1.Effect of determination of metals in Cardeniajasminoides Ellis by ICP-MS from online internal standard solution
Yali ZHANG ; Wei SUN ; Lei ZHANG ; Mingpeng MAO ; Zhengliang YE
Drug Evaluation Research 2017;40(4):500-505
Objective To provide a proper concentration of Internal Standard Solution by comparing five different degrees to the simultaneous analysis of 10 metals including V,Cr,Mn,Fe,Ni,Cu,As,Cd,Pb and Hg in Cardeniajasminoides.Method An Inductively Coupled Plasma-Mass Spectrometry method with Microwave-Assisted Digestion was developed with10,50,200,500,1 000 μg/L of Ge,In,Bi as internal standard.Result The degree of 500 μg/L concentration of internal stand solution can both correct the matrix effect and alleviate the contamination as the 1 000 μg/L.Conclusion With excellent detection limits,high sensitivity and wide linear range,the 500 μg/L internal standard may serve as reference in the determination of elements in other traditional Chinese medicine (TCM).
2.Study on Contents Determination and Transport Rates of 18 Toxic Elements from 10 Ingredients of Modi-fied Xiaoyao Formula and Their Extracts
Yali ZHANG ; Wei SUN ; Lei ZHANG ; Mingpeng MAO ; Zhengliang YE
China Pharmacy 2017;28(18):2564-2568
OBJECTIVE:To establish a method for simultaneous determination of 18 toxic elements from 10 ingredients of Modified xiaoyao formula and their extracts,and to study transport rates of above elements. METHODS:Microwave digestion-in-ductively coupled plasma mass (ICP-MS) was used to determine above elements. Radio-frequency power was 1.50 kW,atomiza-tion pressure was 720 kPa,sampling depth was 7 mm,plasma gas flow rate was 15.0 L/min,carrier gas flow rate was 1.00 L/min, spray chamber temperature was 2℃,He flow rate was 4.5 mL/min under collision mode,measurement points/peak was 3,data ac-quisition mode was jump mode. RESULTS:The linear ranges of As,Pb,Cu,Hg,Cd,Mo,V,Cr,Mn,Fe,Ni,Zn,Ru,Rh, Pd,Os,Ir,Pt was 0-500.17 ppb(r was 0.9994-09999);LOD was 0.0004-5.3410 ng/g;RSD of repeatability tests was all lower than 5.0%;average recoveries were 82.0%-117.9%(RSD=0.2%-5.7%,n=9). Ru,Rh,Pd,Os,Ir,Pt,Hg had not been detect-ed. The transfer rates of 11 metals in the extracts ranged 1.46%-31.90%. CONCLUSIONS:The method is simple,precise,stable and repeatable,and can be used for simultaneous determination of 18 toxic elements in 10 ingredients of Modified xiaoyao formula and their extracts. The contents of toxic elements are decreased during the preparation of Modified xiaoyao formula extract to guar-antee the safety of drug use to certain extent.
3.Accuracy of evaluate coronary soft plaque by multi-slice CT
Dingbiao MAO ; Yanqing HUA ; Guozhen ZHANG ; Mingpeng WANG ; Weilan WU ; Fei HU ; Qiyong DING ; Xiaojun GE
Chinese Journal of Radiology 2001;0(07):-
Objective To evaluate accuracy of density measurements within coronary plaque by multi-slice spiral CT and factors that influence measurements. Methods Four adult cadaver hearts were used. Thrombus and pericardial fat which acquired from specimen (size 2.0, 1.5, 1.0 and 0.5 mm respectively) were placed into coronary artery to simulate coronary plaques. The contrast medium (three different concentrations 1: 30, 1:40, and 1:50) were injected into coronary artery. The raw date were reconstructed with two slice width ( 1. 00 and 0. 75 mm). Results When contrast medium concentrations was 1: 30, the CT values of thrombus were 109 HU ( slice width 1. 00 mm, size 2. 0 mm) , 115 HU ( slice width 1.00 mm, size 1.5 mm), 101 HU (slice width 0.75 mm, size 2.0 mm), 113 HU ( slice width 0. 75 mm,size 1. 5 mm) ; the CT values of fat were - 23 HU ( slice width 1. 00 mm, size 2. 0 mm) , -17 HU(slice width 1.00 mm, size 1.5 mm) , -9 HU(slice width 1.00 mm, size 1.0 nun), -27 HU ( slice width 0.75 mm, size 2. 