1.Establishment of Drug Release Determination Method for Methylphenidate Hydrochloride Bipolar Con-trolled Release Osmotic Pump Tablets
Qiongqiong XIA ; Hui LIU ; Peifang HE
China Pharmacist 2016;19(2):226-229,230
Objective:To establish the drug release determination conditions and method for methylphenidate hydrochloride bipolar controlled release osmotic pump tablets. Methods: The drug release of the tablets was determined by HPLC using a Diamonsil C18 (250 mm × 4. 6 mm, 5 μm) column with acetonitrile-KH2 PO4 (0. 02 mol·L-1 ,and pH was adjusted to 3. 0 by 1% H3 PO4 solution) (30∶ 70) as the mobile phase at a flow rate of 1 ml·min-1 , the column temperature was 35 ℃ and the injection volume was 20 μl. The effects of release medium, release apparatus and rotation speed on the release of methylphenidate hydrochloride bipolar controlled release osmotic pump tablets were studied as well. Results:The established drug release determination method had a good linear rela-tionship within the range of 1. 0-24. 0 μg·ml-1(r=0. 999 5), and the average recovery was 100. 5%(RSD=1. 58%, n = 6). Un-der the conditions of 900 ml pH 3. 0 phosphate buffer solution as the release medium and the rotation speed of 50 r·min-1 , the drug was quickly released in 0-2h, and then the release behavior was complied with a zero-level model in vitro in 2-10h with the release e-quation of Q=5. 505t+44. 221(r=0. 994 5). Conclusion:The method is simple, accurate and reliable, and suitable for the quality control of methylphenidate hydrochloride bipolar controlled release osmotic pump tablets.
2.Expression of zinc finger protein A20 mRNA of mouse liver tissues after trauma with lipopolysaccharide infection
Bo LIU ; Jianxin JIANG ; Peifang ZHU
Chinese Journal of Trauma 2003;0(09):-
Objective To study the expression law of zinc finger protein A20 mRNA of mouse liver tissues in the process of trauma with lipopolysaccharide (LPS) infection. Methods A total of 95 healthy mice (either sex, from Kunming, Yunnan province) with a mean body weight of 21 g (18-24 g) were randomized into 4 groups: control, trauma only (Group A), LPS only (Group B) and trauma plus LPS (Group C). The models with closed fracture of bilateral spines as well as endotoximia were made. The expression characteristics of zinc finger protein A20 mRNA of liver tissues were measured by reverse transcription-polymerase chain reaction (RT-PCR) and all result data expressed as total gray ratio of A20 mRNA to GAPDH mRNA (?s). Results In the control group, the A20 mRNA expressed at a low level. There was low expression of zinc finger protein A20 in the Group A at various time points, with no significant difference compared with the control group. After LPS infection, the expression of A20 mRNA in the Group B was elevated more obviously than that in the control group at 0.5 hour, reached peak during 0.5-2 hours and decreased after 2 hours. But expression of A20 mRNA at each time point was higher in the Group B than that in the Group A. In the Group C, after LPS infection, the expression of A20 mRNA was elevated more significantly than that in other two groups 0.5 hour, reached the highest level during 0.5-2 hours, much higher than that in the Group B (P
3.X-ray Diagnosis and Pathological Study of Ductal Carcinoma in Situ of Breast
Yumei ZHAO ; Peifang LIU ; Junyi ZHANG
Journal of Practical Radiology 2000;0(02):-
Objective To discuss the value of the mammography in the diagnosis of ductal carcinoma in situ (DCIS) and guidelines ofthe operation.Methods 107 pathologically proved DCIS were retrospectively reviewed.Results There were 62 microcacifications(57.9%),the range of microcacifications was varied , of them,13 were masses or local compact with microcacifications ; 17 were localized infiltration and bad structure (15.9%);20 were masses (18.7%) ;1 papillae enhancement (0.9%),7 were normal(6.5%).Conclusion Multiplicity microcacifications are the most frequently appearance of X-ray in DCIS;mammography could find the early microcarcinoma and the early carcinoma , especially the DCIS ; mammography could exactly reflect the multifocus , it is of value in confirming the range of the operation.
