1.Preparation and quality control of compound quercetin creams
Chuanmei WEI ; Limin HU ; Qizhong FAN ; Shaowei SUN ; Peiming GAO
Chongqing Medicine 2015;(23):3236-3238,3241
Objective To study the preparation of quercetin compound cream and establish its standard of quality control. Methods The composition of recipe and manufacturing technique were designed.The content of components were determined by HPLC,and its stability tests were carried out.Results The product was a kind of yellow smooth cream.The linear ranges were 0.053-1.696 μg for quercetin(r=0.999 9),0.053-1.696 μg for 8-methoxypsoralen(r=0.999 8)and 0.100-1.000 μg for beta-methasone(r=0.999 9).The average recovery rate were 99.83%,99.52%,and 99.74% of quercetin,8-methoxypsoralen,and beta-methasone(n=9).After 12 months′long term stability test,all the 3 batches of sample preparations were in line with relevant regu-lations.Conclusion The designed recipe was reasonable,and the manufacturing technique was feasible,with stable and controllable quality.
2.Expressions and clinical significance of plasma exosomal hsa_circ_0022417 in gastric cancer
Huijie GAO ; Wei GUO ; Xuanhu XIE ; Peipei LU ; Peiming ZHENG
Chinese Journal of General Surgery 2022;37(4):275-278
Objective:To investigate expressions and clinical significance of plasma exosomal hsa_circ_0022417 in gastric cancer (GC).Methods:Sixty gastric cancer patients, 30 chronic gastritis patients (disease control group) and 30 healthy volunteers (healthy control group) were enrolled in this study. The expression levels of plasma exosomal hsa_circ_0022417 and serum CEA and CA19-9 were detected. The ROC curve and AUC were used to estimate the diagnostic capacity.Results:Compared with chronic gastritis patients and healthy control, the expression of plasma exosomal hsa_circ_0022417 was significantly upregulated in the gastric cancer group ( F=9.96, P<0.05). The expression level of hsa_circ_0022417 in GC tissue was significantly higher than that in adjacent tissue ( t=6.08, P<0.05). The AUC of hsa_circ_0022417, serum CEA and CA 19-9 was 0.79, 0.68 and 0.66, respectively. The combined detection of three indicators had the highest AUC (0.86) ( P<0.05). The expression level of exosomal hsa_circ_0022417 was significantly correlated with tumor size ( χ2=6.42, P<0.01), differentiation degree ( χ2=5.83, P=0.05), TNM stage ( χ2=7.14, P<0.05) and lymph node metastasis ( χ2=5.17, P<0.05). Conclusion:Exosome hsa_circ_0022417 is highly expressed in the plasma of GC patients, which is of great significance for clinical auxiliary diagnosis and early screening of GC.
3.Expression and diagnostic value of plasma exosomal hsa_circ_0064910 in gastric cancer
Huijie GAO ; Wei GUO ; Xuanhu XIE ; Peipei LU ; Peiming ZHENG
Chinese Journal of Laboratory Medicine 2022;45(3):246-251
Objective:This study aimed to investigate the expression of plasma exosomal hsa_circ_0064910 in gastric cancer (GC) patients, explore its correlation with the clinical pathological characteristics and evaluate its diagnostic efficacy in GC.Methods:Sixty patients with GC and 30 patients with Chronic Gastritis (disease control group) admitted to The First Affiliated Hospital of Henan University from October 2019 to December 2020 were selected. Meanwhile, 30 healthy subjects (healthy control group) who underwent physical examination were also enrolled. General data of GC patients were collected, including tumor size, degree of differentiation, TNM stage, lymph node metastasis, etc. Blood samples were collected before treatment and the expression levels of plasma exosomal hsa_circ_0064910 were detected via quantitative reverse transcription PCR (qRT-PCR). The serum concentrations of traditional biomarker (CEA and CA19-9) were measured via a chemiluminescent detection system. The receiver operating characteristic (ROC) curve and area under curve (AUC) were used to estimate the diagnostic capacity of different index in GC. Then, the expression difference of plasma exosomal hsa_circ_0064910 in GC patients before and after operation was analyzed, and its relationship with clinicopathological features of GC patients was also investigated.Results:RT-PCR results revealed that compared with Chronic gastritis patients and healthy control, the expression of plasma exosomal hsa_circ_0064910 was upregulated in the gastric cancer group(0.47±0.06, 0.43±0.05, 0.97±0.12, all P<0.001). The area under the ROC curve was 0.778, and AUC of the combination of CEA and CA19-9 for the diagnosis of gastric cancer was 0.841. which was higher than the diagnostic accuracies of CEA (AUC=0.673)and CA 19-9(AUC=0.653). The expression level of exosomal hsa_circ_0064910 was also significantly correlated with tumor size( χ2=7.545, P<0.01), TNM stage( χ2=4.571, P<0.05)and lymph node metastasis( χ2=6.907, P<0.01). The postoperative expression levels of exosomal hsa_circ_0064910 were lower compared with those of preoperative levels(1.21±0.21 vs 0.62±0.11, P<0.01). Conclusion:Our data demonstrated that exosomal hsa_circ_0064910 is highly expressed in GC patients and might be a potential noninvasive biomarker for the auxiliary diagnosis of GC.
