2.Location of hUART1 in proximal tubular epithelial cell by cloning the hUART1 gene and preparing the polyclonal antibody
Di WU ; Ping ZHANG ; Xiangmei CHEN
Medical Journal of Chinese People's Liberation Army 1983;0(05):-
Objective To prepare the anti-hUART1 polyclonal antibody and investigate the subcellular localization of hURAT1 protein. Methods The full-length hURAT1 gene was obtained by RT-PCR and inserted into the fusion expression vector pEGFP-N3,the predicated antigen epitope was cloned into GST fusion protein expression plasmid pGEX-5X-1, transformed into E. coli BL21 cells for expressing recombinant GST-hURAT1 protein induced by IPTG. The purified hURAT1-GST fusion protein was employed to immunize rabbit for preparing the polyclonal antibody. The expression of hURAT1 was analyzed by western-blot and immunohistochemistry in human kidney. pEGFP-hURAT1 was transfected into the LLC-PK1 cell in order to observe the subcellular localization of the gene using confocal microscopy. Results Specific anti-hURAT1 rabbit polyclonal antibody was obtained, and both Western-blot and immunohistochemistry showed that hURAT1 was expressed in the human kidney brush border,localized in the apical membrane of the LLC-PK1 cell. Conclusions hURAT1 protein was a membrane protein located in renal proximal tubule, which could be detected in the apical membrane. The anti-hURAT1 polyclonal antibody could be used for studying the physiological function of hURAT1 and its pathology.
3.The change of nuclear factor ?B activity in peripheral blood monocytes in patients with acute coronary syndrome
Ping SHU ; Di LIU ; Huiyun ZHOU
Chinese Journal of Emergency Medicine 2006;0(01):-
Objective To investigate the role of nuclear factor ?B activation in the onset of acute coronary syndrome(ACS).Methods 76 patients with acute myocardial infraction(AMI),41 patients with unstable angina pectoris(UAP),43 patients with stable angina pectoris(SAP)and 20 normal controls were enrolled.NF-?B activation in monocytes in peripheral blood monocyte was determined by ELISA with the NF-?B p65 Kit the at 3 and 5 days after admission.Results The activity of NF-?B in monocytes of peripheral blood in AMI patients and UAP patients was significantly higher than that in SAP patients and normal controls(P
7.Anti-apoptosis Mechanism of Serum Containing Xin Mai Tong Decoction in Myocardial Cell Under Oxidative Stress
Traditional Chinese Drug Research & Clinical Pharmacology 1993;0(04):-
Objective To explore the anti-apoptosis mechanism of serum containing Xin Mai Tong decoction in myocardial cell under oxidative stress.Methods The neonate rat myocardial cell was cultivated and the model of myocardial cell apoptosis was induced with 400 ? mol/L H2O2.The cell viability was determined by MTT method,myocardial cell apoptosis was determined by TUNEL method,and the intra-cellular expression of HSP70,NF-? B and caspase-3 in myocardial cell was determined by immunocytochemistry.Results Administration of 400 ? mol/L H2O2 for 1 hour was harmless to myocardial cell,the expression of HSP70 being slightly increased.However,apoptosis was induced in myocardial cells at the 6 th hour after 400? mol/L H2O2 administration.The serum containing Xin Mai Tong significantly attenuated the decrease of cell viability and apoptosis which was induced by oxidative stress.Increased expression of HSP70 was induced by the serum containing Xin Mai Tong,and the activation of NF-? B and caspase-3 were significantly inhibited.Conclution The serum containing Xin Mai Tong decoction shows a significant inhibitory effect on apoptosis induced by H2O2,and the mechanism may be through increasing protein expression of HSP70,inhibiting the activation of NF-? B and decreasing the expression of caspase-3.
8.Effect of disinfectant with benzethon chloramine and isopropanol as main active ingredients on the accuracy of dental impression.
Di XU ; Dong Hao WEI ; Ya Chi ZHANG ; Ping DI ; Ye LIN
Journal of Peking University(Health Sciences) 2020;52(6):1112-1116
OBJECTIVE:
To assess the effect of disinfectant (Cavicide) with benzethon chloramine and isopropanol as main active ingredients disinfectant on dental impression accuracy.
METHODS:
The effect of Cavicide on three impression materials (alginate, polyether and vinylpolysiloxane) were assessed using a standard model. The standard model was digitized by an extraoral scanner (IScan D103i, Imetric). For each kind of impression materials, thirty impressions were taken following the manufactures' instruction in the same conditions. Subsequently, the impressions were randomly divided into three groups, with ten impressions in each group. After the impression taking was completed, the three groups underwent pure water rinse for 1 min (blank control, BC), 2% glutaraldehyde solution immersion disinfection for 30 min (glutaraldehyde, GD), and Cavicide solution spray disinfection for 5 min (Cavicide, CC), respectively. All the impressions were digitized by the extraoral scanner (IScan D103i, Imetric) after disinfection and exported to a dedicated three-dimensional analysis software (Geomagic Qualify 2014, Geomagic, USA). In the software, the digital models of the impressions were trimmed to teeth and then superimposed with the digitized standard model via best-fit alignment. Root mean square (RMS) was used to evaluate the deviations between the impression and the standard model. The deviation in the anterior and posterior regions was evaluated respectively. One-way ANOVA test and the LSD post-hoc test were used to compare the deviations between the three groups (P < 0.05). The color map of each superimposition was saved for visual analysis.