4.The effects of prostacyclin on the changes of basic fibroblast growth factor after lung injury in dogs
Guojian LIU ; Zhengguo WANG ; Peifang ZHU ;
Journal of Third Military Medical University 1984;0(02):-
The separation,purification and activity determination of basic fibroblast growth factor (bFGF) with nucleic acid molecular hybridization was described and the changes of bFGF in lung injury treated with prostacy-clin were observed.It was found that bioactive bFGF and bFGF-mRNA could only be found in the injured lung tissues but not in the normal lungs.Administration of prostacyclin could slightly elevate the activity of bFGF and signficantly increase the level of bFGF-mRNA.The findings of this study suggest that there is an increase of bFGF level after lung injury,prostacyclin can influence the expression of bFGF,and bFGF plays an important role in the repair of the injured lung tissues.
5.Correlation study of effect of additional filter on radiation dose and image quality in digital mammography
Jie LIU ; Peifang LIU ; Hongbin WANG ; Shuping ZHANG ; Xueou LIU
Chinese Journal of Radiology 2012;(12):1079-1082
Objective To explore the effect of different additional filters on radiation dose and image quality in digital mammography.Methods Hologic company's Selenia digital mammography machine and the post-processing workstations and 5 M high resolution medical monitor were used in this study.Mammography phantoms with the thickness from 1.6 cm to 8.6 cm were used to simulate human breast tissue.The same exposure conditions,pressure,compression thickness,the anode were employed with the additional filters of Mo and Rh under the automatic and manual exposure mode.The image kV,mAs,pressure,filter,average glandular dose (AGD),entrance surface dose (ESD),signal-to-noise ratio (SNR),contrast-to-noise ratio (CNR) and image score according to ACR criteria were recorded for the two additional filters.Paired sample t test was performed to compare the indices of Mo and Rh groups by using SPSS 17.0.Results AGD and ESD of Rh and Mo group were both higher with the increase of the thickness of all the phantoms.AGD,ESD and their increased value of Rh filter(1.484 ± 1.041,7.969 ± 7.633,0.423 ± 0.190 and 3.057 ± 2.139) were lower than those of Mo filter(1.915 ± 1.301,12.516 ± 11.632,0.539 ±0.246 and 4.731 ± 3.294),in all the phantoms with different thickness (t values were 4.614,3.209,3.396 and 3.605,P <0.05).SNR,CNR,and image score of Rh and Mo group both decreased with the increase of the thickness of all the phantoms.There were no statistical difference (P > 0.05).Conclusions Compared with Mo filter,Rh filter could reduce the radiation dose,and this advantage is more obvious in the thicker phantom when the same image quality is required.
6.Development of symptom check list 90 norm in employees of China National Petroleum Corporation
Yingli LIU ; Shan JIANG ; Yiping LAN ; Peifang TAN
Chinese Journal of Health Management 2012;(6):371-375
Objective To establish symptom check list 90 (SCL-90) norm for Chinese oilmen.Methods Based on multi-level stratified or cluster sampling technique,a total of 13 472 oilmen from China National Petroleum Corporation completed a sampling survey on measured data of SCL-90.Student's t test and one-way analysis of variance (ANOVA) were used to compare gender,age,education level and marriage status.Results All the reliability coefficients were > 0.8 and P for validity test was < 0.05.In comparison with SCL-90 norm of healthy Chinese adults in 1986,the interpersonal sensitive (1.5 ± 0.6)and paranoia (1.4 ± 0.6) of oilmen were lower (t≤-4.17,both P < 0.05),although other 8 factors showed higher scores (t ≥ 2.4,all P < 0.05).Oilmen also had lower scores for each item than Chinese army men (t ≤-2.62,all P < 0.05).Total score (131.4 ± 47.7),interpersonal sensitive (1.4 ± 0.6),hostility (1.5 ± 0.6),paranoia (1.4 ± 0.6) and psychosis (1.3 ± 0.5) of females were lower than those of males (t≥2.53,all P < 0.05).30-39 years group indicated the highest scores for each item (all P <0.05),while 17-29 years group got the lowest (all P < 0.05).Meanwhile,the subjects whose education level was equate to or lower than high school or those got married were found to have the highest scores (all P < 0.05).Conclusions Our data show better item differentiation,reliability and validity of SCL-90.SCL-90 norm may be used for mental health assessment of Chinese oilmen.
