1.The value of endeavour ultrasound with dobutamin in diagnosing ischemic heart disease
Journal of Practical Medicine 2003;466(11):6-12
From 1997 July to 2003 April at Hospital 108, the study was carried out on 90 patients suspected of ischemia with chest pain or on ECG. Ultrasound dobutamin stress test was undertaken with infused initial doses of 5mcg/kg/min until reaching an expected heart rate depending on the ages. Results showed that ultrasound dobutamin stresst test is a diagnostic method of 96% of sensitivity, 84% of specificity and 91% of accuracy
Myocardial Ischemia
;
ultrasonography
;
Heart Diseases
2.The value of endeavour ultrasound with dobutamin in diagnosis ischemic heart disease
Journal of Practical Medicine 2003;466(11):33-38
Dobutamin stress test with echocardiography was performed on 90 suspected patients of heart ischemia, aged 59.6 9.5 years old, during 29.1 17.49 months of following from July 1997 to April 2003 at the Hospital N0108. Results showed that, the procedure reach a sensitivity of 96%, specificity of 84% and an accuracy of 91%
Ultrasonography
;
Myocardial Ischemia
;
Heart Diseases
3.Value of quantitative tissue velocity imaging in the detection of regional myocardial function in dogs with acute subendocardial ischemia.
Qinyyang, ZHANG ; Youbin, DENG ; Yani, LIU ; Haoyi, YANG ; Bingbing, LIU ; Weihui, SHENTU ; Peng, LI
Journal of Huazhong University of Science and Technology (Medical Sciences) 2008;28(6):727-31
This study evaluated the application of quantitative tissue velocity imaging (QTVI) in assessing regional myocardial systolic and diastolic functions in dogs with acute subendocardial ischemia. Animal models of subendocardial ischemia were established by injecting microspheres (about 300 microm in diameter) into the proximal end of left circumflex coronary artery in 11 hybrid dogs through cannulation. Before and after embolization, two-dimensional echocardiography, QTVI and real-time myocardial contrast echocardiography (RT-MCE) via intravenous infusion of self-made microbubbles, were performed, respectively. The systolic segmental wall thickening and subendocardial myocardial longitudinal velocities of risk segments before and after embolization were compared by using paired t analysis. The regional myocardial video intensity versus contrast time could be fitted to an exponential function: y=A.(1-exp(-beta.t)), in which the product of A and beta provides a measure of myocardial blood flow. RT-MCE showed that subendocardial normalized A.beta was decreased markedly from 0.99+/-0.19 to 0.35+/-0.11 (P<0.05) in 28 left ventricular (LV) myocardial segments after embolization, including 6 basal and 9 middle segments of lateral wall (LW), 8 middle segments of posterior wall (PW) and 5 middle segments of inferior wall (IW). However, there was no statistically significant difference in subepicardial layer before and after embolization. Accordingly, the ratio of A.beta of subendocardial myocardium to subepicardial myocardium in these segments was significantly decreased from 1.10+/-0.10 to 0.31+/-0.07 (P<0.05). Although the systolic wall thickening did not change 5 min after the embolization in these ischemic segments (29%+/-3% vs 31%+/-5%, P>0.05), the longitudinal peak systolic velocities (Vs) and early-diastolic peak velocities (Ve) recorded by QTVI were declined significantly (P<0.05). Moreover, the subendocardial velocity curves during isovolumic relaxation predominantly showed positive waves, whereas they mainly showed negative waves before the embolization. This study demonstrates that QTVI can more sensitively and accurately detect abnormal regional myocardial function and post-systolic systole caused by acute subendocardial ischemia.
Contrast Media
;
Echocardiography/*methods
;
Endocardium/physiopathology
;
Microbubbles
;
Myocardial Contraction/physiology
;
Myocardial Ischemia/etiology
;
Myocardial Ischemia/*physiopathology
;
Myocardial Ischemia/*ultrasonography
;
Myocardium/pathology
;
Ventricular Function, Left/*physiology
4.Anomalous Origin of a Right Coronary Artery With Extrinsic Compression Between the Great Vessels: The Intravascular Ultrasound Images.
Jae Youn MOON ; Hae Chang JEONG ; Jae Yeong CHO ; Doo Sun SIM ; Hyung Wook PARK ; Young Joon HONG ; Ju Han KIM ; Young Keun AHN ; Myung Ho JEONG
Korean Circulation Journal 2008;38(7):390-392
The anomalous origin of the right coronary artery is a rare condition, but it has clinical importance because there have been reports of nonfatal or fatal myocardial infarction and sudden death associated with exercise for patients with this anatomy. We describe here a patient for whom 64 channel multi-detector row computed tomography was useful to identify this anomaly, and intravascular ultrasound was used to evaluate the myocardial ischemia by visualizing the coronary lumen.
Coronary Vessels
;
Death, Sudden
;
Humans
;
Myocardial Infarction
;
Myocardial Ischemia
;
Ultrasonography, Interventional
5.Spontaneous Coronary Artery Dissection Manifested during Ergonovine Test and Treated with Intravascular Ultrasound Guided Stenting: A Case Report.
