and liquid chromatography tandem mass spectrometry method
Songlin YU ; Huiling FANG ; Xinqi CHENG ; Ruiping ZHANG ; Jianhua HAN ; Xuzhen QIN ; Liangyu XIA ; Wei SU ; Qian CHEN ; Ling QIU
Chinese Journal of Laboratory Medicine 2015;(7):475-479
Objective To compare the concordance of five automated 25OHD immunoassays with liquid chromatography tandem mass spectrometry method ( LC-MS/MS) .Methods During May to July in 2014, 245 clinical serum samples that requested 25OHD tests were selected, with a total 25OHD range of 2.8 ng/ml-64.0 ng/ml, in which 154 samples did not contain 25OHD2 and 91 samples contains both 25OHD2 and 25OHD3 .To used a LC-MS/MS method that built in our laboratory to measure 25OHD, five commercial automated chemiluminescent immunoassays from Abbott Diagnostics ( A ) , DiaSorin LIASON (B), IDS-iSYS(C), Roche Diagnostics(D), and Siemens ADVIA Centaur(E).Taking the reference method LC-MS/MS as a standard , to compared the concordance and performance of the five automated 25OHD immunoassays.And used the commonly accepted cutoffs for 25OHDdeficiency (<20 ng/ml), and insufficiency ( 20 -30 ng/ml ) , and sufficiency (≥30 ng/ml ) to compare the uniformity of different methods .Statistical analysiswere performed by MedCalc software , Passing & Bablok regression , Bland &Altaman plots and Box and whisker plots were performed to compare the differences of the methods .Results The medium ( range:2.5% -97.5%) 25OHD of the 245 serum samples of the six methods was 23.5 (5.8-44.2) ng/ml(LC-MS/MS),20.6 (7.1-43.5)ng/ml(A),19.0 (5.4-38.0) ng/mL (B),23.0 (10.0-38.1) ng/ml(C),20.1 (5.1 -46.0) ng/ml (D),31.3 (12.3 -71.1) ng/ml (E), respectively .Passing and Bablok regression showed that method B had the best correlation coefficient with LC-MS/MS (r=0.894), while methods A, C and D had relatively small bias compared withLC-MS/MS and method E had the large bias .If the serum samples did not contain 25OHD2 , all the five automated immunoassays correlated well with LC-MS/MS with a correlation coefficient higher than 0.84, and B has the best correlation with LC-MS/MS ( r=0.930 ) .While all the correlation coefficient between immunoassays and LC-MS/MS decreasedwhen analyzing the samplescontaining 25OHD2.Using the clinical cutoffs, A, B, C, D and E had a concordance of 68.6%, 64.9%, 67.8%, 70.6% and 51.8% compared with LC-MS/MS, respectively .Conclusions There are significant differences between different detection systems of 25OHD.All the immunoassays results were affected by the existence of 25OHD2 .The concordance of serum 25OHD resultswas poor between different methods , and it may be necessary to built exclusive cutoffs for different methods.
