1.Current application status of stem cell therapy in the field of lung transplantation
Mingyu GU ; Xiangyun ZHENG ; Ji’er MA ; Xiaohan JIN ; Zhiqiang DENG ; Haoji YAN ; Dong TIAN
Organ Transplantation 2026;17(2):311-318
In recent years, research on stem cell therapy in the field of lung transplantation has gradually increased, demonstrating its potential in improving the outcomes of lung transplantation. As a treatment option for end-stage lung diseases, lung transplantation faces challenges such as scarcity of donor organs, postoperative complications and rejection. Stem cells, with their self-renewal and multi-directional differentiation capabilities, have emerged as strong candidates for alternative or adjunctive treatments. Current studies show that embryonic stem cells and umbilical cord mesenchymal stem cells play significant roles in lung tissue regeneration and immune regulation. However, stem cell therapy still needs to overcome issues such as the selection of cell sources, low survival rates after transplantation and unclear long-term efficacy in clinical applications. Future research should focus on exploring new stem cell sources, improving transplantation techniques and establishing efficacy evaluation systems.
2.New quality productive forces promote the surgical treatment and device innovation of gas-trointestinal cancer
Ruijing SHEN ; Yitong TIAN ; Xueyin ZHOU ; Tian'ao XIE ; Mingyu CHEN
Chinese Journal of Digestive Surgery 2025;24(4):501-506
The profound integration of novel qualitative productive forces throughout the entire process of diagnosing and treating gastrointestinal cancer has catalyzed innovative advance-ments in surgical techniques and postoperative rehabilitation. In the field of minimally invasive resection, technological innovations, from laparoscopic surgery to robot-assisted surgical systems that transcend traditional visual and operational limitations, and further to the integration of artificial intelligence and 5G technologies that overcome spatiotemporal barriers for real-time decision-making and telemedicine, have significantly enhanced the precision and safety of gastrointestinal tumor surgery. Concurrently, the development of innovative medical devices plays a pivotal role in improving perioperative and postoperative rehabilitation efficiency. Functional device design focuses on addressing the holistic needs of patients throughout their clinical journey, systematically resolving efficiency and safety bottlenecks inherent in conventional diagnostic and therapeutic approaches. Technological progress has further enabled non-invasive, convenient remote health management for patients. Novel qualitative productive forces not only redefine surgical paradigms but also deliver efficient, safe, and patient-centered diagnostic and therapeutic experiences through comprehensive innovation across all treatment phases. This evolution marks a critical breakthrough in modern medicine's transition toward intelligence and systematization, heralding a new era of intelligent healthcare delivery.
3.Propensity score-matched comparison of short-term outcomes between robotic-assisted and laparoscopic radical resection for biliary tract cancers
Qingyang RUAN ; Xueyin ZHOU ; Tian LEI ; Yitong TIAN ; Ruijing SHEN ; Mingyu CHEN
Chinese Journal of General Surgery 2025;34(8):1648-1661
Background and Aims:Biliary tract cancers(BTCs)are highly aggressive malignancies with dismal prognosis,for which radical resection remains the only potentially curative treatment.Laparoscopic surgery has demonstrated superiority over open surgery in perioperative safety and recovery,yet it is technically limited in complex operations.Robot-assisted laparoscopy,with its high-definition three-dimensional vision and enhanced instrument dexterity,may overcome these limitations.However,comparative evidence balancing baseline differences between laparoscopic and robot-assisted laparoscopic radical resections for BTCs is still lacking.This study aimed to evaluate and compare their short-term safety using propensity score matching(PSM).Methods:A total of 151 patients with biliary tract cancers who underwent radical resection were retrospectively enrolled from the Chinese Biliary Tract Tumor Collaborative Group database,including 128 in the laparoscopic group and 23 in the robotic-assisted laparoscopic group.To balance baseline differences,an initial 1∶1 PSM was performed,yielding 19 laparoscopic and 19 robotic cases.Subsequently,using the robotic group as the reference,a 1∶2 PSM was conducted,resulting in 36 laparoscopic and 18 robotic cases.Primary outcomes(conversion to open surgery,ICU admission,and postoperative complications)and secondary outcomes(operative time,intraoperative blood loss,transfusion,postoperative hospital stay,reoperation,readmission,and hospitalization costs)were compared between the two groups.Multivariate regression analyses were performed to explore factors associated with conversion to open surgery and postoperative hospital stay.Results:After matching,baseline characteristics were well balanced between groups.For primary outcomes,the