0 mm) , - 19 HU (slice width 0.75 mm, size 1. 5 mm) , - 13 HU (slice width 0. 75 mm,size 1. 0 mm). When contrast medium concentrations was 1: 40, the CT values of thrombus were 79 HU( slice width 1.00 mm,size 2.0 mm) , 87 HU( slice width 1.00 mm, size 1. 5 mm) , 115 HU( slice width 1. 00 mm,size 1. 0 mm) , 73 HU(slice width 0. 75 mm,size 2. 0 mm) , 80 HU(slice width 0. 75 mm, size 1. 5 mm) , 110 HU( slice width 0. 75 mm, size 1. 0 mm) ; the CT values of fat were - 31 HU ( slice width 1. 00 mm, size 2. 0 mm) , - 22 HU ( slice width 1. 00 mm, size 1. 5 mm) , - 10 HU ( slice width 1.00 mm,size 1.0 mm) , -35 HU(slice width 0. 75 mm,size 2.0 mm) , -25 HU(slice width 0. 75 mm, size 1. 5 mm) , - 19 HU ( slice width 0. 75 mm, size 1. 0 mm). When contrast medium concentrations was 1:50, the CT values of thrombus were 53 HU ( slice width 1. 00 mm, size 2. 0 mm) , 60 HU ( slice width 1.00 mm,size 1.5 mm) ,63 HU(slice width 1.00 mm,size 1.0 mm) ,51 HU(slice width 0.75 mm,size 2. 0 mm) ,64 HU( slice width 0. 75 mm,size 1. 5 mm) ,67 HU( slice width 0. 75 mm,size 1. 0 mm) ,145 HU (slice width 0. 75 mm, size 0. 5 mm) ; the CT values of fat were - 39 HU ( slice width 1. 00 mm, size 2. 0 mm) , -28 HU( slice width 1. 00 mm,size 1. 5 mm) , - 22 HU( slice width 1. 00 mm,size 1. 0 mm) , 17 HU(slice width 1. 00 mm,size 0. 5 mm) , -41 HU(slice width 0. 75 mm,size 2. 0 mm), -36 HU(slice width 0. 75 mm, size 1. 5 mm ) , - 27 HU ( slice width 0. 75 mm, size 1. 0 mm ) , 3 HU ( slice width 0. 75 mm, size 0. 5 mm ) . The density values of thrombus were correlated with size ( t = - 6. 624, P 0. 05) not found statistically significant may be caused by both too close slice width (1.0 mm and 0. 75 mm) and few samples. The slice width(t= -2. 595,P
4.Clinical application of low-dose CT in patients with rib fractures
Xiaojun GE ; Hao WU ; Yanqing HUA ; Mingpeng WANG ; Dingbiao MAO ; Ping TANG ; Fei HU ; Guozhen ZHANG
Chinese Journal of Radiology 2011;45(5):492-495
Objective To evaluate images quality and diagnostic feasibility of low-dose CT in patients with traumatic rib fractures.Methods Twenty-five patients presented with thoracic iniury were underwent 64-slice spiral CT scanning in inspiration breath-hold technique.Two scan protocols were performed.In one scan protocol noise index(NI)is 11,and in another NI is 21,but the other scan parameters were no difference.The mean value of tube current,the volume CT dose index(CTDIvol),and effective dose(ED)were recorded.Image quality was scored by 2 experienced radiologists using the 5-points scale.The numbers and degrees of rib fractures were recorded.The data were tested by using the Wilcoxon signed rank sum test.The differences of the inter-observer were determined by Kappa statistics.Results The mean CTDIvol and ED in scan protocol with NI of 11 were(13.88±5.17)mGy and(8.14±3.21)mSv,and that with NI of 21 were(3.91±1.57)mGy and(2.31±0.97)mSv.Compared the scan with NI of 11.there was 72%intrinsie dose reduction in the scan with NI of 21.The mean value of tube current in scan with NI of 11 and 21 were(195.88±69.33)mAs and(54.56±21.54)mAs.AIl patients with 11 and Ⅲ degree and most patients with I degree rib fractures that identified by the scan with NT of 11 were detected by the scan with NI of 21.There were no statistical difference between two scaus with the Wilcoxon signed rank sum test.The diagnostic acceptability and image noise score in the scan with NI of 11 were 4.9±0.2 and 4.6±0.5.and that with NI=21 were 3.5±0.5 and 3.3±0.5.There was prefect concordante in the inter-observers in diagnostic acceptability on finding of rib fractures.diagnostic acceptability and image noise(Kappa=0.876,0.820,0.792,P<0.01)between two scan protocols.Conclusion Rib fractures can be diagnosed by the low-dose CT using the scan protocol with NI of 21.