2.Double locking mini-plates for fixation of comminuted fracture of the first metacarpal base
Yudong GUO ; Fangyuan QIAN ; Shanzheng WANG ; Jiabin YU ; Liangyu MA ; Jun JIA ; Chen WANG
Chinese Journal of Orthopaedic Trauma 2018;20(3):254-257
Objective To investigate the clinical efficacy of double locking mini-plates for fixation of the comminuted fracture of the first metacarpal base.Methods Twenty-four patients with the comminuted fracture of the first metacarpal base were treated by double locking mini-plates in our hospital from January 2013 to January 2016.They were 17 males and 7 females,from 27 to 65 years of age (average,33.5 years).By the Green classification,6 cases were type Ⅰ,13 cases type Ⅱ and 5 cases type Ⅲ.All the fractures were closed.The average time from injury to surgery was 2.3 days (from 8 hours to 7 days).After open reduction via the palmar-radial incision,the fracture was fixated with 2 mini-plates,one locking T-plate on the radial side and one straight locking plate on the dorsal side.Fracture healing time,pain and finger function were followed up postoperatively.Visual analogue scale (VAS) was used to evaluate the pain at 12 months and scoring for digital total range of motion to assess the function of the affected finger at the final follow-up.Results The 24 patients obtained follow-up for 8 to 28 months (average,18 months).All the Fractures healed after 9 to 12 weeks (average,10.5 weeks).The VAS scores at 12 months ranged from 0 to 3 (average,1.5).The function of the affected finger at the final follow-up was excellent in 20 cases and good in 4,giving an excellent to good rate of 100%.Two patients complained of pain after frequent motion of the finger.No complications like skin problems,dislocation of the first metacarpal base,implant failure,necrosis or irritation of the soft tissue were observed during follow-up.No angulation or rotational deformity occurred after fracture union.Conclusion Fixation with double locking mini-plates can effectively treat comminuted fractures of the first metacarpal base,because it can provide rigid stabilization which promotes early functional exercise of the finger,and prevents joint stiffness as well.
3.Diagnostic value of high-frequency color ultrasound for different types of thyroid nodules during healthy examinations
Xiaolan QIAN ; Yanjun QIAN ; Liqun SHI ; Chengshuang HU ; Liangyu WU
Chinese Journal of Radiological Health 2022;31(4):502-506
Objective To evaluate the value of high-frequency color ultrasound for different types of thyroid nodules during healthy examinations. Methods A total of 150 subjects with ultrasound diagnosis of thyroid nodule abnormality were enrolled. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ultrasound diagnosis for differentiating benign and malignant thyroid nodules were evaluated with histopathological examinations of surgical thyroid specimens as a gold standard. Results A single thyroid nodule was found in all patients, and histopathological examinations identified 102 benign thyroid nodules and 48 malignant nodules. Microcalcification showed the highest accuracy for prediction of benign and malignant thyroid nodules (98.1%; χ2 = 45.67, P = 0.001), followed by taller than wider shape of thyroid nodule (92.1%; χ2 = 34.06, P = 0.001), central vascularity (82.0%; χ2 = 13.29, P = 0.001), halo (76.0%; χ2 = 6.15, P = 0.008) and hypoechogenicity (70.3%; χ2 = 10.63, P = 0.001). In addition, ultrasound diagnosis showed a 100.0% sensitivity, a 94.1% specificity, a 88.9% positive predictive value, a 100.0% negative predictive value and a 96.0% accuracy for differentiation between benign and malignant thyroid nodules (χ2 = 41.830, P < 0.001). Conclusion High-frequency color ultrasound has a high diagnostic accuracy for differentiating benign and malignant thyroid nodules, and microcalcification and taller than wider shape of thyroid nodule exhibit high values for predicting the malignancy of thyroid nodules.
