1.Acu-Loc(R)2 volar distal radius bone plate system for repairing type C fracture of distal radius
Qunqun CHEN ; Rongqin QIAO ; Ruiqi DUAN ; Nianhong HU ; Zhao LI ; Min SHAO
Chinese Journal of Tissue Engineering Research 2017;21(7):1025-1030
BACKGROUND:Distal radius C fractures belong to multiple fractures in the joint. Its treatment should recover various angles and joint surface continuity outside the joint. The recovery of palmar tilt angle, radial inclination angle and radial height is also very important for treating distal radius. OBJECTIVE:To study the changes in palmar tilt angle, radial inclination angle and radial height after type C fractures of the distal radius repaired with Acu-Loc(R)2 VDR bone plate system. METHODS:From May 2015 to March 2016, 11 cases of type C distal radial fractures were treated with Acu-Loc(R)2 VDR bone plate system. Preoperatively, the palmar tilt angle was-31° to-4° (-12.45° on average), and the radial inclination angle was 6° to 18° (11.18° on average), and the radial height was 1.92 mm to 8.68 mm (5.28 mm on average). X-ray films were observed at postoperative 4, 8 and 12 weeks and half a year in all patients. Palmar tilt angle, radial inclination angle and radial height were measured and observed using anteroposterior and lateral X-ray films during final follow-up. Wrist function was assessed with Gartland-Werley score. RESULTS AND CONCLUSION:(1) 11 patients were followed and the postoperative follow-up ranged from 7 months to 15 months. X-ray films showed that the union of fractures was achieved in 6-8 weeks (6.5 weeks on average). No infection or internal fixation failure occurred. The articular facets were smooth in 10 patients and a little poor was found in 1 case (<2 mm). (2) After operation, the palmar tilt angle was 8° to 15° (11.55° on average) (P<0.05);the radial inclination angle was 22° to 27° (23.18° on average) (P<0.05);the radial height was 8.01 mm to 13 mm (11.03 mm on average) (P<0.05). (3) The results were excellent in 8 cases, good in 2 cases, and poor in 1 cases according to Gartland-Werley wrist function assessment;the excellent and good rate was 91%. (4) Acu-Loc(R)2 VDR bone plate fixation can provide reliable fixation and effective support for type C distal radius fractures, which can recover the palmar tilt angle, the radial inclination angle and the radial height, so the Acu-Loc(R)2 VDR bone plate is an ideal method to treat type C fractures of the distal radius.
2.Effects of early application of Tuina treatment on quadriceps surface myoelectricity in patients after total knee arthroplasty: a randomized controlled trial.
Nianhong WANG ; Juntao YAN ; Wuquan SUN ; Yongshan HU ; Jun XIA ; Licheng WEI ; Jie JIA ; Guilin OUYANG ; Yong HE ; Yanming GUO ; Jie XU
Journal of Integrative Medicine 2012;10(11):1247-53
Total knee replacement surgery is commonly used in end-stage diseases of the knee. It is important for improving surgical efficacy and patient satisfaction by promoting early rehabilitation of patients and improving knee function.