conversion rate to open surgery was significantly higher in the laparoscopic group than in the robotic group(41.7%vs.0,P=0.001),while ICU admission,overall postoperative complications,and Clavien-Dindo graded complications showed no significant differences(all P>0.05).For secondary outcomes,the postoperative hospital stay was significantly more extended in the laparoscopic group compared with the robotic group(18.5 d vs.8.0 d,P=0.005),whereas operative time,intraoperative blood loss,transfusion,reoperation,readmission,and hospitalization costs were comparable(all P>0.05).Logistic regression for conversion did not identify statistically significant predictors,but moderately differentiated tumors,elevated preoperative CA19-9,and higher harvested lymph node counts showed trends toward increased risk.Multivariate linear regression revealed that robotic-assisted surgery was an independent factor for reduced postoperative hospital stay(P=0.024),while preoperative total bilirubin(P=0.020),longer operative time(P=0.000),postoperative complications(P=0.006),and reoperation(P=0.005)were found to be associated with a prolonged hospital stay.Conclusion:Robot-assisted laparoscopic radical resection for BTCs is not inferior to conventional laparoscopy in short-term safety and may further reduce conversion rates and hospital stay.Its technical advantages may be particularly valuable in anatomically complex or challenging cases.Nonetheless,cost-effectiveness and resource allocation should be considered for wider adoption.
4.Propensity score-matched comparison of short-term outcomes between robotic-assisted and laparoscopic radical resection for biliary tract cancers
Qingyang RUAN ; Xueyin ZHOU ; Tian LEI ; Yitong TIAN ; Ruijing SHEN ; Mingyu CHEN
Chinese Journal of General Surgery 2025;34(8):1648-1661
Background and Aims:Biliary tract cancers(BTCs)are highly aggressive malignancies with dismal prognosis,for which radical resection remains the only potentially curative treatment.Laparoscopic surgery has demonstrated superiority over open surgery in perioperative safety and recovery,yet it is technically limited in complex operations.Robot-assisted laparoscopy,with its high-definition three-dimensional vision and enhanced instrument dexterity,may overcome these limitations.However,comparative evidence balancing baseline differences between laparoscopic and robot-assisted laparoscopic radical resections for BTCs is still lacking.This study aimed to evaluate and compare their short-term safety using propensity score matching(PSM).Methods:A total of 151 patients with biliary tract cancers who underwent radical resection were retrospectively enrolled from the Chinese Biliary Tract Tumor Collaborative Group database,including 128 in the laparoscopic group and 23 in the robotic-assisted laparoscopic group.To balance baseline differences,an initial 1∶1 PSM was performed,yielding 19 laparoscopic and 19 robotic cases.Subsequently,using the robotic group as the reference,a 1∶2 PSM was conducted,resulting in 36 laparoscopic and 18 robotic cases.Primary outcomes(conversion to open surgery,ICU admission,and postoperative complications)and secondary outcomes(operative time,intraoperative blood loss,transfusion,postoperative hospital stay,reoperation,readmission,and hospitalization costs)were compared between the two groups.Multivariate regression analyses were performed to explore factors associated with conversion to open surgery and postoperative hospital stay.Results:After matching,baseline characteristics were well balanced between groups.For primary outcomes,the conversion rate to open surgery was significantly higher in the laparoscopic group than in the robotic group(41.7%vs.0,P=0.001),while ICU admission,overall postoperative complications,and Clavien-Dindo graded complications showed no significant differences(all P>0.05).For secondary outcomes,the postoperative hospital stay was significantly more extended in the laparoscopic group compared with the robotic group(18.5 d vs.8.0 d,P=0.005),whereas operative time,intraoperative blood loss,transfusion,reoperation,readmission,and hospitalization costs were comparable(all P>0.05).Logistic regression for conversion did not identify statistically significant predictors,but moderately differentiated tumors,elevated preoperative CA19-9,and higher harvested lymph node counts showed trends toward increased risk.Multivariate linear regression revealed that robotic-assisted surgery was an independent factor for reduced postoperative hospital stay(P=0.024),while preoperative total bilirubin(P=0.020),longer operative time(P=0.000),postoperative complications(P=0.006),and reoperation(P=0.005)were found to be associated with a prolonged hospital stay.Conclusion:Robot-assisted laparoscopic radical resection for BTCs is not inferior to conventional laparoscopy in short-term safety and may further reduce conversion rates and hospital stay.Its technical advantages may be particularly valuable in anatomically complex or challenging cases.Nonetheless,cost-effectiveness and resource allocation should be considered for wider adoption.
