1.Differences in percussion-type measurements of implant stability according to height of healing abutments and measurement angle.
Yang Hoon PARK ; Richard LEESUNGBOK ; Suk Won LEE ; Janghyun PAEK ; Jeong Yol LEE
The Journal of Korean Academy of Prosthodontics 2018;56(4):278-286
PURPOSE: The purpose of this study was to evaluate the effect of healing abutment height and measurement angle on implant stability when using Periotest and AnyCheck. MATERIALS AND METHODS: 60 implants were placed into artificial bone blocks. After implant insertion, 2, 3, 4 and 5 mm healing abutments were installed on 15 specimens, respectively. Insertion torque value, implant stability test, Periotest value were measured. Insertion torque value was controlled between 45 – 55 Ncm. AnyCheck was used for measuring implant stability test and Periotest M was used for measuring Periotest value. Implant stability test and Periotest value were measured at the angles of 0 and 30 degrees to the horizontal plane. Measured values were analyzed statistically. RESULTS: Insertion torque value had no significant difference among groups. When healing abutment height was higher, implant stability test and Periotest value showed lower stability. Also when measurement angle was decreased, implant stability test and Periotest value showed lower stability. CONCLUSION: When measuring stability of implants with percussion type devices, measured values should be evaluated considering height of healing abutments and measurement angle.
Percussion
;
Torque
2.The development of physical diagnosis: Historical perspectives.
Journal of Medicine University of Santo Tomas 2022;6(S1):25-31
The history of physical diagnosis started with Hippocrates and his school. History taking, inspection, palpation, and sometimes immediate auscultation and examination of the urine are fundamental diagnostic tools. The Hippocratic Corpus and Galen’s authoritative theoretical writings dominate medical thinking for over 1000 years. Clinical examination advances through Vesalius and Morgagni’s discoveries of human dissection (1543) and pathologic anatomy (1761) respectively. The Vienna school through Auenbrugger introduces percussion in 1760. The Paris school formally establishes physical diagnosis with the invention of the stethoscope by Laennec in 1816.
Medical History Taking
;
Percussion
3.The Effect of Chest Physiotherapy on the Amount of Tracheal Secretion and PaO2.
Journal of Korean Academy of Fundamental Nursing 2000;7(3):355-365
The purpose of this research was to find out the effect of chest physiotherapy on the amount of tracheal secretion and PaO2. After changing position of the neurosurgical patients who had tracheostomy cannula, experimental treatments were applied as bellows, manual chest percussion on group I, chest percussion and manual chest vibration on group II, chest percussion and mechanical chest vibration on group III were done. After these trials, we have analyzed the efficacy of each procedures comparing the group differences in the quantity of tracheal secretion and PaO2. Target samples were sixty patients aged between 20 to 60 who have tracheostomy state and decreased consciousness status that were admitted in NICU of a university hospital from June 1 to August 31, 1999. They assigned randomly into three experimental groups. To compare the effect of each interventions, tracheal secretion quantity was measured and PaO2 was analyzed via arterial blood gas analyzer. The data were analyzed by ANCOVA of 5% significance level using SPSS P/C program. The results were as bellows. 1) The first hypothesis " There is a difference in the quantity of the secretion among Group I, Group II and Group III" was accepted.(F=29.27, p=0.00) 2) The second hypothesis "There is a difference in PaO2 among Group I, Group II and Group III" was rejected.(F=1.71,p=0.19) From this study results, positional change and manual chest vibration including chest percussion were the most effective treatment to get maximum amount of tracheal secretion and it was confirmed that mechanical chest vibration also made much better effect than sole chest percussion method. Therefore, we concluded that the mechanical or manual chest vibration with chest percussion is more effective respiratory care method than the sole chest percussion.
Catheters
;
Consciousness
;
Humans
;
Percussion
;
Thorax*
;
Tracheostomy
;
Vibration
4.A study on the measurement of the implant stability using resonance frequency analysis.
Cheol PARK ; Ju Hwan LIM ; In Ho CHO ; Heon Song LIM
The Journal of Korean Academy of Prosthodontics 2003;41(2):182-206
STATEMENT OF PROBLEM: Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. PURPOSE: Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the Periotest., Dental Fine Tester. and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. MATERIAL AND METHOD: To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used: 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. RESULTS: Results from these studies were such as follows: The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the Periotest.. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the Periotest. value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). CONCLUSION: The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices. It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.