3.Study of Extracts from Bushen Huoxue Decoction in Promoting Proliferation of Rat Bone Marrow Mesenchymal Stem Cells
Yongquan HUANG ; Yiwen LUO ; Bin WANG ; Nianhong HU ; Dongfeng CHEN ; Xunchao ZHANG ; Yan CAI ; Wangyang LI ; Mincong HE ; Qiuke HOU ; Zhiming XU ; Yamei LIU
Journal of Guangzhou University of Traditional Chinese Medicine 2015;(1):86-91
Objective To screen the active components of Bushen Huoxue Decoction ( BSHXD) involved in promoting the proliferation of bone marrow mesenchymal stem cells ( MSCs). Methods BSHXD and its subdivisions were extracted with petroleum ether, ethyl acetate, water-free ethanol and water respectively. MSCs were isolated and cultured by the bone marrow adherent method. At the third passage, MSCs were identified by the specific surface markers with immunofluorescence, and their osteogenic and adipogenic differentiation were tested by alizarin red staining and oil red “O” staining. After treated with the extracts of BSHXD and its subdivisions at gradient concentrations for 24 hours, cell viability was detected by methyl thiazolyl tetrazolium (MTT) assay for the screening of active components and optimal concentration. MTT assay was used to describe the growth curve of MSCs treated with the most effective components, and cell cycle was analyzed by flow cytometry. Results Compared with the blank control group, the extracts of BSHXD and its subdivisions could protect MSCs from death to various degrees. Of all the extracts, the ethyl acetate extract of Bushen Division ( BSD) , ethyl acetate extract of BSHXD, ethyl acetate extract of Huoxue Division ( HXD) had the strongest effect, and the effect was dose-dependent, 100 μg/mL being the optimal active concentration while having no any cytotoxic reaction. The results of MTT assay revealed that BSD extracts promoted the proliferation of MSCs significantly and was the most effective component, and then came BSHXD. The results of flow cytometry indicated that BSD extract had the most strongest effect on increasing the amount of MSCs at proliferative phase, and then came BSHXD. Conclusion BSD ethyl acetate extract is the active component of BSHXD for promoting the proliferation of MSCs, showing an effect on increasing the proportion of MSCs at proliferative phase.
4.Application of fingerprint recognition technology in identification and management of mental patients
Bin XU ; Xuefeng SHEN ; Yiping QIAN ; Nianhong SHEN ; Xiaofeng HU
Chinese Journal of Modern Nursing 2014;20(32):4143-4145
Objective To investigate the effect of using fingerprint identification instrument on the identity management quality and satisfaction of patients.Methods The relevant information of mental patients was inputted by portable fingerprint machine at the time of admission.It was unneeded for providing information from patients or their family members in various nursing operation.The patients’ ID information could directly confirmed through fingerprint comparison.Mental patients compliance rate, defect rate, wrist strap material cost saving rate, nursing staff satisfaction on identity recognition were compared before and after the using of fingerprint identification.Results Before the using of fingerprint identification instrument, psychiatric patients on identity compliance rate was 82%, defect rate was 36%,wrist strap material cost saving rate was 5%, and nursing staff satisfaction on identity recognition was 86%; while there were 98%,6%,45%,99% after, and the differences were statistically significant (χ2 =7.11,13.56,21.00,46.89,respectively;P<0.05).Conclusions Fingerprint identification system can improve the compliance of psychiatic patients identity recognition, reduce the defect identification rate, save costs and improve nursing satisfaction, and improve the mental patient identity management quality.
5.Comparison of different identification application in identity management of patients with mental disorder
Bin? XU ; Yiping QIAN ; Nianhong SHEN ; Xiaofeng HU
Chinese Journal of Modern Nursing 2015;(26):3198-3199,3200
Objective To explore the effects of different identity identification methods in the quality of clinical nursing management of psychosis patients. Methods By the conventional recognition, wristband identification, fingerprint identification, we compared the different identification correct rate, compliance rate, defect rate, wristband material cost saving rates, satisfaction of identification for mental patients before and after the identification. Results The rate of correct identification for patients with different identification were respectively 95. 60%, 99%, 100% with statistical significance (χ2 =62. 58,P<0. 05). After several correct rate of identification comparison, there were statistically significant differences in any two of three groups (χ2 =25. 42,44. 99, 10. 06;P<0. 01). Before and after the use of fingerprint identification instrument, the mental patients to identity compliance rates were 82% and 98% (χ2 =45. 81,P<0. 05); defect identification rates were 36% and 6% (χ2 =282. 74,P<0. 05);wrist strap material cost saving rates were 5% and 45% (χ2 =490. 08,P<0. 05);satisfaction with the way of identifying rates were 86% and 99% (χ2 =10. 07,P<0. 05). Conclusions Patients with different identification have different identity recognition correct rate. Wristband helps us improve the accuracy of identification, while the fingerprint identification device have the highest correct rate to indentify mental patients to without limitation use in Psychiatry Department by improving the psychiatric nursing compliance of both patient and medical staffs identification, reducing the defect identification rate, saving manpower and material costs and improving both nurses and patients satisfaction rate.