1.Innervation of cerebral vessels and pathogenesis of migraine
Journal of the Japan Society of Acupuncture and Moxibustion 2010;60(1):23-31
Although migraine is not life-threatened disease, its burden in migraineurs is enough severe to affect the productivity in the society around them. Triptans, the most effective agents for the pain in the migraine attacks, have been available since 2000 in Japan. After then, the strategy for migraine treatment has been drastically changed. It has also affected the concept for migraine pathogenesis. Migraine has been attributed to certain abnormality in the cerebral blood vessels per se. However, the trigeminal nerve endings around cerebral or dural vessels are considered to play the key role in the migraine attacks since appearance of the triptans (i.e., trigeminovascular theory). Moreover, recent researches imply many possibilities of the 'migraine generator(s)'in the central nervous system.
2.The Efficacy of Conventional Aortic Valve Replacement for Severe Aortic Valve Stenosis Divided by Risk Classification Using the Japanese Scoring System
Kazuyuki Daitoku ; Kaoru Hattori ; Wakako Fukuda ; Norihiro Kondo ; Satoshi Taniguchi ; Masahito Minakawa ; Kozo Fukui ; Yasuyuki Suzuki ; Ikuo Fukuda ; Hiroyuki Itaya
Japanese Journal of Cardiovascular Surgery 2014;43(2):43-48
Objective : Transarterial or transapical aortic valve replacement (TAVR) procedures have been performed for high-risk patients with severe aortic valve stenosis (AS) in western countries. A high-risk patient is defined as having an STS score greater than 10%. In Japan, aortic valve replacement (AVR) with cardiopulmonary bypass (CPB) is standard care for AS, even if the patient is at high risk of developing complications. We calculated an expected operative risk of patients using a JAPAN score established by Japanese Adult Cardiovascular Surgery Database (JACVSD). Patients and Methods : Patients were divided into three groups : score less than 5%, low risk (LR) ; score 5-10%, moderate risk (MR) ; score more than 10%, high risk (HR). We also evaluated the efficacy of conventional AVR in each group. Between January 2002 and May 2011, we performed conventional AVR in our hospital and 116 patients who underwent AVR for symptomatic AS were enrolled in this study. Results : There were 79 patients in the LR group, 30 patients in the MR group and 7 patients in the HR group. The mean score was 2.6±1.1% in the LR group, 6.8±1.4% in the MR group and 23.3±16.8% in the HR group respectively. The mean follow-up period was 7.6±0.3 years. Preoperative co-morbidity was not statistically significant among three groups, however more octogenarians were found in the HR group. The aortic valve area and left ventricular ejection fraction (LVEF) were significantly smaller in the HR group. There were 4 cancer patients. The HR group had significantly longer operation and CPB times than the LR group. The operative mortality in all cases was 1.6%. Overall survival at 5 years was 78%. Actual survival at 5 years was 77% in the LR group, 82% in the MR group and 71% in the HR group. The major adverse cardiac and cerebrovascular event (MACCE)-free ratio at 5 years was 85%. Absence of death caused by MACCE at 5 years was 93%. All cancer patients died after AVR due to advancement in cancer. Conclusion : The results of conventional AVR with CPB were satisfactory in each group. Cancer patients may be good candidates for TAVR in the future.
3.Diagnostic accuracy of neuropsychological tests for classification of dementia
Takuya Yagi ; Daisuke Ito ; Daisuke Sugiyama ; Satoko Iwasawa ; Hajime Tabuchi ; Mika Konishi ; Machiko Araki ; Naho Saitoh ; Yoshihiro Nihei ; Masaru Mimura ; Norihiro Suzuki
Neurology Asia 2016;21(1):47-54
Although numerous studies have shown that each neuropsychological test is effective for diagnosing
mild cognitive impairment (MCI) or Alzheimer’s disease (AD), studies comparing diagnostic accuracies
of various neuropsychological tests are relatively rare and practical cutoff values are not available. The
present study aimed to investigate the validity of neuropsychological tests and develop cutoff values
for each in differentiating healthy control (HC), MCI and AD groups. A total of 84 HC, 187 with
MCI and 195 with AD were evaluated by the selected seven neuropsychological tests using receiver
operating characteristic (ROC) curve analysis. Logical Memory (LM) delayed recall (cutoff, 7) and
Rey Auditory Verbal Learning Test (RAVLT) delayed recall (cutoff, 6) were effective for differentiating
HC from MCI. To distinguish MCI and AD, Rey Osterrieth Complex Figure Test (ROCFT) 3 mindelayed
recall (cutoff, 6) and LM immediate recall (cutoff, 4) were excellent. Delayed recall of verbal
materials, as indexed by LM and RAVLT was sensitive for discriminating MCI from HC. Handling
visual memory traces, as indexed by ROCFT and immediate verbal information by LM were sensitive
for differentiating MCI and AD.
