1.The diagnostic value of dual source coronary CT angiography combined with dynamic CT myocardial perfusion imaging in coronary artery disease
Jie WANG ; Hongwei CHEN ; Xiangming FANG ; Pingyan QIAN
Chinese Journal of Radiology 2017;51(4):251-256
Objective To evaluate the diagnostic value of one-stop cardiac CT (stress dynamic CT-MPI combining with CTA) in CAD. Methods Thirty patients underwent CCTA combined with stress dynamic CT-MPI and stress SPECT-MPI including 16 patients underwent ICA were retrospectively enrolled. All procedures were performed within 2 weeks without related treatment. CT-MPI and SPECT-MPI were evaluated visually and MBF was quantified according to dynamic CT-MPI which was compared through paired t test. The diagnostic value of CT-MPI for myocardial ischemia was evaluated with SPECT-MPI as the reference standard. The consistency between the two techniques was determined by Kappa test. With SPECT combined with ICA as the reference standard, we evaluated the value of CT-MPI and its combination with CCTA in the diagnosis of CAD with hemodynamic stenosis. Results On stress CT-MPI, 19 of 30 patients and 52 segments were evaluated with myocardial perfusion defects. There was a significant difference in MBF values between normal[(117.61±29.82)ml·100 ml-1·min-1] and hypoperfused [(80.60±22.15)ml·100 ml - 1 · min - 1] segments (t=15.764,P<0.001). With SPECT as reference standard, the sensitivity, specificity were 94.12% (32/34), 95.80% (456/476) on the vessel basis. The Kappa value of the two examinations was 0.772(P<0.001). As for the 16 patients who also underwent ICA, 15 patients with 22 vessel-areas had hemodynamic stenosis on CT-MPI. Compared with SPECT combined with ICA, the sensitivity, specificity for detecting hemodynamic stenosis were 92.31% (12/13), 71.43% (25/35) for CT-MPI;100%(13/13), 51.43%(18/35) for CTA and 92.31%(12/13), 82.86%(29/35) for CT-MPI combined with CTA, respectively. Moderate correlation was observed between the combination of CT-MPI and CCTA and reference standard (r=0.690,P<0.001). Conclusion Stress dynamic CT-MPI can detect myocardial perfusion defects and hemodynamic changes and improves the diagnostic ability of functional stenosis of CAD combined with CTA, which can finally achieve the one-stop mode of cardiac CT in CAD.
2.A randomized controlled trial for the efficacy and safety of REXEEDTM series highflux dialyzer
Weiming ZHANG ; Jiaqi QIAN ; Nan CHEN ; Bingshun WANG ; Pingyan SHEN ; Yongmei WANG ; Wen ZHANG ; Yucheng YAN ; Ping ZHU
Chinese Journal of Nephrology 2009;25(8):601-606
Objective To evaluate the efficacy and safety of REXEEDTM series highflux dialyzer. Methods A randomized cross-over study of 3×3 Latin square was designed based on the surface area of dialyzer membrane (1.5 m2 and 2.1 m2). Seventy-two stable maintenance hemodialysis (MHD) patients from Shanghai Renji Hospital and Ruijin Hospital were enrolled in this study for 3 consecutive weeks. REXEEDTM-15AC, 15UC, 21AC, 21UC dialyzers were used as trial group and APS-15U,BIO-HX100 dialyzers were used as control group. The clearances of urea, creatinine, phosphorus and β2-microglobulin were calculated. Adverse event and adverse reactions were recorded. Results There were significantly higher urea and creatinine clearance in 1SAC and 15UC dialyzers as compared to APS-15U dialyzer [(222.07±18.74) mi/min, (220.23±26.26) ml/min vs (199.56±14.21) ml/min; (176.73±16.41) ml/min, (175.22±25.94) ml/min vs (165.42±14.68) ml/min, all P<0.05]. There were significantly higher urea, creatinine and β2-microglobulin clearance in 21AC and 21UC dialyzer as compared to BIO-HX100 dialyzer [(230.59±15.24) ml/min, (233.96±7.06) ml/min vs (203.43±36.66) ml/min; (183.50±25.90) ml/min, (181.05±23.94) ml/min vs (166.25±29.82) ml/min; (111.77±53.42) ml/min, (125.54±51.99) ml/min vs (42.39±4.81) ml/min; all P<0.05]. There was no significant difference of phosphorus clearance between REXEEDTM series dialyzers and control dialyzers. The efficiency of urea clearance and urea reduction ratio could achieve clinical targets in REXEEDTM series. Conclusion REXEEDTM series highflux dialyzers are effective and safe for clinical application.