7.Enhancement characterization of breast masses of contrast-enhanced ultrasound: comparison with MRI
Xiaokang LI ; Ying ZHU ; Peifang LIU ; Yilin XU ; Zhenzhen SHAO
Chinese Journal of Ultrasonography 2014;23(1):44-48
Objective To assess the enhancement characteristic of breast lesions of contrast-enhanced ultrasound (CEUS) in comparison with contrast-enhanced magnetic resonance imaging (MRI).Methods Between August 2011 and March 2013,72 women with 72 lesions were enrolled.All patients underwent ultrasound,CEUS and MRI.The histopathologic results obtained from ultrasound-guided core biopsy or operation excisions were used as the reference standard.CEUS section evaluations were made similar with MRI regarding the size and shape of lesions.Different contrast enhancement patterns including homogeneous/heterogeneous,the tumor areas,the perfusion defect areas,and modality of time-intensity curve were evaluated.Pearson's correlation coefficient,Student's t-tests,and the concordance test were used for evaluation.Results Of the 72 lesions,pathologic examination revealed 56 (77.8%) malignant lesions and 16 (22.2%) benign lesions.The tumor areas measured by CEUS and MRI agreed well,with a correlation of r =0.894,P =0.000.The difference between the two measurements was not significant according to a paired t test (P =0.886).The concordance tests gave a value of the coefficient Kappa =-0.153 (P =0.061),indicating a low concordance between the results obtained with CEUS and those obtained with MRI regarding the enhanced uniformity.There were statistically significant differences in the perfusion defect areas as measured by CEUS and MRI (P =0.01).The CEUS estimates [(0.837 ± 0.827)cm2] were consistently higher than the MRI estimates [(0.576 ± 0.524)cm2].The time-intensity curve patterns between the two groups showed no correlation.Conclusions The enhancement patterns evaluated by CEUS and MRI partly agreed well.There was no direct association between the two methods regarding the enhancement patterns because of the different contrast agent.
8.MRI features of mucinous carcinoma of the breast: correlation with histopathology
Peifang LIU ; Lu YIN ; Yun NIU ; Runxian HAO
Chinese Journal of Radiology 2009;43(5):470-475
Objective To characterize the features of breast mucinous carcinoma on T2WI, dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion weighted imaging (DWI) and correlate the MR features with histopathology. Methods MR imaging in 8 women (aged 33--65 years old) with mncinous carcinoma of the breast verified histopathologically was performed on 1.5 T scanner with T1WI, FS T2 WI, 3D DCE-MRI using volume imaging for breast assessment(VIBRANT) sequence, DWI with b value of 500 and 1000 s/mm2 by single-shot EPI sequence. According to the lexicon of BI-RADS-MRI designed by ACR, the MR findings were retrospectively studied, including morphology, signal intensity on T1WI and FS T2WI, mass enhancement, the patterns of dynamic enhancement curve, and the mean ADC on DWI. The pathologic diagnosis was made according to the standard criteria by the World Health Organization Classification of Tumors. Results Five patients were pure mucinous carcinoma and 3 patients were the mixed. The amount of mucus ranged from 60% to 90%. All 8 tumors presented as a mass on MRI with low signal intensity on T1WI, high or strongly high signal intensity on FS T2WI and high signal on DWI. The tumor size ranged from 1.3 to 3. 2 cm in diameter. Five tumors showed rim enhancement in early phase and the central part was gradually enhanced in delayed phase. One tumor presented slightly heterogeneous enhancement. Two tumors showed progressively heterogeneous enhancement. The mean ADC values of tumor were (2.41±0.28) ×10-3 mm2/s with b value of 500 s/mm2 and (2.06 ±0. 14) × 10-3 mm2/s with b value of 1000 s/mm2, and higher than that of the normal breast tissue [ ( 1.71 ±0. 32) × 10-3 and ( 1.43 ± 0. 24) × 10-3 mm2/s]. Conclusions The MR features of breast mucinous carcinoma on T1WI, DCE-MRI, and DWI are different from that of invasive ductal carcinomas and may reflect its distinct histological type. The combination of these MR sequences may lead to a pre-operative diagnosis of this tumor.