5.Expression and clinical significance of lysosome-associated membrane protein 3 and activating transcription factor 4 in cervical cancer
Yayue WANG ; Xiaona LUAN ; Xiaohan CHEN ; Huihui MA ; Mingyu LI ; Tian TIAN
Chinese Journal of Cancer Biotherapy 2025;32(5):518-524
Objective:To investigate the expression of lysosome-associated membrane protein 3(LAMP3)and activating transcription factor 4(ATF4)in cervical cancer and their correlation with clinicopathological parameters.Methods:The expression of LAMP3 and ATF4 in normal cervical tissues,cervical intraepithelial lesions,and cervical cancer tissues was detected by SP immunohistochemistry.The relationships between the expression of these two proteins and patient clinicopathological parameters were analyzed,as well as the correlation between LAMP3 and ATF4 expression.Results:LAMP3 was negative or lowly expressed in both normal cervix tissues and high-grade squamous intraepithelial lesions,but highly expressed in cervical cancer tissues(38.3%),showing a statistically significant difference(χ2=14.113,P=0.001).ATF4 was highly expressed in 26.7%of the normal cervix tissues,10.0%of the high-grade squamous intraepithelial lesions,and 58.3%in the cervical cancer tissues,also showing a significant difference(χ2=11.078,P=0.004).In cervical cancer,LAMP3 expression was significantly associated with FIGO stage(χ2=10.139,P=0.006)and lymph node metastasis(χ2=8.475,P=0.004);ATF4 expression was significantly associated with tumor size(χ2=4.578,P=0.032),FIGO stage(χ2=8.971,P=0.009),and lymph node metastasis(χ2=7.881,P=0.005).There was a positive correlation between the expression of LAMP3 and ATF4 in cervical cancer tissues(r=0.388,P=0.002).Conclusion:LAMP3 and ATF4 are highly expressed in cervical cancer tissues and are positively correlated.Both of them play important roles in the development and progression of cervical cancer and could serve as potential therapeutic targets for cervical cancer treatment.
6.Analysis of the safety and efficacy of transcatheter mitral valve-in-valve replacement for the bioprosthetic mitral valve failure
Shulin NIU ; Zhouming WANG ; Mingyu LIU ; Xin GUAN ; Mengqi LI ; Yikui TIAN ; Zhenwen YANG ; Xin DU
Tianjin Medical Journal 2025;53(9):993-999
Objective To evaluate the safety and efficacy of transcatheter mitral valve-in-valve replacement(ViV-TMVR)in the treatment of bioprosthetic mitral valve failure.Methods Seventeen patients with bioprosthetic mitral valve failure who required ViV-TMVR were selected.Preoperative data including age,gender,body mass index(BMI),usage time of bioprosthetic mitral valve,comorbidities(hypertension,coronary heart disease,old cerebral infarction,atrial fibrillation and diabetes)and New York Heart Association(NYHA)functional class were recorded,and left ventricular end-diastolic diameter(LVEDD),right atrial diameter(RA),pulmonary artery systolic pressure(PASP),left ventricular ejection fraction(LVEF),type of bioprosthetic mitral valve failure,degree of bioprosthetic mitral valve regurgitation and stenosis,peak velocity and mean transvalvular pressure gradient of the bioprosthetic mitral valve,and Society of Thoracic Surgeons(STS)score were also collected.Intraoperative data included puncture route,valve type,intraoperative complications,operation time and immediate postoperative transesophageal echocardiography(TEE)assessment(peak velocity and mean transvalvular pressure gradient of the valve-in-valve,valve-in-valve regurgitation or paravalvular regurgitation)were collected.Postoperative data included time in the intensive care unit(ICU)/cardiovascular intensive care unit(CCU),total postoperative hospital stay and 30-day postoperative echocardiographic results and NYHA functional class were recorded.Patients were divided into the domestic NewMed valve group(10 cases)and the imported Edwards valve group(7 cases)based on the type of valve used.The safety and efficacy of ViV-TMVR were analyzed,and the efficacy of domestic valves and imported valves was compared.Results All 17 patients successfully underwent ViV-TMVR via the transseptal approach without serious complications,and the 30-day readmission rate was 0%.There were no significant differences in operation time of domestic valves and imported valves,mild paravalvular regurgitation of the valve-in-valve,peak velocity and mean transvalvular pressure gradient of the valve-in-valve immediately after surgery and at 30-day postoperatively,time in ICU/CCU,total