Sung Gyun AHN ; Seung Jea TAHK ; Jung Hyun CHOI ; Sang Yong YOO ; Zhen Guo ZHENG ; Byoung Joo CHOI ; Tae Young CHOI ; So Yeon CHOI ; Myeong Ho YOON ; Gyo Seung HWANG ; Joon Han SHIN
Korean Circulation Journal 2005;35(3):264-268
Spontaneous coronary artery dissection (SCAD) is an uncommon cause of acute myocardial ischemia, which frequently presents as sudden death. The pathophysiology and treatment of SCAD have not been fully determined. Herein, a case of SCAD, manifesting as variant angina, which rapidly progressed during an ergonovine test, in which 3 drug-eluting stents were deployed using intravascular an ultrasound guidance, with an excellent immediate result, is reported.
Coronary Vessels*
;
Death, Sudden
;
Drug-Eluting Stents
;
Ergonovine*
;
Myocardial Ischemia
;
Stents*
;
Ultrasonography*
;
Ultrasonography, Interventional
6.Ischemia-based Coronary Revascularization: Beyond Anatomy and Fractional Flow Reserve
Hong Seok LIM ; Kyoung Woo SEO ; Myeong Ho YOON ; Hyoung Mo YANG ; Seung Jea TAHK
Korean Circulation Journal 2018;48(1):16-23
Treatment strategies for patients with coronary artery disease (CAD) should be based on objective evidence of inducible ischemia in the subtended myocardium to improve clinical outcomes, symptoms, and cost-effectiveness. Fractional flow reserve (FFR) is the most verified index to-date for invasively evaluating lesion-specific myocardial ischemia. Favorable results from large clinical trials that applied FFR-guided percutaneous coronary intervention (PCI) prompted changes in coronary revascularization guidelines to emphasize the importance of this ischemia-based strategy using invasive coronary physiology. However, the frequency of functional evaluations is lacking in daily practice, and visual assessment still dominates treatment decisions in CAD patients. Despite recent efforts to integrate functional and anatomical assessments for coronary stenosis, there is considerable discordance between the 2 modalities, and the diagnostic accuracy of simple parameters obtained from current imaging tools is not satisfactory to determine functional significance. Although evidence that supports or justifies anatomy-guided PCI is more limited, and FFR-guided PCI is currently recommended, it is important to be aware of conditions and factors that influence FFR for accurate interpretation and application. In this article, we review the limitations of the current anatomy-derived evaluation of the functional significance of coronary stenosis, detail considerations for the clinical utility of FFR, and discuss the importance of an integrated physiologic approach to determine treatment strategies for CAD patients.
Coronary Angiography
;
Coronary Artery Disease
;
Coronary Stenosis
;
Humans
;
Ischemia
;
Myocardial Ischemia
;
Myocardium
;
Percutaneous Coronary Intervention
;
Physiology
;
Ultrasonography, Interventional
7.A Totally Occluded Long Segment Myocardial Bridge: 10-year Follow-up after Percutaneous Coronary Intervention in a Patient with Hypertrophic Cardiomyopathy.
Hyun Kuk KIM ; Myung Ho JEONG ; Minah KIM ; Youngkeun AHN ; Jeong Gwan CHO ; Jong Chun PARK
Korean Journal of Medicine 2016;90(6):533-536
Intracoronary stent implantation can improve coronary hemodynamics and myocardial ischemia in patients with symptomatic bridging. However, percutaneous coronary intervention for this lesion is limited due to the high prevalence of restenosis and risk of complications. We present a case of a totally occluded long-segment myocardial bridge in a patient with hypertrophic cardiomyopathy who was successfully implanted with a bare metal stent under intravascular ultrasound guidance without complications. The patient has been free of ischemic symptoms with stent patency for 10 years.
Cardiomyopathy, Hypertrophic*
;
Follow-Up Studies*
;
Hemodynamics
;
Humans
;
Myocardial Bridging
;
Myocardial Ischemia
;
Percutaneous Coronary Intervention*
;
Prevalence
;
Stents
;
Ultrasonography
8.Positive Peri-Stent Vascular Remodeling and Late-Acquired Incomplete Stent Apposition in Intravascular Ultrasound (IVUS) after Drug-Eluting Stent Implantation.
Hyo Eun KIM ; Seung Ho HUR ; Kwon Bae KIM ; Yoon Nyun KIM ; Seongwook HAN ; Hyungseop KIM ; Hyuck Jun YOON ; Yun Kyeong CHO ; Ki Bum WON ; In Cheol KIM
Keimyung Medical Journal 2015;34(1):1-13
The peri-stent vascular changes after 2nd generation drug-eluting stent (2G DES) implantation have not been fully investigated compare to 1st generation DES (1G DES). From March 2003 to October 2010, patients receiving percutaneous coronary intervention (PCI) with either 1G or 2G DES were retrospectively included. All patients underwent intravascular ultrasound (IVUS) at post-procedure and 8-12 months after PCI. A total of 281 patients (1G DES: 201 patients with 217 lesions and 2G DES: 80 patients with 88 lesions) were enrolled. The incidence of positive peri-stent vascular remodeling (PPVR) and late-acquired incomplete stent apposition (LAISA) were investigated by IVUS images. Major adverse cardiac events (MACE) up to 3 years were also evaluated. The lesion and the stent length were shorter, and the stent size was larger in the 2G DES group. The incidences of PPVR and LAISA were lower in the 2G DES group before and after propensity score matching. However, the incidence of 3-year MACE were not different between the two groups. Independent predictors for PPVR or LAISA were stent length and 1G DES implantation. These results suggested that biocompatible stent system in 2G DES might have reduced peri-stent vascular changes.