Alzheimer Disease
;
Dementia
;
Neuropsychological Tests
4.C5 Palsy of Patients with Proximal-Type Cervical Spondylotic Amyotrophy
Yasuaki IMAJO ; Norihiro NISHIDA ; Masahiro FUNABA ; Yuji NAGAO ; Hidenori SUZUKI ; Takashi SAKAI
Asian Spine Journal 2022;16(5):723-731
Methods:
Sixty patients with PCSA who underwent surgical treatment of the cervical spine were enrolled. The radiological findings on plain radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) were evaluated. The cervical lordotic angles, C2–C7 sagittal vertical axis (SVA), and T1 slope were assessed on a lateral radiograph in the neutral position. CT was used to assess the width of the intervertebral foramen and the anterior protrusion of the superior articular process on the axial view. MRI was used to determine the number of levels of compression (NLC) and the presence of a high-intensity area in the spinal cord in the T2- weighted midsagittal view. The preoperative and postoperative strengths of the most atrophic muscles were evaluated using manual muscle testing. Improvements in strength were classified as excellent (five grades recovered), good (more than one grade recovered), fair (no improvement), or poor (worsened).
Results:
The prevalence of C5 palsy was 17% (10/60). Patients with poor outcomes had higher NLC and Δ C2–C7 SVA than patients with excellent, good, and fair outcomes (p =0.015; odds ratio [OR], 5.758; 95% confidence interval [CI], 1.397−23.726 for a change of 10% and p =0.048; OR, 1.068; 95% CI, 0.992−1.141 for a change of 10%, respectively).
Conclusions
ΔC2–C7 SVA and NLC may be used as prognostic factors for achieving a poor outcome following surgery in patients with PCSA. More focus is needed on preventing the increase in ΔC2–C7 SVA.
5.Transcatheter Arterial Chemotherapy with Miriplatin for Hepatocellular Carcinoma Patients with Chronic Renal Failure: Report of Three Cases.
Norihiro IMAI ; Kenji IKEDA ; Yuya SEKO ; Yusuke KAWAMURA ; Hitomi SEZAKI ; Tetsuya HOSAKA ; Norio AKUTA ; Masahiro KOBAYASHI ; Satoshi SAITOH ; Fumitaka SUZUKI ; Yoshiyuki SUZUKI ; Yasuji ARASE ; Hiromitsu KUMADA
Gut and Liver 2013;7(2):246-251
Miriplatin is a novel lipophilic platinum complex that was developed to treat hepatocellular carcinoma (HCC). Although HCC patients frequently have coexisting chronic renal failure, little prospective data are available regarding the clinical toxicity of chemotherapeutic agents used to treat HCC patients with chronic renal failure. In a phase II study, the plasma concentration of total platinum in patients who received miriplatin was very low, and no severe renal toxicity caused by miriplatin injection was reported. Here, we present three cases of HCC with stage 4 chronic renal failure who received transcatheter arterial chemotherapy with miriplatin. All cases were male, ages 72, 84, and 83 years, and had serum creatinine levels of 2.3, 1.6, and 1.9 mg/dL, respectively. Their estimated glomerular filtration rates were 21.9, 20.3, and 22.2 mL/min, respectively. All cases were treated for unresectable HCC with transcatheter arterial chemotherapy with miriplatin. No serious adverse events were observed, and serum creatinine levels did not elevate, even in the patient who experienced renal failure caused by cisplatin administration. These results might suggest that transcatheter arterial chemotherapy with miriplatin can be safely used in HCC patients with chronic renal failure.