postoperative hospital stay and the proportion of patients with NYHA functional class Ⅲ-Ⅳ at 30-day postoperatively between the domestic valve group and the imported valve group.During the 30-day follow-up,one patient died of cerebral hemorrhage,and one patient had major adverse cardiovascular events(MACE,cerebral hemorrhage).Compared with before the operation,the peak velocity and mean transvalvular pressure gradient of the valve-in-valve,LVEF,and PASP decreased immediately after surgery and at 30 days after surgery.Compared with immediately after surgery,the peak velocity and mean transvalvular pressure gradient of the valve-in-valve increased at 30 days postoperatively(P<0.01),while there were no significant differences in LVEF and PASP.Conclusion Transseptal ViV-TMVR is safe and effective in the short term for patients with bioprosthetic mitral valve failure who are at high risk of re-thoracotomy,and the efficacy of domestic valves is comparable to that of imported valves.
7.Analysis of the safety and efficacy of transcatheter mitral valve-in-valve replacement for the bioprosthetic mitral valve failure
Shulin NIU ; Zhouming WANG ; Mingyu LIU ; Xin GUAN ; Mengqi LI ; Yikui TIAN ; Zhenwen YANG ; Xin DU
Tianjin Medical Journal 2025;53(9):993-999
Objective To evaluate the safety and efficacy of transcatheter mitral valve-in-valve replacement(ViV-TMVR)in the treatment of bioprosthetic mitral valve failure.Methods Seventeen patients with bioprosthetic mitral valve failure who required ViV-TMVR were selected.Preoperative data including age,gender,body mass index(BMI),usage time of bioprosthetic mitral valve,comorbidities(hypertension,coronary heart disease,old cerebral infarction,atrial fibrillation and diabetes)and New York Heart Association(NYHA)functional class were recorded,and left ventricular end-diastolic diameter(LVEDD),right atrial diameter(RA),pulmonary artery systolic pressure(PASP),left ventricular ejection fraction(LVEF),type of bioprosthetic mitral valve failure,degree of bioprosthetic mitral valve regurgitation and stenosis,peak velocity and mean transvalvular pressure gradient of the bioprosthetic mitral valve,and Society of Thoracic Surgeons(STS)score were also collected.Intraoperative data included puncture route,valve type,intraoperative complications,operation time and immediate postoperative transesophageal echocardiography(TEE)assessment(peak velocity and mean transvalvular pressure gradient of the valve-in-valve,valve-in-valve regurgitation or paravalvular regurgitation)were collected.Postoperative data included time in the intensive care unit(ICU)/cardiovascular intensive care unit(CCU),total postoperative hospital stay and 30-day postoperative echocardiographic results and NYHA functional class were recorded.Patients were divided into the domestic NewMed valve group(10 cases)and the imported Edwards valve group(7 cases)based on the type of valve used.The safety and efficacy of ViV-TMVR were analyzed,and the efficacy of domestic valves and imported valves was compared.Results All 17 patients successfully underwent ViV-TMVR via the transseptal approach without serious complications,and the 30-day readmission rate was 0%.There were no significant differences in operation time of domestic valves and imported valves,mild paravalvular regurgitation of the valve-in-valve,peak velocity and mean transvalvular pressure gradient of the valve-in-valve immediately after surgery and at 30-day postoperatively,time in ICU/CCU,total postoperative hospital stay and the proportion of patients with NYHA functional class Ⅲ-Ⅳ at 30-day postoperatively between the domestic valve group and the imported valve group.During the 30-day follow-up,one patient died of cerebral hemorrhage,and one patient had major adverse cardiovascular events(MACE,cerebral hemorrhage).Compared with before the operation,the peak velocity and mean transvalvular pressure gradient of the valve-in-valve,LVEF,and PASP decreased immediately after surgery and at 30 days after surgery.Compared with immediately after surgery,the peak velocity and mean transvalvular pressure gradient of the valve-in-valve increased at 30 days postoperatively(P<0.01),while there were no significant differences in LVEF and PASP.Conclusion Transseptal ViV-TMVR is safe and effective in the short term for patients with bioprosthetic mitral valve failure who are at high risk of re-thoracotomy,and the efficacy of domestic valves is comparable to that of imported valves.
