1.Effects of extensive or limited arthroscopic debridement in varying degrees of knees osteoarthritis
Jun YANG ; Wei TONG ; Yongjun ZHU ; Peilian XU ; Jiankui SHAO ; Shangru KUANG
Journal of Regional Anatomy and Operative Surgery 2015;(3):292-294
Objective To compare the clinical effects of extensive or limited arthroscopic debridement in varying degrees of knees osteo-arthritis. Methods 32 cases with knees osteoarthritis who underwent extensive debridement under arthroscopy were selected as the observa-tion group, and 30 cases with knees osteoarthritis who underwent limited debridement were selected as the control group. The excellent rate of joint function, Lysholm and VAS scores were compared between the two groups. Results The excellent rate of joint function were 90. 0%and 91. 4% in observation group and control group respectively, without significant difference (P>0. 05). Lysholm scores of patients with grade Ⅱ osteoarthritis was much higher in observation group than that in control group after operation (P<0. 05). There was no significant difference in Lysholm scores between gradeⅠand gradeⅢosteoarthritis (P>0. 05). No statistically significant difference of VAS scores on 1 year after operation were found (P>0. 05). Conclusion Extensive debridement and limited debridement under arthroscopy have similar effects for knees osteoarthritis. Extensive arthroscopic debridement is an ideal treatment method for Ⅱ grade of knees osteoarthritis.
2.Design and application of intra-abdominal pressure measuring device for children on peritoneal dialysis
Pei LU ; Qing ZHOU ; Xia SHEN ; Peilian YAO ; Qian SHEN ; Hong XU ; Xiaoyan FANG ; Rui ZHAO
Chinese Journal of Nephrology 2021;37(4):341-346
Objective:To design an intra-abdominal pressure measuring device applied to children on peritoneal dialysis (PD), and evaluate the feasibility and safety of the application of the device.Methods:The device consisted of a three-way stopcock with extension tubing, a three-way stopcock, a manometer tube, and a "Y" system peritoneal dialysis bag. The intraperitoneal pressure of different fill volumes was measured when a child was supine and relaxed in a horizontal position. The subjects of the study were children who received PD at the Pediatric Hospital of Fudan University from May 2019 to February 2020 and had PD dialysis age of>1 month. The children's demographic and clinical information were collected. During the measurement, the child’s complaints of pain, bloating, vital signs, and catheter-related contamination were recorded. Additionally, the occurrence of dialysis-related infections and complications during the hospitalization and outcomes of PD after three months of the measurement were tracked. A scatter plot and Pearson correlation test were used to explore the correlation between fill volumes and the intraperitoneal pressure.Results:Nine PD children were included in our study. The age of the children was (8.4±4.7) years old. The body surface area is (0.84±0.29) m 2. The intraperitoneal pressure was (12.6±1.9) cmH 2O at the fill volume of 1 000 ml/m 2 and (13.8±1.9) cmH 2O at the fill volume of 1 200 ml/m 2. The measurement was smoothly and safely taken without any case of contamination and dialysis-related infections during the hospitalization. After three months of the measurement, one child was transferred to temporary hemodialysis due to the aggravation of the umbilical hernia. Conclusions:The intraperitoneal pressure measuring device is feasible and safe to perform among children with PD. It can achieve non-invasive and continuous measurement of intra-abdominal pressure, and has guiding significance for the dialysis prescription of children with PD.
3.The meaning of the conception of scientific examination to create "Drug Testing in China" brand.
Chinese Journal of Medical Instrumentation 2011;35(2):131-133
Through the analysis of the current drug testing market, this paper discussion the meeting of creating "Drug Testing in China" brand on the concept of scientific testing.
China
;
Drug Industry
;
organization & administration
;
Pharmaceutical Preparations
;
Pharmaceutical Services
;
organization & administration
;
Quality Control
4.Discussion on the building of post market risk analysis method in hemodialysis device.
Honglei XU ; Xiaolong PENG ; Xiaojun TIAN ; Peilian WANG
Chinese Journal of Medical Instrumentation 2014;38(5):371-374
This paper discussed the building of post market risk analysis method in hemodialysis device from the point of government supervision. By proposing practical research methods for post market risk identification and estimation on hemodialysis device, providing technical guidance for government to put risk management of hemodialysis device into effect, and offering reference for enterprises to carry out post market risk evaluation on their products as well.
Government Regulation
;
Renal Dialysis
;
instrumentation
;
standards
;
Research Design
;
Risk Assessment
;
Risk Management