Carcinoma, Hepatocellular
;
Cisplatin
;
Creatinine
;
Glomerular Filtration Rate
;
Humans
;
Kidney Failure, Chronic
;
Male
;
Organoplatinum Compounds
;
Plasma
;
Platinum
;
Renal Insufficiency
6.Frequency and clinical features of deficient mismatch repair in ovarian clear cell and endometrioid carcinoma
Tamaki TANAKA ; Kazuhiro TAKEHARA ; Natsumi YAMASHITA ; Mika OKAZAWA-SAKAI ; Kazuya KURAOKA ; Norihiro TERAMOTO ; Kenichi TAGUCHI ; Katsushige YAMASHIRO ; Hidenori KATO ; Tomoya MIZUNOE ; Rie SUZUKI ; Dan YAMAMOTO ; Arisa UEKI ; Toshiaki SAITO
Journal of Gynecologic Oncology 2022;33(5):e67-
Objective:
To clarify the frequency of deficient mismatch repair (dMMR) in Japanese ovarian cancer patients, we examined microsatellite instability (MSI) status and immunohistochemistry (IHC) subtypes, including endometrioid carcinoma (EMC), clear cell carcinoma (CCC), or a mixture of both (Mix).
Methods:
We registered 390 patients who were diagnosed with EMC/CCC/Mix between 2006 and 2015 and treated at seven participating facilities. For 339 patients confirmed eligible by the Central Pathological Review Board, MSI, IHC, and MutL homolog 1 methylation analyses were conducted. The tissues of patients with Lynch syndrome (LS)-related cancer histories, such as colorectal and endometrial cancer, were also investigated.
Results:
MSI-high (MSI-H) status was observed in 2/217 CCC (0.9%), 10/115 EMC (8.7%), and 1/4 Mix (25%). Additionally, loss of MMR protein expression (LoE-MMR) was observed in 5/219 (2.3%), 16/115 (14.0%), and 1/4 (25%) patients with CCC, EMC, and Mix, respectively. Both MSI-H and LoE-MMR were found significantly more often in EMC (p<0.001). The median (range) ages of patients with MMR expression and LoE-MMR were 54 (30–90) and 46 (22–76) (p=0.002), respectively. In the multivariate analysis, advanced stage and histological type were identified as prognostic factors.
Conclusion
The dMMR rate for EMC/CCC was similar to that reported in Western countries. In Japan, it is assumed that the dMMR frequency is higher because of the increased proportion of CCC.
7.Patient-specific mechanical analysis of pedicle screw insertion in simulated osteoporotic spinal bone models derived from medical images
Norihiro NISHIDA ; Hidenori SUZUKI ; Hanvey TETSU ; Yuki MORISHITA ; Yogesh KUMARAN ; Fei JIANG ; Masahiro FUNABA ; Kazuhiro FUJIMOTO ; Yusuke ICHIHARA ; Takashi SAKAI ; Junji OHGI
Asian Spine Journal 2024;18(5):621-629
Methods:
Male and female patients with computed tomography data were selected. Dimensions of the first thoracic (T1), fourth lumbar (L4), and fifth lumbar (L5) vertebrae were measured, and bone models consisting of the cancellous and cortical bones made from polyurethane foam were created. PS with diameters of 4.5 mm, 5.5 mm, and 6.5 mm were used. T1 PS were 25 mm long, and L4 and L5 PS were 40 mm long. The bone models were secured with cement, and the MIT was measured using a calibrated torque wrench. After MIT testing, the PS head was attached to the machine’s crosshead. POS was then calculated at a crosshead speed of 5 mm/min until failure.
Results:
The L4 and L5 were notably larger in female bone models, whereas the T1 vertebra was larger in male bone models. Consequently, the MIT and POS for L4 and L5 were higher in female bone models across all PS diameters than in male bone models. Conversely, the MIT for T1 was higher in male bone models across all PS; however, no significant differences were observed in the POS values for T1 between sexes.
Conclusions
The mechanical properties of the proposed bone models can vary based on the vertebral structure and size. For accurate 3D surgical and mechanical simulations in the creation of custom-made medical devices, bone models must be constructed from patientspecific medical images.
8.Patient-specific mechanical analysis of pedicle screw insertion in simulated osteoporotic spinal bone models derived from medical images
Norihiro NISHIDA ; Hidenori SUZUKI ; Hanvey TETSU ; Yuki MORISHITA ; Yogesh KUMARAN ; Fei JIANG ; Masahiro FUNABA ; Kazuhiro FUJIMOTO ; Yusuke ICHIHARA ; Takashi SAKAI ; Junji OHGI
Asian Spine Journal 2024;18(5):621-629
Methods:
Male and female patients with computed tomography data were selected. Dimensions of the first thoracic (T1), fourth lumbar (L4), and fifth lumbar (L5) vertebrae were measured, and bone models consisting of the cancellous and cortical bones made from polyurethane foam were created. PS with diameters of 4.5 mm, 5.5 mm, and 6.5 mm were used. T1 PS were 25 mm long, and L4 and L5 PS were 40 mm long. The bone models were secured with cement, and the MIT was measured using a calibrated torque wrench. After MIT testing, the PS head was attached to the machine’s crosshead. POS was then calculated at a crosshead speed of 5 mm/min until failure.