9.Breast MRI in detecting primary malignancy of patients presenting with axillary metastases and negative X-ray mammography
Xiaokang LI ; Yilin XU ; Peifang LIU ; Hong LU ; Shuping ZHANG
Chinese Journal of Radiology 2011;45(4):348-352
Objective To evaluate the role of breast MRI in detecting the primary malignancy in patients presenting solely with axillary lymph node metastases. Methods Thirty-three patients with axillary lynph node metastases but negative findings on either physical examination or mammography underwent breast MRI to identify occult breast carcinoma. MRI of the breast was assessed according to BI-RADS criteria. The pathologic diagnosis was made according to the standard criteria by the WHO Classification of Tumor. Results Among 33 patients presenting solely with axillary metastases, 30 patients underwent modified radical mastectomy. Primary breast carcinoma was proven in 17 patients. MRI detected lesions in 16 patients, including 10 masses and 6 non-mass lesions. Size of the masses ranged from 0. 5 to 2. 6 cm (mean 1.5 cm). Six lesions were smaller than 1.5 cm in size. Non-mass lesions showed ductal enhancement in 4 cases and segmental enhancement in 2 cases. One patient with tumor detected by histopathology showed no abnormal enhancement on MRI. No tumor was found at mastectomy in the other 13 womeu, and negative MR findings were revealed in 9. Four cases with suspicious enhancement on MRI had no corresponding primary foci on pathology. Three patients didn't undergo surgical procedure. The sensitivity, specificity, and accuracy of MRI in the diagnosis of the primary malignancy were 94. 1%,69. 2%, and 83.3%, respectively. Conclusions Small size of mass and ductal or segmental enhancement of non-mass lesion were common MR features of occult malignancy. MRI showed high sensitivity and accuracy in diagnosing occult breast carcinoma. Breast MRI should be taken in search of occult malignancy in patients with axillary metastases.
10.Changing of pulmonary surfactants after Severe Steam Inhalation Injury in Rabbits
Zhiyuan LIU ; Ngao LI ; Peifang CHU ; Chongcheng YANG ; Jintang SHUI
Journal of Third Military Medical University 1984;0(01):-
Surface tension(in terms of hysteresis), lecithin content, PaO2 and lung water content of both bronchial irrigation fluid and lung homogenates were determined after severe inhalation injury in rabbits. In accompany with the decrease of PaO2 and increase of lung water content, there was a remarkable dropping of pulmonary surfactant content as illustrated by progressive increase of surface tension and decrease of lecithin content in both bronchial irrigation fluid and lung homogenate. It was proposed that dropping of pulmonary surfactant played an important role in the pathogenesis of pulmonary edema after inhalation injury. Therefore, successive determinations of lecithin content or and surface tension of bronchial irrigation fluid might serve as an early diagnosis as well as a pro-gnostis aid in severe inhalation injuries.