RESULTS:
For the polyether and vinylpolysiloxane materials, the difference between the three groups was not statistically significant (P=0.933, P=0.827). For the alginate material, the difference in posterior region between group GD and group BC, as well as group GD and group CC were statistically significant (GD vs. BC, P=0.001; GD vs. CC, P=0.002), while the difference between group BC and group CC was not statistically significant (P=0.854). The visual analysis showed an obvious deviation in the buccal-lingual direction in group GD.
CONCLUSION
Disinfectant (Cavicide) with benzethon chloramine and isopropanol as main active ingredients using spray disinfection has no effect on the accuracy of the alginate, polyether and vinylpolysiloxane impressions.
2-Propanol
;
Chloramines
;
Dental Impression Materials
;
Dental Impression Technique
;
Disinfectants
;
Disinfection
;
Models, Dental
9.Study on Pharmacokinetics of Capecitabine/Polyethylene Glycol 1000/Montmorillonite Compound in Rats in vivo
Lingyu KONG ; Ping YANG ; Di HAO ; Qian WANG
China Pharmacy 2015;(19):2641-2643
OBJECTIVE:To establish a method of determining the plasma concentration of capecitabine/polyethylene glycol 1000/montmorillonite (CAP/PEG1000/MMT) in rats’plasma for the study on pharmacokinetics of CAP compound in rats in vivo. METHODS:HPLC was adopted. The determination was performed on Kromasil C18 with mobile phase consisted of 0.1% glacial acetic acid-acetonitrile(73∶27),at the flow rate of 1.0 ml/min. The detection wavelength was 250 nm and column temperature was 40 ℃. The sample size was 10 μl. 18 Wistar rats were randomly divided into CAP group,CAP/MMT group(MMT as carrier)and CAP/PEG1000/MMT group(PEG1000/MMT as carrier)and ig given corresponding drugs,that equal to 200 mg/kg of CAP. Blood sample was respectively taken 15,30,60,90,120,180,240,300 and 360 min after the administration of drugs,and plasma was isolated and added with internal standard ferulic acid. The concentration of the drug in the plasma was determined by HPLC fol-lowing protein precipitation with methanol,based on which the pharmacokinetic parameters were calculated by 3p97 software. RE-SULTS:The linear range of CAP was 0.054 9-4.390 0 μg/ml (r=0.998 2) with the method recovery of 98.2%-102.1%(RSD=1.50%-3.29%, n=5) and absolute recovery of 76.2%-78.9%(RSD=2.29%-2.99%, n=5). In the above-mentioned three groups,t1/2 were(1.11±0.32),(1.57±0.32)and(1.62±0.10)h;cmax were(2.91±0.36),(0.91±0.23)and(0.91±0.14)μg/ml;AUC0-6 h were (8.70 ± 1.79),(3.76 ± 0.27) and (3.73 ± 0.25)μg·h/ml;and tmax were (0.97 ± 0.20),(1.55 ± 0.47) and (1.50 ± 0.07) h,respectively. There was no significant difference in the pharmacokinetic parameters between the CAP/MMT group and CAP/PEG1000/MMT group(P>0.05). CONCLUSIONS:The method is reliable and simple,and can be used for pharmacokinetic study of CAP/PEG1000/MMT in rats. MMT and PEG1000/MMT compound can prolong CAP acting time in the body.
10.Evaluation of alveolar ridge reconstruction and esthetic result following immediate implant
Ying WANG ; Ye LIN ; Bo CHEN ; Yu ZHANG ; Ping DI
Journal of Peking University(Health Sciences) 2016;48(1):121-125
Objective:To evaluate the bone alteration subject to remodeling and analyze the esthetic result following immediate implant placement of incisors.Methods:In this study,20 patients (1 3 women,7 men)were involved,who needed implants for incisors of maxilla.The patients received 23 im-mediate implants totally.On the day of surgery and 6 months after the implants were placed,Cone beam CT (CBCT)was taken.The thickness of the alveolar ridge and the vertical change of marginal bone levels onthe mesial and distal aspects of theimplants were measured using the computer software (Planme-caRomexis Viewer 3.6.0.R).The evaluation of esthetic result by labial convexity score (LCS)and pa-pilla index score (PIS)were analyzed pre-operation and one year after the final crown was delivered.The statistics with paired-t test for the measurement data and Willcoxon test for rating data were done by SPSS 20.0.Results:The survival rate in the two-year follow-up was 1 00%.The measuring point 1 (MP1 ), MP2,MP3 and MP4 (0,2,4,6 mm apical to the implant platform,respectively)got significant altera-tions after 6 months of the follow-up.These differences were statistically significant (P<0.05 ).The major alteration happened at MP1 and MP4,which got (-0.89 ±2.06)mm and (-0.75 ±1 .28)mm reduction of the alveolar,respectively.The marginal alveolar ridge resorption was (-0.42 ±1 .24)mm and(-0.91 ±1 .96)mm for Ankylos System and Replace System,respectively,and the difference was not statistical significant .The esthetic results were quite acceptable.Before treatment,1 8 incisors rated 3 for LCS,and 2 incisors rated 4 for LCS;after final restoration,only 5 incisors rated 3 for LCS,and 1 4 incisors rated 2 for LCS.Before treatment,1 5 incisors rated 3 for PIS;after final restoration,1 3 incisors rated 3 for PIS.There was no statistically significant difference for the PIS pre-operation and 1 year after final restoration,while there was statistically significant negative change for LCS.Conclusion:Even fol-lowing the proper surgical technique,the alveolar ridge wall still can’t be maintained after immediate im-plant placed in fresh socket of incisors.The inter-dental papilla could be well maintained,while due to the remodeling of labial bone,labial convexity will inevitably collapse.Therefore immediate implant still has esthetic risk.