1.Determination of Rosmarinic Acid in Herba Rabdosiae Serrae by HPLC
Guifan WU ; Qingquan HUANG ; Peide XIE ; Yi LUO
China Pharmacy 2016;27(24):3422-3424
OBJECTIVE:To establish a method for rosmarinic acid in Herba Rabdosiae Serrae. METHODS:HPLC method was performed on the column of Inertsil ODS-SP C18 with mobile phase of acetonitrile-0.4% phosphoric acid(gradient elution)at a flow rate of 1.0 ml/min,the detection wavelength was 327 nm,column temperature was 25 ℃,and injection volume 10 μl. RE-SULTS:The linear range of rosmarinic acid was 5.039-100.776 μg/ml(r=0.999 6),RSDs of precision,stability and reproducibility tests were lower than 3%;recovery was 99.53-104.38%(RSD=2.06%,n=9). CONCLUSIONS:The method is simple with good reproducibility and high accuracy,and can be used for the content determination of rosmarinic acid in Herba Rabdosiae Serrae.
2.Clinical study on 3D printing technology in percutaneous nephrolithotripsy for complicated renal calculi
Zhenghua WAN ; Liming XU ; Peide BAI ; Shunqiang XIE ; Jiguang XIAO ; Kuifu CHEN ; Weibin ZHANG ; Bin CHEN
Chinese Journal of Urology 2021;42(3):170-175
Objective:To explore the clinical application value of 3D printing technology in percutaneous nephrolithotomy(PCNL) to complex renal calculi.Methods:The clinical data of 41 patients with complex renal calculi from May 2018 to October 2019, in the First Affiliated Hospital of Xiamen University and Xiang'an District of the First Affiliated Hospital of Xiamen University were retrospectively analyzed. There were 19 cases underwent PCNL after 3D printing (3D printing group), and 22 cases during the same period did not undergo 3D printing before operation (control group). Before operation, the two groups underwent CT plain scan enhanced examination. In 3D printing group, 3D printing technology was used to obtain 3D renal models, then 3D renal models were used for preoperative design and simulation of surgical puncture and preoperative conversation.The control group only underwent PCNL after routine examination.The ages of the patients in 3D printing group and control group were (42.9±2.5) vs. (41.3±2.9) years old, male/female ratio 11/8 vs. 12/10, body mass index (22.4±1.1) vs. (23.2±1.4) kg/m 2, serum creatinine (42.9±2.5) vs. (78.2±4.5) μmol/L, stone size (5.0±1.2) vs. (5.2±1.3) cm, the CT values of the stones was (930±210) vs.(950±200) HU. The difference of above parameters was not statistically significant ( P>0.05). The following indexes were compared between the two groups: score of questionnaire on satisfaction of preoperative conversation, and datas about operation and postopetation. Results:All the operations were successfully completed. The time of locating the target calyces in 3D printing group and control group was (3.3±1.3) vs. (5.3±3.1) min, and the coincidence of puncture calices was 94.7% (18/19) vs. 54.5%(12/22), and the stone removal rate of the 3D printing group was 78.9% (17/19) vs. 36.4% (8/22), 3D printing group was better than the control group in these respects( P < 0.05). However, there were no significant differences in postoperative complications [21.0% (4/19) vs. 13.6% (3/22)], multi-channel[89.4% (17/19) vs. 86.4% (19/22)], operation time [(121.8±20.2) vs. (132.1±18.5) min], time of hospitalization [(7.6±1.3) vs. (8.0±1.8)d] and time of extubation for renal fistula [(3.8±1.7)vs. (4.5±2.0 )d] (all P > 0.05). During preoperative conversation between the 3D printing group and the control group , the time spent on signing the consent [(17.0±3.9) vs.(21.0±3.3) min], the degree of understanding of the stone condition [(2.5±0.6)vs.(2.0±1.2) points], the degree of understanding of the PCNL surgical process and complications [(2.6±0.6) vs.(1.8±1.3) points] and the degree of satisfaction with the doctor’s preoperative conversation effects [(2.4±0.9) vs.(1.7±1.6) points]were significantly different in comparisons ( P<0.05). Conclusions:3D printing technology can be used in PCNL to directly display the internal anatomical relationship of renal calculi, guide accurate preoperative designing, help improve the operation efficiency and stone clearance rate, and can also be used as a mold in preoperative conversation to improve communication efficiency.