4.Survey for variation of prevalence of hyperuricemia and its correlations with blood glucose and lipid in healthy adults receiv-ing physical examination at Peking Union Medical College Hospital from 2012 to 2017
Danchen WANG ; Yicong YIN ; Songlin YU ; Xiuzhi GUO ; Lian HOU ; Honglei LI ; Tingting YOU ; Qian CHENG ; Shaowei XIE ; Xinqi CHENG ; Liangyu XIA ; Ling QIU
Chinese Journal of Clinical Laboratory Science 2018;36(6):462-466
Objective To investigate the changes of prevalence of hyperuricemia ( HUA) and its correlations with blood glucose and lipid in healthy adults receiving physical examination at Peking Union Medical College Hospital (PUMCH) from 2012 to 2017. Meth-ods An observational approach was adopted for the data analysis.The test results of uric acid (UA),fasting blood glucose (FBG),to-tal cholesterol (TC),triacylglycerol (TG),low density lipoprotein cholesterol (LDL-C),high density lipoprotein cholesterol (HDL-C), creatinine (Cr) and Urea of 399 089 cases (206 881 males and 192 208 females) at PUMCH from January 2012 to December 2017 were collected and statistically analyzed.Results The total prevalence of HUA was 17.4% in which the prevalence of males was signif-icantly higher than that of females (25.6% vs 8.5%,χ2=20 234.850,P<0.01).During the years of 2012 to 2017,the prevalence of HUA was 26.5%,24.7%,28.6%,23.9%,24.8% and 24.5% in males,and 13.8%,6.3%,7.9%,6.1%,6.2% and 6.8% in females for each year respectively.The prevalence of HUA in males aged 18 to 64 years old was significantly higher than that in the age-matched fe-males (all P<0.05).However, the prevalence of HUA in males aged≥65 years old was similar to the age-matched females.There was no statistically significant difference of HUA prevalence between males and females aged ≥65 in 2013,2015,2016 and 2017 ( χ2=1.792,0.017,1.440 and 0.205 respectively;all P>0.05).The percentages of hyperlipidemia in both males and females of HUA group were higher than those of non-HUA group respectively (all P<0.01).The percentage of hyperglycemia in males of non-HUA group was higher than that of HUA group,but the percentage of hyperglycemia in females of non-HUA group was lower than that of HUA group ( all P<0.01).High levels of TC,TG and FBG were risk factors of HUA with increased OR values in increased concentrations of TC,TG and FBG,respectively.Conclusion During the recent 6 years, in healthy adults receiving physiced examination at PVMCH, the preva-lence of male HUA diagnosed was at overall high level,but the prevalence of female HUA was in decreasing and relatively stable trend. Hyperlipidemia and hyperglycemia should be the risk factors of HUA.
5.Survey of vitamin D status in apparently healthy younger and elder adults
Ruiping ZHANG ; Songlin YU ; Xinqi CHENG ; Liangyu XIA ; Qian CHENG ; Jianhua HAN ; Xuzhen QIN ; Pengchang LI ; Li'an HOU ; Ling QIU
Chinese Journal of Laboratory Medicine 2017;40(9):689-692
Objective To analyze the vitamin D status among apparently healthy younger and elder adults in Beijing based on liquid chromatography tandem mass spectrometry.Methods This is an observational study.Participants included 287 apparently healthy young adults(143 males and 144 females) with an average of (32.2 ± 6.9) years old (19-44 years).At the same time 198 middle-and elder-aged adults were recruited [90 males,108 females,(55.6 ± 7.6) years],and fasting blood samples were collected and serum were isolated.They measured 25-hydroxyvitamin D (25OHD:25OHD2 and 25OHD3)using liquid chromatography tandem mass spectrometry method.Vitamin D with deficiency,insufficiency,sufficiency and intoxication was categorized as 25OHD < 20 ng/ml,20-30 ng/ml,30-150 ng/ml,and ≥ 150 ng/ml,respectively.ALT,Ca,P,Cr,Glu,TG,TC and iPTH wereanalyzed using automatic analyzers.Statistical analysis was performed using SPSS17.0.Results The median 25OHD level in the total studied younger adults was 16.0 [2.5%-97.5%:(6.1-29.0) ng/ml] which didn't show significant difference with that of middle-and elder-aged adults.Younger males had significant higher level of 25OHD than females [17.9 (8.3-32.3) ng/ml vs.14.4 (5.4-26.4) ng/ml,Z =-4.238,P < 0.01].Of the total younger subjects,the rate of vitamin D with deficiency (< 20 ng/ml),insufficiency (20-30 ng/ml)and sufficiency (≥30 ng/ml) was 72.8%,25.1%,2.1%,respectively,while that of middle-and elderaged adults was 76.3%,21.2%,2.5% respectively,and that of younger males was 65.0%,30.8%,4.2%,respectively while that of younger females was 80.6%,19.4%,0%,respectively.Younger females had significantly higher rate of 25OHD deficiency (x2 =31.766,P < 0.01).With adjusting sex,age and BMI,serum iPTH (r =-0.264,P < 0.01) was significantly negatively correlated with 25OHD while Cr (r =0.221,P < 0.01) showed significantly positively correlation with 25OHD.Conclusion Vitamin D deficiency is prevalent in both younger and elder adults in Beijing,especially in younger females.