8.New quality productive forces promote the surgical treatment and device innovation of gas-trointestinal cancer
Ruijing SHEN ; Yitong TIAN ; Xueyin ZHOU ; Tian'ao XIE ; Mingyu CHEN
Chinese Journal of Digestive Surgery 2025;24(4):501-506
The profound integration of novel qualitative productive forces throughout the entire process of diagnosing and treating gastrointestinal cancer has catalyzed innovative advance-ments in surgical techniques and postoperative rehabilitation. In the field of minimally invasive resection, technological innovations, from laparoscopic surgery to robot-assisted surgical systems that transcend traditional visual and operational limitations, and further to the integration of artificial intelligence and 5G technologies that overcome spatiotemporal barriers for real-time decision-making and telemedicine, have significantly enhanced the precision and safety of gastrointestinal tumor surgery. Concurrently, the development of innovative medical devices plays a pivotal role in improving perioperative and postoperative rehabilitation efficiency. Functional device design focuses on addressing the holistic needs of patients throughout their clinical journey, systematically resolving efficiency and safety bottlenecks inherent in conventional diagnostic and therapeutic approaches. Technological progress has further enabled non-invasive, convenient remote health management for patients. Novel qualitative productive forces not only redefine surgical paradigms but also deliver efficient, safe, and patient-centered diagnostic and therapeutic experiences through comprehensive innovation across all treatment phases. This evolution marks a critical breakthrough in modern medicine's transition toward intelligence and systematization, heralding a new era of intelligent healthcare delivery.
9.Mortality from cerebrovascular diseases in China: Exploration of recent and future trends
Bin LV ; Ge SONG ; Feng JING ; Mingyu LI ; Hua ZHOU ; Wanjun LI ; Jiacai LIN ; Shengyuan YU ; Jun WANG ; Xiangyu CAO ; Chenglin TIAN
Chinese Medical Journal 2024;137(5):588-595
Background::Cerebrovascular disease (CVD) ranks among the foremost factors responsible for mortality on a global scale. The mortality patterns of CVDs and temporal trends in China need to be well-illustrated and updated.Methods::We collected mortality data on patients with CVD from Chinese Center for Disease Control and Prevention’s Disease Surveillance Points (CDC-DSP) system. The mortality of CVD in 2020 was described by age, sex, residence, and region. The temporal trend from 2013 to 2019 was evaluated using joinpoint regression, and estimated rates of decline were extrapolated until 2030 using time series models.Results::In 2019, the age-standardized mortality in China (ASMRC) per 100,000 individuals was 113.2. The ASMRC for males (137.7/10 5) and rural areas (123.0/10 5) were both higher when stratified by gender and urban/rural residence. The central region had the highest mortality (126.5/10 5), the western region had a slightly lower mortality (123.5/10 5), and the eastern region had the lowest mortality (97.3/10 5). The age-specific mortality showed an accelerated upward trend from aged 55-59 years, with maximum mortality observed in individuals over 85 years of age. The age-standardized mortality of CVD decreased by 2.43% (95% confidence interval, 1.02-3.81%) annually from 2013 to 2019. Notably, the age-specific mortality of CVD increased from 2013 to 2019 for the age group of over 85 years. In 2020, both the absolute number of CVD cases and the crude mortality of CVD have increased compared to their values in 2019. The estimated total deaths due to CVD were estimated to reach 2.3 million in 2025 and 2.4 million in 2030. Conclusion::The heightened focus on the burden of CVD among males, rural areas, the central and western of China, and individuals aged 75 years and above has emerged as a pivotal determinant in further decreasing mortalities, consequently presenting novel challenges to strategies for disease prevention and control.