4.Construction and application of the module of medical first-aid at the door of the space capsule and the air evacuation after the manned spaceflight lands
Liping DING ; Yong JI ; Jing LI ; Xiaopei GAO ; Tao WANG ; Peiming SUN ; Xiaoming LIU ; Junfeng GAO ; Xiaoyong SONG
Chinese Journal of Emergency Medicine 2023;32(5):627-631
Objective:To explore the module of the construction and application of medical first-aid at the door of the space capsule and the air evacuation.Methods:According to the purpose, principle, and method set by the module, it was divided into two sub-modules: medical first-aid at the door of the space capsule and the air evacuation. During the comprehensive first-aid training, independent training and combined training were carried out respectively according to different mission stages of launch and recovery and different recovery terrain. Meanwhile, research was performed to ensure that medical carrying equipment was lightweight, modular, and portable, and the efficiency of modularization construction was tested in the comprehensive training.Results:The module of medical first-aid at the door of the space capsule and the air evacuation obviously shortened the rescuing time during the comprehensive training, the saving effect was remarkable, and the overall saving efficiency was significantly improved.Conclusions:The module of medical first-aid at the door of the space capsule and the air evacuation meet the requirements that the emergency support system of aerospace medicine should function on an immediate basis, ensuring accurate treatment and air evacuation without any delay, so that to achieve the aim of aerospace medicare.
5.Application of scenario simulation teaching combined with modular training in nursing education of medical rescue in manned space flight
Xiaopei GAO ; Peiming SUN ; Jing LI ; Liping DING ; Lianyong LI ; Junfeng GAO ; Xiaoming LIU ; Shuai MAO ; Yuxia CHENG
Chinese Journal of Emergency Medicine 2023;32(5):632-636
Objective:To study the application of scenario simulation teaching combined with modular training in nursing education of medical rescue in manned space flight.Methods:Twenty nurses from the medical rescue team of Strategic Support Force Characteristic Medical Center were selected as the research objects. The research objects were randomly divided into the scenario simulation combined with practical training group (practical training group, n=10) and traditional teaching group (control group, n=10). Scenario simulation teaching combined with modular training and traditional teaching were used to carry out nursing training. After the training, theoretical assessment, operation assessment and satisfaction survey were organized. Results:The scenario simulation teaching combined with modular training group was significantly better than the traditional training group in theory assessment, operation assessment and satisfaction survey of nursing staff (all P<0.05). Conclusions:Scenario simulation teaching combined with modular training has obvious teaching effect, which can improve the ability and quality of nursing staff, and help to complete the manned space medical rescue mission efficiently.
6.The characteristics and coping strategies of medical support mission in rescue and landing of Shenzhou-14 manned spacecraft
Peiming SUN ; Tao WANG ; Shuai MAO ; Xiaopei GAO ; Xiaoming LIU ; Junfeng GAO ; Jianwu YANG ; Heming YANG ; Ke LI
Chinese Journal of Emergency Medicine 2023;32(7):903-907
Objective:To review the characteristics and coping strategies of the rescue and landing medical support mission of Shenzhou-14 manned spacecraft.Methods:The characteristics of rescue and landing medical support mission of Shenzhou-14 manned spacecraft was analyzed, and the coping strategies and experience were discussed.Results:(1) The characteristics of rescue and landing medical support mission of Shenzhou-14 manned spacecraft included: long time in space station and high-intensity space missions; high-density space medical support mission in short term; special environmental factors in severe cold night; complex terrain of landing site; and the young medical support team. (2) The main coping strategies of rescue and landing medical support mission of Shenzhou-14 manned spacecraft included: strengthened the organization and leadership and improved the training model; reinforcement learning the medical treatment plan and strengthened the medical rescue skills training; optimized the carrying equipment and added the heat preservation and lighting measures; improved the medical rescue process and perfected the emergency plan; emphasized on the scientific research as important as mission; and strengthened the physical exercise and cold resistance exercise.Conclusions:The characteristics and coping strategies of rescue and landing medical support mission of Shenzhou-14 manned spacecraft are summarized to provide the experience for space medical rescue and offer the support for China's manned space industry.