6.Construction and improvement of lab automation system in emergency lab
Hui WANG ; Liangyu XIA ; Lian HOU ; Ermu XU ; Qian LIU ; Ling QIU
Chinese Journal of Laboratory Medicine 2022;45(11):1123-1130
Objective:By exploring a construction and improvement system for total lab automation in emergency lab, this work aims to improve the success rates of project implementation and the effective utilization of medical resources.Methods:Firstly, clarify the short board of current solution and determine the configuration of the TLA solution which include the number of pre-analytic, post-analytic modules and analyzers by workflow and data analysis which based on the data from 16th to 22nd September 2019. Secondly, define the basic principles and design the optional solutions. Thirdly, determine the final solution based on the simulation results. Fourthly, evaluate the effectiveness of the solution by comparing the turnaroud time (TAT) before and after implementation.Result:We upgrade the system to improve the automation level of the track by add 1 online centrifuge module and upgrade the capacity of online storage module from 9 000 samples to 15 000 samples, and increase the throughput of the clinical chemistry analyzers form 2 500 tests/h to 5 400 tests/h and immunoassay analyzers from 668 tests/h to 1 320 tests/h with no more space. The 95th percentile TAT (from sample check in to validation) have 33% reduction on the premise of 9% increase on the workload of clinical chemistry and immunoassay, and it is highly consistent with the results obtained by data simulation whose 95th percentile TAT is 67 min.Conclusion:Good uasge of workflow and data analysis in the stage of solution design can help to ensure that the result can meet the expectations of the clinicians and effective utilization of medical resources.
7.Explore the reasons affecting the consistency of reference intervals established by two types of indirect methods for 34 biochemical analytes
Chaochao MA ; Yicong YIN ; Li LIU ; Qian LIU ; Xin LIU ; Ying ZHANG ; Liangyu XIA ; Ling QIU
Chinese Journal of Laboratory Medicine 2023;46(10):1083-1093
Objective:To compare the differences of reference intervals (RI) established by two types of indirect methods for 34 biochemical analytes, and to explore the possible factors that affect the consistency of the two methods.Methods:This was a retrospective study. Based on data of albumin (Alb), alkaline phosphatase (ALP), alanine aminotransferase (ALT), apolipoprotein A1(ApoA1), ApolipoproteinB (ApoB), aspartate aminotransferase (AST), calcium (Ca), cholinesterase (ChE), chloride (Cl), creatinine (Cr), high-sensitivity C-reactive protein (hsCRP), Cystatin (CysC), direct bilirubin (DBil), free fatty acid (FFA), glycated albumin(GA), gamma-glutamyltransferase (GGT), glucose (Glu), high density lipoprotein cholesterol (HDL-C), potassium (K), lactate dehydrogenase (LD), low density lipoprotein cholesterol (LDL-C), lipoprotein a [Lp (a)], sodium (Na), phosphorus (P), prealbumin (PA), superoxide dismutase (SOD), total bile acid (TBA), total bilirubin (TBil), total cholesterol (TC), total carbon dioxide (TCO 2), triglyceride (TG), total protein (TP), uric acid (UA) and urea (UR) of individuals who underwent physical examination at Peking Union Medical College Hospital from January 1, 2018 to December 31, 2019, Box-Cox algorithm was used to improve the data distribution and Tukey method was used to identify outliers. Variance component model was established, and standard deviation ratio (SDR) was calculated to determine whether the RIs of 34 biochemical analytes should be established according to age or sex The non-parametric method and kosmic algorithm were used to establish the RIs and 90% confidence intervals (CIs) of 34 biochemical analytes, and the coincidence of the 90% CIs of the reference limits for two methods was compared. Results:The skewness coefficients of ALP(male, female18-59), ALT, AST, hsCRP, DBil, GGT, Lp (a), TBA, TBil, TG, Glu, HDL-C(male) and CysC, GA, UR in the elderly group deviated from 0, and their kurtosis coefficients also deviated from 3. For these biochemical analytes, the point estimates of the RIs established by the two methods differed greatly and the 90% CIs did not overlap. The analytes with good normality were Alb, ApoA1, ApoB, Ca, ChE, Cl, Cr(E), CysC(18-59), FFA, GA(18-59), HDL-C(female), K, LDL-C, Na, P, PA, SOD, TC, TCO 2, TP and UR. The consistency is good. Except for Ca, 90% CIs of reference limits for some analyte between the two methods coincide with each other. Conclusions:The consistency of different indirect methods is affected by the normality of data.