Humans
;
Osseointegration
;
Percussion
;
Rabbits
;
Radiography
;
Ribs
;
Tibia
;
Transducers
5.Therapeutic Efficacy and Prognostic Factors of Canalith Repositioning Maneuver in the Patients with Benign Paroxysmal Positional Vertigo.
Shi Nae PARK ; Kyoung Ho PARK ; Ji Hong KIM ; Jong Hoon KIM ; Bong Jin CHOI ; Ji Hyeon SHIN ; Min Ah HAN ; Sang Won YEO
Journal of the Korean Balance Society 2007;6(1):9-15
BACKGROUND AND OBJECTIVES: The purpose of this study were to evaluate the therapeutic efficacy of canalith repositioning maneuver (CRP) according to accompanying mastoid percussion and to investigate the prognostic factors that may affect successful repositioning maneuver and the recurrence of benign paroxysmal positional vertigo. MATERIALS AND METHOD: A total of 70 patients with canalith type BPPV visiting the dizziness clinic of Kangnam St. Mary's Hospital were included in this study. Variables identified for statistical analysis were patient's age, sex, maneuver method, number of involved canal, number of CRP and dizziness handicap inventory. RESULT: Overall success rate of CRP was 90%. The mean number of maneuver was 1.6 and the recurrence rate was 25.7% during the follow up period. Success rate of CRP (94.9%) was higher than maneuver without mastoid percussion (83.9%) though it was not statistically significant. Successful CRP group showed the significant less number of maneuvers at initial treatment session and less number of involved canal than failed CRP group at the time of one week-follow up visit. Patients with recurrence of BPPV had the more number of CRP during the period of previous BPPV. CONCLUSION: Therapeutic efficacy of CRP with mastoid percussion was higher than CRP without mastoid percussion though it was not statistically significant. Suggesting prognostic factors for effective CRP and recurrence were number of CRP and number of involved canal.
Dizziness
;
Follow-Up Studies
;
Humans
;
Mastoid
;
Percussion
;
Prognosis
;
Recurrence
;
Vertigo*
6.Animal Models of Traumatic Brain Injury.
Brain & Neurorehabilitation 2011;4(1):12-20
Traumatic brain injury could be used to describe all injuries to the brain caused by external mechanical forces. It shows a variety of clinical manifestations from mild to severe forms and can result to death. Moderate to severe injuries can produce disabilities on physical, cognitive, behavioral, and emotional aspects. Animal models of traumatic brain injury have been developed to reproduce characteristics of human brain injury, to understand molecular and cellular pathophysiology and neurobehavioral outcomes following trauma and to find out the promising pharmacological drugs or rehabilitative skills to treat. This article reviewed the current experimental traumatic brain injury models, including weight drop, fluid percussion, and controlled cortical impact, and also the neurobehavioral assessments that are most commonly used to measure loss of function.
Animals
;
Brain
;
Brain Injuries
;
Humans
;
Models, Animal
;
Percussion
7.Quantitative Analysis of Patellar Tendon Reflexes with Newly Designed Percussion Instrument.
Young Min KO ; Chul KIM ; In Sun PARK ; Sang Hee NAM
Journal of the Korean Academy of Rehabilitation Medicine 1999;23(3):572-580
OBJECTIVE: There has been some existing problems with the electrical reflex hammer. The occurrence of pressure build up with percussion and change of hammering points is one example. In order to make improvements on this device, we conducted studies with a newly designed percussion instrumental stimulator. METHOD: The data collected from the first group was based on the manual percussion of electrical reflex hammer on the patella ligament. The data collected from the second group by usage of a newly designed instrumental stimulator maintained steady pressure and time and target position on the electrical reflex hammer. Comparisons were made between the two group. RESULTS: Our single measure of latency and amplitude on the manual and instrumental percussion group resulted in the reliability of 84.67%, 91.23%, 73.63%, and 83.29%. The 10 repeated measure of latency and amplitude on the manual and instrumental percussion group resulted in the reliability of 99.95%, 99.97%, 99.90%, and 99.94%. CONCLUSION: From our experiment on the tendon reflex, we found out that it is important to have an instrumental stimulator that can maintain steady pressure while it is applying percussion to accurate data. On manual percussion, it is important to obtain data based on mean value of repeated measurements.