7.The influence of special environment on peripheral veins and coping strategies during the space medical rescue mission of Shenzhou-13 spacecraft
Mingjie GAO ; Ming ZHAO ; Peiming SUN ; Jianwu YANG ; Lianyong LI ; Yuxia CHENG ; Heming YANG
Chinese Journal of Emergency Medicine 2022;31(7):876-881
Objective:To study the environmental characteristics of launch section during the space medical rescue mission of Shenzhou-13 spacecraft, evaluate the influence of special environment on peripheral veins, and investigate the coping strategies.Methods:Combined with the practice of launch section during space medical rescue mission of Shenzhou-13 spacecraft, the main factors of aerospace special environment, cold and faint light, were selected and the related literature was reviewed to explore the feasibility, advantages and disadvantages of peripheral venipuncture, central venous catheter and bone marrow puncture. The experience of the space medical rescue mission was summarized and the coping strategies were provided for follow-up task training.Results:The environmental characteristics of launch section during the space medical rescue mission of Shenzhou-13 spacecraft included cold, faint light, sand-wind and complex terrain. The vascular filling, vascular elasticity and visibility of peripheral vein decreased in different degrees under special environmental, the vascular visibility was most affected. The literature analysis showed that bone marrow puncture was a suitable method to establish infusion access in cold and faint light environment.Conclusions:The special environment of space launch mission has greater impact on peripheral veins. In order to assurance the successful implementation of manned space project, the training of basic operational skills should be consolidated, the training of ability in special environment should be enhanced and the advanced clinical auxiliary equipment should be equipped in follow-up space medical mission training.
8.Effect of breast external tissue expander assisted autologous fat transplantation in augmentation mammoplasty
Peiming ZHAI ; Liwei LI ; Qiuni GAO ; Chengsheng LIU ; Haibo XIE ; Hui AN ; Ping DING ; Peng CUI
Chinese Journal of Medical Aesthetics and Cosmetology 2021;27(6):469-473
Objective:To explore the method and experience of augmentation mammoplasty with autologous fat transplantation assisted by external expander.Methods:From January 2013 to December 2020, 352 female patients (698 breasts, 346 bilateral and 6 unilateral), aged from 18 to 55 years, with an average age of 41.5 years, were admitted to the Department of Cosmetic Surgery, Beijing Jingmei Medical Cosmetology Clinic. From 1-28 days before surgery, autologous fat transplantation was performed after wearing the dilator, and postoperative wearing of the dilator lasted from 1 to 24 months, with an average of 3.5 months.Results:The volume of fat transplantation per breast ranged from 150 ml to 460 ml, with an average of 320 ml. No obvious postoperative complications such as fat liquefaction, infection, intramammary induration and fat embolism were observed, and the postoperative appearance was lasting. The postoperative follow-up was conducted from 6 months to 7 years, and patient postoperative satisfaction rate reached 84.9% and doctors' satisfaction after surgery reached 82.1%.Conclusions:Augmentation mammoplasty with autologous fat transplantation assisted by external expander can effectively improve the appearance of breast morphology and contour defects and increase the survival rate of fat transplantation, which is worthy of clinical application.
9.Validation of ethylene oxide sterilization of disposable electronic analgesia infusion pumps
Wei MA ; Fuqiang LIU ; Peiming YE ; Min GAO ; Puyan HUANG
Shanghai Journal of Preventive Medicine 2022;34(9):906-910
IntroductionTo validate the effect of ethylene oxide sterilization of disposable electronic analgesia infusion pumps and determine the residual amount. MethodsAccording to ISO 11135:2014 Sterilization of Healthcare Products⁃Ethylene Oxide⁃Requirements for the Development, Validation and Routine Control of Sterilization Process for Medical Devices, qualification of physical cycle performance and microbial cycle performance were conducted on disposable electronic analgesia infusion pumps, and sterilization effect was then validated by using sterility test. According to ISO 10993⁃7:2008 Biological Evaluation of Medical Devices—Part 7: ethylene oxide sterilization residuals, the residual amount of ethylene oxide were further measured. ResultsThe sterilization effect fulfilled the requirements under the physical conditions of 38.0‒45.4 ℃ and 46%‒81% humidity. When the temperature was lower than 35 ℃ and the humidity was higher than 71%, the bacterial tablets remained fully activated after the sterilization with ethylene oxide. The shortest survival time without biological indicator after exposure to ethylene oxide was 8h. Furthermore, the residual amount of ethylene oxide after the sterilization was lower than the minimum detection limit. ConclusionAll tested products are sterilized. Sterilization equipment and sterilization process fulfilled the requirements of ISO 11135:2014. Additionally, the sterilization residual amount conforms to the limit values of ISO 10993⁃7:2008.