8.The performance evaluation of four Lp-PLA2 activity assays
Danchen WANG ; Li'an HOU ; Ling QIU ; Xiuzhi GUO ; Liangyu XIA ; Qiong WU ; Yi'cong YIN ; Honglei LI ; Dandan LI ; Qian LIU ; Xuehui GAO ; Liyan LIN
Chinese Journal of Laboratory Medicine 2018;41(3):208-213
Objective To evaluate the analytical performance of four lipoprotein associated phospholipase A2(Lp-PLA2)activity reagents on Beckman AU5800 automatic biochemical analyzer. Methods The remaining serum samples of 214 patients and 140 apparently healthy individuals were collected from March to July 2017 in Peking Union Medical College Hospital.These samples were used for method comparison and reference interval evaluation.According to the guidelines of EP15-A,EP6-A,EP-17 and EP7-P from Clinical and Laboratory Standards Institute(CLSI)standards,the precision, linearity, sensitivity and common interferences(e.g free bilirubin, conjunct bilirubin, hemoglobin and chyle)were assessed.According to EP9-A2,method comparisons of differents regents(Evermed,DiaSys,Hengxiao and Zhongyuan were labeled as A,B,C and D,respectively)were conducted and the differences were estimated at medical decision levels(328U/L,391U/L and 485U/L).Results The precision of four reagents were acceptable.The repeatability(CV%)of A to D were 0.5%-1.7%, 0.7%-3.0%, 0.9%-2.0% and 0.5%-3.3%,respectively.The reproducibility(CV%)were 0.7%-2.9%, 1.4%-3.2%, 1.3%-1.9%and 0.8%-4.1%,respectively.Both of those achievedlaboratory defined quality objective(<5%).The linearity of A to D were 44 -1 992 U/L,39 -1 798 U/L,13 -540 U/L and 75-1 717U/L,respectively.The regression coefficient R2 was between 0.997 and 1.000, and the correlation coefficient(r)was between 0.998 and 1.000.The interference of chyle were acceptable among these four reagents andmet the manufacturer′s requirementsor clinical needs.In a low level of Lp-PLA2,bilirubin had an obvious interferenceonreagent C;B and C were negatively affected when the hemoglobin was 4.5 g/L; and D was positively affected when the hemoglobin was 2.45 g/L.The regression coefficients R2 of A,C,D compared with B were between 0.978 and 0.995,and the correlation coefficients(r)were between 0.989 and 0.998. The expected differences at medical decision levels ranged from -240 U/L to 113 U/L.For A to D,the Lp-PLA2 activity results of 131(93.6%), 140(100%), 82(58.6%), and 128(91.4%)cases were analysed within the manufacturer′s claimed reference intervals.Conclusion The precision and linearity of the four Lp-PLA2 activity detection reagents used in automatic biochemical analyzer are good, but the anti-interference ability needs to be improved.