Results:
The L4 and L5 were notably larger in female bone models, whereas the T1 vertebra was larger in male bone models. Consequently, the MIT and POS for L4 and L5 were higher in female bone models across all PS diameters than in male bone models. Conversely, the MIT for T1 was higher in male bone models across all PS; however, no significant differences were observed in the POS values for T1 between sexes.
Conclusions
The mechanical properties of the proposed bone models can vary based on the vertebral structure and size. For accurate 3D surgical and mechanical simulations in the creation of custom-made medical devices, bone models must be constructed from patientspecific medical images.
9.Patient-specific mechanical analysis of pedicle screw insertion in simulated osteoporotic spinal bone models derived from medical images
Norihiro NISHIDA ; Hidenori SUZUKI ; Hanvey TETSU ; Yuki MORISHITA ; Yogesh KUMARAN ; Fei JIANG ; Masahiro FUNABA ; Kazuhiro FUJIMOTO ; Yusuke ICHIHARA ; Takashi SAKAI ; Junji OHGI
Asian Spine Journal 2024;18(5):621-629
Methods:
Male and female patients with computed tomography data were selected. Dimensions of the first thoracic (T1), fourth lumbar (L4), and fifth lumbar (L5) vertebrae were measured, and bone models consisting of the cancellous and cortical bones made from polyurethane foam were created. PS with diameters of 4.5 mm, 5.5 mm, and 6.5 mm were used. T1 PS were 25 mm long, and L4 and L5 PS were 40 mm long. The bone models were secured with cement, and the MIT was measured using a calibrated torque wrench. After MIT testing, the PS head was attached to the machine’s crosshead. POS was then calculated at a crosshead speed of 5 mm/min until failure.
Results:
The L4 and L5 were notably larger in female bone models, whereas the T1 vertebra was larger in male bone models. Consequently, the MIT and POS for L4 and L5 were higher in female bone models across all PS diameters than in male bone models. Conversely, the MIT for T1 was higher in male bone models across all PS; however, no significant differences were observed in the POS values for T1 between sexes.
Conclusions
The mechanical properties of the proposed bone models can vary based on the vertebral structure and size. For accurate 3D surgical and mechanical simulations in the creation of custom-made medical devices, bone models must be constructed from patientspecific medical images.
10.Patient-specific mechanical analysis of pedicle screw insertion in simulated osteoporotic spinal bone models derived from medical images
Norihiro NISHIDA ; Hidenori SUZUKI ; Hanvey TETSU ; Yuki MORISHITA ; Yogesh KUMARAN ; Fei JIANG ; Masahiro FUNABA ; Kazuhiro FUJIMOTO ; Yusuke ICHIHARA ; Takashi SAKAI ; Junji OHGI
Asian Spine Journal 2024;18(5):621-629
Methods:
Male and female patients with computed tomography data were selected. Dimensions of the first thoracic (T1), fourth lumbar (L4), and fifth lumbar (L5) vertebrae were measured, and bone models consisting of the cancellous and cortical bones made from polyurethane foam were created. PS with diameters of 4.5 mm, 5.5 mm, and 6.5 mm were used. T1 PS were 25 mm long, and L4 and L5 PS were 40 mm long. The bone models were secured with cement, and the MIT was measured using a calibrated torque wrench. After MIT testing, the PS head was attached to the machine’s crosshead. POS was then calculated at a crosshead speed of 5 mm/min until failure.
Results:
The L4 and L5 were notably larger in female bone models, whereas the T1 vertebra was larger in male bone models. Consequently, the MIT and POS for L4 and L5 were higher in female bone models across all PS diameters than in male bone models. Conversely, the MIT for T1 was higher in male bone models across all PS; however, no significant differences were observed in the POS values for T1 between sexes.
Conclusions
The mechanical properties of the proposed bone models can vary based on the vertebral structure and size. For accurate 3D surgical and mechanical simulations in the creation of custom-made medical devices, bone models must be constructed from patientspecific medical images.