3.HPLC Fingerprint of Yanhuanglian Injections
Yuanxiu LUO ; Dongxu WEN ; Shoujun JIANG ; Jinian JIANG ; Youcheng XU ; Peide XIE ; Xianglin ZENG
Chinese Traditional and Herbal Drugs 1994;0(07):-
Objective To establish the HPLC fingerprint for the quality control of Yanhuanglian Injections.Methods HPLC Chromatography method was used.The conditions included a Shim-pack CLC-ODS column(250 mm?6.0 mm,5 ?m),the gredient elution was adopted with acetonitrile-buffer solution(1∶1),the detection wavelength was at 285 nm,and the flow rate was 1.0 mL/min.The Operating Standard of Similarty Evaluation System for Chromatographic Fingerprint of Chinese Materia Medica(Version 2004A)was used to calculate.Results Similarity of 13 batches of injections was over 0.95,the fingerprint of Yanhuanglian Injections was established,and 12 common peaks were indicated.Conclusion This method can be applied to the quality control of Yanhuanglian Injections.
4. The mechanism of Annexin A1 regulating the proliferation, apoptosis and migration of bladder cancer cells
Tao WANG ; Peide BAI ; Shunqiang XIE ; Anran SUN ; Jinchun XING ; Bin CHEN
Chinese Journal of Urology 2019;40(12):932-936
Objective:
Explore the function and regulatory mechanism of Annexin A1 (ANXA1) in bladder cancer cell proliferation, apoptosis and migration.
Methods:
From February 2018 to June 2019, we use T24 cells as the model and divide it into over-expression control group (ctrl), ANXA1 over-expression group (ANXA1), knockdown control group (shctrl), ANXA1 knockdown group 1 (shANXA1-1), ANXA1 knockdown group 2 (shANXA1-2) and ANXA1 knockdown group 3 (shANXA1-3). 24 hours after the culture, the cells were collected and the mRNA expression level of ANXA1 was detected by Real-Time quantitative PCR. The cell activity was detected by CCK-8; the cell apoptosis and cycle were detected by flow cytometry. The cell migration was detected by Transwell assay.
Results:
The Real-Time quantitative PCR showed that the expression of ANXA1 in the over expression group was significantly higher than that in the over expression control group (15 369.00±874.20 and 1.00±0.07,
5.Simultaneous Determination of 4 Components in Xinyi Biyan Pills by HPLC-switching Wavelength Method
Lili HUANG ; Yi LUO ; Guifan WU ; Peide XIE ; Tao ZHANG
China Pharmacy 2018;29(5):625-628
OBJECTIVE: To establish the method for simultaneous determination of pim-O-glucosylcimifugin, liquiritin, 5-0-methylvisammioside and amonium glycyrrhizinate in Xinyi byan pills.METHODS: HPLC-switching wavelength method was used for content determination of 52 batches of Xinyi byan pills sample from enterprises A, B, C. The determination was performed on Kromasil C18 column with mobile phase consisted of acetonitrile-0. 1 % phosphoric acid at the flow rate of 1. 0 mL/min. The detection wavelengths were set at 220 nm (pim-O-glucosylcimifugin, liquiritin, 5-O-methylvisammioside) and 250 nm (amonium glycyrrhizinate). The column temperature was 30℃, and sample size was 10 μ L. RESULTS: The linear ranges of prim-O-glucosylcimifugin, liquiritin, 5-O-methylvisammioside and amonium glycyrrhizinate were 6. 138-122. 77 μg/mL (r=0. 999 9), 2. 502-50. 03 μg/mL (r=0. 999 9), 5. 988-119. 75 μg/mL (r=0. 999 9) and 12. 788-255. 76 μg/mL (r=0. 999 9), respectively. RSDs of precision, stability and reproducibility tests were all lower than 2. 0% (n=6). The recovery rate were 100. 32% (RSD=0. 58%, n=6), 100. 24% (RSD=0. 56%, n=6), 101. 28% (RSD=0. 91%, n=6) and 101. 48% (RSD=0. 79%, n=6), respectively. Total contents of 4 components in enterprise A were generally higher than enterprises B, C, among which the difference of liquiritin was significant; the content of prim-O-glucosylcimifugin in enterprise B was higher than enterprises A, C, while the content of 5-O-methylvisammioside was lower than enterprises A, C. The content of liquiritin in enterprise B was outlier. CONCLUSIONS: This method is simple, reproducible and can provide reference for quality control of Xinyi biyan pills.