9.The effect of hemolysis on 41 chemistry and immunology tests and determination of hemolysis alert index
Liangyu XIA ; Ermu XU ; Xince CAO ; Li LIU ; Qian LIU ; Xinqi CHENG ; Yingying HU ; Lin ZHANG ; Ling QIU
Chinese Journal of Laboratory Medicine 2017;40(12):947-952
Objective To evaluate hemolyticinfluence on 41 chemistry and immunology tests and define the hemolysis alert index, which can be used as evidence for sample rejection and test report verification.Methods Method evaluation.As a pair, both hemolyzed and non-hemolyzed serum samples were collected from the same patient at the same time.Hemolysis index and 41 tests were analyzed.The effect of hemolysis in different hemolysis level was evaluated by comparing results of the paired samples.The alertindex were defined by senior laboratory techniciansand clinical professionals based on discussion of widely accepted quality requirements.Results The number of sample with hemolysis index of 1,2,3 and 4was 24, 17, 7 and 4 respectively.Of the 41 analytes, 6 analytes increased in hemolyzed samples comparing to non-hemolyzed samples, namelyaspartate aminotransferase(AST), creatine kinase(CK), potassium(K),lactate dehydrogenase(LD),inorganic phosphorus(iP)and total bilirubin(TBil).Another 9 analytesdecreased in hemolyzed samples comparing to non-hemolyzed samples.These analytes are alkaline phosphatase(ALP), chloride(Cl), creatinine(Cr), immunoglobin M(IgM), sodium(Na), prealbumin (PA),rheumatoid factor(RF),triglyceride(TG),uric acid(UA).Hemolysis alert index was defined as 1 for AST,K,Na and LD;2 for Cr;3 for CK,iP,PA and TBil; and 4 for the other 32 tests.Conclusions Hemolysisalertindex were defined based on the investigation of hemolyticinfluence on 41 chemistry and immunology tests in ourlaboratory.However, hemolytic influence on clinical laboratory tests are closely related to the assay systems.So clinical laboratory should evaluate the hemolytic influence on its own analysis system,and define assay specific hemolysis alert index.
10.Screwdriver aspiration during implant surgery: case report and literature review
WU Lin ; KONG Fanzhi ; QIAN Liangyu ; QIU Chenguang ; SUN Hongtao ; SHE Peng
Journal of Prevention and Treatment for Stomatological Diseases 2022;30(8):582-587
Objective :
To discuss and summarize the preventive measures and treatment methods for aspiration/ingestion during dental procedures.
Methods :
One case of aspiration during an implant operation was reported, and the literature on aspiration/ingestion during oral procedures was reviewed.
Results:
An implant screwdriver accidentally slipped into the mouth of the patient during implant surgery. The patient experienced no obvious discomfort except a few coughs. The surgeon and assistant paused the procedure immediately to search for the screwdriver, but it was not found. The patient declared that there was no special abnormality, such as breathing disorder or chest distress, so we considered that the foreign body was ingestion. After the implant surgery was completed, no foreign body was found in the stomach via gastroscopy. Chest X-ray and CT showed a dense metal shadow in the lower lobe of the left lung. Under local anesthesia, bronchoscopy and biopsy forceps were used by respiratory physicians to clip out the foreign body. After removal of the foreign body, the patient had no obvious discomfort but a slight cough. Cephalexin and metronidazole were given for three days to prevent infection. Three days later, the patient had no complaints of respiratory discomfort. After reviewing the literature, we found that the operation should be paused immediately after aspiration/ingestion occurs during dental procedures and that the dental chair should be laid down to prevent the foreign body from descending deeper, which may increase the difficulty of removal and cause gastrointestinal and respiratory tract injury. The position of the foreign body should be determined by imaging examination, and the corresponding means to remove the foreign body should be performed.
Conclusion
Patients may have no obvious symptoms after aspiration/ingestion during dental procedures, and the foreign body can be removed after imaging examination.