1.Environmental sampling for SARS-CoV-2 at a reference laboratory and provincial hospital in central Viet Nam, 2020
Thá ; i Hù ; ng Đỗ ; Văn Thà ; nh Nguyễn ; Thế Hù ; ng Đinh ; Xuâ ; n Huy Lê ; ; Quang Chiê ; u Nguyễn ; Văn Quâ ; n Lê ; ; Bảo Triệu Nguyễn ; Ngọc Bí ; ch Ngâ ; n Nguyễn ; Thị Ngọc Phú ; c Nguyễn ; Kim Mai Huỳnh ; Hoà ; ng Long Trịnh ; Thị Kim Trang Lê ; ; Thù ; y Dung Diệp ; Thủy Thị Thu Đỗ ; Hiền Thị Thu Bù ; i ; Alyssa M Finlay ; Quốc Việt Nguyễn ; Philip L Gould
Western Pacific Surveillance and Response 2021;12(3):47-55
Objective: To determine whether environmental surface contamination with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) occurred at a provincial hospital in Viet Nam that admitted patients with novel coronavirus disease 2019 (COVID-19) and at the regional reference laboratory responsible for confirmatory testing for SARS-CoV-2 in 2020.
Methods: Environmental samples were collected from patient and staff areas at the hospital and various operational and staff areas at the laboratory. Specimens from frequently touched surfaces in all rooms were collected using a moistened swab rubbed over a 25 cm2 area for each surface. The swabs were immediately transported to the laboratory for testing by real-time reverse transcription polymerase chain reaction (RT-PCR). Throat specimens were collected from staff at both locations and were also tested for SARS-CoV-2 using real-time RT-PCR.
Results: During the sampling period, the laboratory tested 6607 respiratory specimens for SARS-CoV-2 from patients within the region, and the hospital admitted 9 COVID-19 cases. Regular cleaning was conducted at both sites in accordance with infection prevention and control (IPC) practices. All 750 environmental samples (300 laboratory and 450 hospital) and 30 staff specimens were negative for SARS-CoV-2.
Discussion: IPC measures at the facilities may have contributed to the negative results from the environmental samples. Other possible explanations include sampling late in a patient’s hospital stay when virus load was lower, having insufficient contact time with a surface or using insufficiently moist collection swabs. Further environmental sampling studies of SARS-CoV-2 should consider including testing for the environmental presence of viruses within laboratory settings, targeting the collection of samples to early in the course of a patient’s illness and including sampling of confirmed positive control surfaces, while maintaining appropriate biosafety measures.
2.Systematic sequencing of imported cases leads to detection of SARS-CoV-2 B.1.1.529 (Omicron) variant in central Viet Nam
Do Thai Hung ; Nguyen Bao Trieu ; Do Thi Thu Thuy ; Allison Olmsted ; Trinh Hoang Long ; Nguyen Duc Duy ; Huynh Kim Mai ; Bui Thi Thu Hien ; Nguyen Van Van ; Tran Van Kiem ; Vo Thi Thuy Trang ; Nguyen Truong Duy ; Ton That Thanh ; Huynh Van Dong ; Philip L Gould ; Matthew R Moore
Western Pacific Surveillance and Response 2022;13(4):82-85
As authorities braced for the arrival of the Omicron variant of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), infrastructure investments and government directives prompted action in central Viet Nam to establish capacity for genomic surveillance sequencing. From 17 November 2021 to 7 January 2022, the Pasteur Institute in Nha Trang sequenced 162 specimens from 98 150 confirmed SARS-CoV-2 cases in the region collected from 8 November to 31 December 2021. Of these, all 127 domestic cases were identified as the B.1.617.2 (Delta) variant, whereas 92% (32/35) of imported cases were identified as the B.1.1.529 (Omicron) variant, all among international flight passengers. Patients were successfully isolated, enabling health-care workers to prepare for additional cases. Most (78%) of the 32 Omicron cases were fully vaccinated, suggesting continued importance of public health and social measures to control the spread of new variants.