10.Perioperative efficacy analysis of robotic surgical system assisted anatomic and non-anatomic hepatectomy
Tian HANG ; Zheyong LI ; Mingyu CHEN ; Jiang CHEN ; Junhao ZHENG ; Liye TAO ; Linghan GONG ; Zaibo YANG ; Chao SONG ; Xiao LIANG
Chinese Journal of Digestive Surgery 2023;22(4):497-504
Objective:To investigate the perioperative efficacy of robot surgical system assisted anatomic and non-anatomic hepatectomy.Methods:The propensity score matching and retrospective cohort study was conducted. The clinical data of 103 patients who underwent robot surgical system assisted hepatectomy in Sir Run Run Shaw Hospital, Affiliated with the Zhejiang University School of Medicine from March 2016 to December 2021 were collected. There were 54 males and 49 females, aged 56(range, 44?64)years. Of the 103 patients, 55 cases undergoing robot surgical system assisted anatomic hepatectomy were divided into the anatomic group, and 48 cases undergoing robot surgical system assisted non-anatomic hepatectomy were divided into the non-anatomic group. Observation indicators: (1) propensity score matching and comparison of general data of patients between the two groups after matching; (2) intraoperative conditions; (3) perioperative complications. Propensity score matching was done by the 1:1 nearest neighbor matching method. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the t test. Measurement data with skewed distribution were expressed as M(range), and comparison between groups was conducted using the Mann-Whitney U test. Count data were described as absolute numbers or percentages, and comparison between groups was conducted using the chi-square test or Fisher exact probability. Comparison of ordinal data was conducted using the rank sum test. Results:(1) Propensity score matching and compari-son of general data of patients between the two groups after matching. Of the 103 patients, 94 cases were successfully matched, including 47 cases in the anatomic group and 47 cases in the non-anatomic group. The elimination of preoperative body mass index, preoperative platelet and preoperative albumin confounding bias ensured comparability between the two groups after propensity score matching. (2) Intraoperative conditions. After propensity score matching, the operation time and volume of intraoperative blood loss were 175(range, 120?240)minutes and 50(range, 50?100)mL in patients of the anatomic group, versus 155(range, 105?190)minutes and 100(range, 50?200)mL in patients of the non-anatomic group, showing significant differences in the above indicators between the two groups ( Z=1.97, 2.49, P<0.05). (3) Perioperative complications. After propensity score matching, cases with pleural fluid and/or ascites, case with biliary fistula, case with thrombosis, case with peritoneal infection, case with incision infection were 11, 1, 2, 4, 1 in patients of the anatomic group, versus 12, 0, 4, 1, 0 in patients of the non-anatomic group, showing no significant difference in the above indicators between the two groups ( P>0.05). Cases with complications classified as grade Ⅰ, grade Ⅱ, grade Ⅲ, grade Ⅳ of the Clavien-Dindo classification were 33, 14, 0, 0 in patients of the anatomic group, versus 28, 14, 3, 2 in patients of the non-anatomic group, showing no significant difference in the above indicators between the two groups ( Z=?1.38, P>0.05). Conclusions:Robotic surgical system assisted anatomic and non-anatomic hepatectomy are safe and feasible for clinical application. Compared with robot surgical system assisted non-anatomic hepatectomy, patients under-going robot surgical system assisted anatomic hepatectomy have long operation time and less volume of intraoperative blood loss.

Result Analysis
Print
Save
E-mail