Drug-Eluting Stents*
;
Humans
;
Incidence
;
Myocardial Ischemia
;
Percutaneous Coronary Intervention
;
Propensity Score
;
Retrospective Studies
;
Stents*
;
Ultrasonography*
9.Clinical observation of aortic dissection.
Byeong Ik JANG ; Jin Ho PARK ; Dong Ku SHIN ; Yeoung Jo KIM ; Bong Sup SHIM ; Hyun Woo LEE ; Su Hyen KIM ; Sung Sae HAN
Yeungnam University Journal of Medicine 1992;9(2):334-341
A clinical review of 34 cases of aortic dissection which were admitted to Yeungnam University hospital between March 1983 and April 1992. The results are as follows: 1. The peak incidence was in 5th, 6th decade and male to female ratio was 1.83:1. 2. The most common cause of aortic dissection was atherosclerosis and hypertension (79%). 3. The most common presenting symptom was pain (73%). but dyspnea, palpable mass, murmur, shock were also observed. 4. Abnormal electrocardiographic finding was myocardial ischemia in 6 cases, arrhythmia in 5 cases, LVH in 5 cases. 5. The X-ray findings showed abnormal aortic contour in 10 cases but normal X-ray finding was observed in 63% of DeBaKey Type III. 6. The most common diagnostic procedure was echocardiogram and abdominal Ultrasonography. 7. The mortality of all cases was 20%, operation mortality was 18% but no death of medically treatment in medical indication.
Arrhythmias, Cardiac
;
Atherosclerosis
;
Dyspnea
;
Electrocardiography
;
Female
;
Humans
;
Hypertension
;
Incidence
;
Male
;
Mortality
;
Myocardial Ischemia
;
Shock
;
Ultrasonography
10.Second Harmonic Imaging Myocardial Contrast 2D Echocardiography before and after Left Anterior Descending Coronary Artery Ligation.
Sang Man CHUNG ; Navin C NANDA ; Ashutosh DWIVEDI ; Wan KIM
Korean Circulation Journal 1997;27(12):1328-1335
BACKGROUND: Although myocardial contrast 2D echocardiography is a good method to diagnose and evaluate myocardial ischemia and reperfusion, it has required intracoronary or intra aortic root injection of contrast agent and furthemore, the degree of myocardial contrast produced is small. Second harmonic imaging which is based on the non linear emission of harmonics by resonant microbubble in the ultrasound field improves the ultrasound contrast single to noise ratio. METHODS: We measure the videointensity of interventricular septum(IVS) and lateral wall(LW) of second harmonic imaging myocardial contrast 2D echocardiography before and after LV injection of Levovist(300mg/ml, 0.4ml/Kg) in both pre and post left anterior descending coronary artery(LAD) ligation in 7 open chest pigs. RESULTS: 1) The mean(+/-SD) pre LAD ligation videointensity is significantly greater with after contrast than before contrast(IVS : 111.1+/-33.9 vs 31.1+/-7.6 ; p=0.00046, LW : 120.5+/-21.5 vs 42.2+/-10.0 ; p=0.00006). The post LAD ligation videointensity is also significantly greater with after contrast than before contrast(IVS : 62.8+/-24.6 vs 35.6+/-15.1 ; p=0.00379, LW : 129.9+/-10.9 vs 48.7+/-21.1 ; p=0.00006). 2) The videointensity of IVS is significantly greater with after contrast than before contrast in both pre and post LAD ligation(62.8+/-24.6 vs 111.1+/-33.9 ; p=0.0031). The post LAD ligation videointensity of LW after contrast is not different from that of pre LAD ligation(129.9+/-10.9 vs 120.5+/-21.5 ; p=0.1037). 3) The post LAD ligation videointensity increase of IVS is lower than pre LAD ligantion videointensity increase(27.2+/-18.3 vs 79.9+/-35.0 ; p=0.0006). But the videointensity increase of LW is not different between pre and post LAD ligation(78.2+/-23.4 vs 81.2+/-24.5 ; p=0.3778). CONCLUSION: These findings indicate that the myocardial blood flow and its decrease due to LAD ligation can be evaluated accurately by second harmonic imaging myocardial contrast 2D echocardiography.
Coronary Vessels*
;
Echocardiography*
;
Ligation*
;
Microbubbles
;
Myocardial Ischemia
;
Noise
;
Reperfusion
;
Swine
;
Thorax
;
Ultrasonography