Ligaments
;
Patella
;
Patellar Ligament*
;
Percussion*
;
Reflex*
;
Reflex, Stretch
8.Effects of Intrapulmonary Percussive Ventilation in Patients with Excess or Retained Airway Secretions.
Kyoung Min LEE ; Kwang Ho LEE ; Dae Ja UM
Korean Journal of Anesthesiology 1993;26(6):1242-1246
Intrapulmonary percussive ventilation(IPV), developed by Forrest M. Bird, M.D., delivers high flow mini-bursts of air along with bronchodilator to the lung at a rate of more than 200 times per minute and has the theoretical potential for aiding in expectoration of secretions through internal percussion. To evaluate effects of IPV on respiratory therapy, we compared IPV with conventional chest physical therapy in patients with excess or retained pulmonary secretions. The results are follows. 1) There were no significant differences among the experimental group with respect to blood pressure, heart rate and respiratory rate. 2) Arterial oxygen tension was significantly increased after IPV. 3) ICU stay was slightly shortened in the experimental group as compared with that in the control group. However, there was no statistical significance. These results indicate that IPV may be effective in respiratory care of patients with excess or retained airway secretions.
Birds
;
Blood Pressure
;
Heart Rate
;
Humans
;
Lung
;
Oxygen
;
Percussion
;
Respiratory Rate
;
Respiratory Therapy
;
Thorax
;
Ventilation*
9.Prognosis and evaluation of tooth damage caused by implant fixtures.
Wook Jae YOON ; Su Gwan KIM ; Mi Ae JEONG ; Ji Su OH ; Jae Seek YOU
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2013;39(3):144-147
Damage to adjacent teeth is one of the various complications that may occur during implant placement and is often the result of improper direction during fixture placement or excessive depth of placement. In general, if detrimental symptoms, such as reaction to percussion in damaged teeth, mobility, and pulp necrosis, are not present, osseointegration should be observed at follow-up. In three cases, the possibility of root damage due to an implant fixture placed too close to each adjacent tooth was perceived on radiographs. However, in all of these cases, there were no clinical symptoms or radiographic changes present in the tooth, and the implants did not exhibit decreased stability or peri-implantitis. Therefore, we can carefully predict that the implant fixture close to the adjacent tooth did not invade the cementum of the root, and therefore did not produce the suspected pulpal damage or periradicular symptoms. In this study, we considered both the implant status as well as the adjacent tooth.
Dental Cementum
;
Dental Implants
;
Dental Pulp Necrosis
;
Follow-Up Studies
;
Osseointegration
;
Percussion
;
Peri-Implantitis
;
Prognosis
;
Tooth
10.Prognostic Factors of Percutaneous Radiofrequency Neurotomy on the Posterior Primary Ramus.
Hoon JOY ; Sung Kon HA ; Se Hoon KIM ; Dong Jun LIM ; Jung Yul PARK ; Jung Keun SUH
Journal of Korean Neurosurgical Society 2003;33(1):51-55
OBJECTIVE: We report our experience of percutaneous radiofrequency neurotomy(PRN) on the posterior primary ramus with at least two years follow up. METHODS: Two hundred and twenty-eight patients were underwent PRN on the posterior primary ramus for refractory low back pain during last three years. One hundred and twenty-eight patients were met all inclusion criteria indicating facetal originated pain(group II), and 100 patients were not(group I). Radiofrequency procedures were done in usual manner. Pain reliefs were estimated at 1 week, 1 month, 6 months and 2 years using visual analog scale. RESULTS: Positive responders were 56% at 1 week, 46% at 1 month, 18% at 6 months, and 13% at 2 years after PRN in group I, and 78.9% at 1 week, 75.4% at 1 month, 62.5% at 6 months, and 54.7% at 2 years in group II. Prominent local tenderness, percussion tenderness, pain on getting up, extension and transitional movement, radiating pain on buttock and/or posterior thigh, and good immediate response were found to be significantly related to outcome. And age, sex, symptom duration, bilateral symptoms, favorable imaging study results, previous lumbar surgery, and degrees of pain relief from diagnostic block were not. CONCLUSION: Percutaneous radiofrequency neurotomy on the posterior primary ramus has long-term beneficial effect, without any morbidity in our series. And the long-term good results will be anticipated after proper selection among patients with facet joints related low back pain.
Buttocks
;
Follow-Up Studies
;
Humans
;
Low Back Pain
;
Percussion
;
Thigh
;
Visual Analog Scale
;
Zygapophyseal Joint