With the extensive use of information technology and the development of big data technology, the traditional treatment methods for cancer are not meeting our needs.The application of medical large data has now changed our tumor treatment model profoundly, but also brings a deeply cognition to the nature of malignant tumor.Development of medical big data analysis and management technologies are driving malignancy treatment model fromindividual treatment era into the precision medicine era, which allows us to change the prediction, diagnosis, treatment and monitor of malignancy.There are also a variety of challenges to resolve.
2.The comparative analysis of automatic blood analyzer Sysmex XT-2000i and Mindray BC-5800
Congxiang WANG ; Jing ZHANG ; Mingfei XIANG ; Haining WANG
International Journal of Laboratory Medicine 2014;(17):2372-2373
Objective To compare the precision and correlation of test parameters betwee the two types of automatic blood ana-lyzer,Sysmex XT-2000i and Mindray BC-5800.Methods We selected 60 cases of EDTA-K2 anticoagulant whole blood samples, correlation analysis was carried out on the two instrument parameters,and high,medium and low value samples were chosen for 10 times′precision analysis in the two instrument s respectively.Results The variation coefficient(CV)values of blood count parame-ters of Sysmex XT-2000i were 0.02%-5.70%,while the CV values of white blood cell classification parameters were 0.06%-1. 66%.The CV values of blood count parameters of Mindray BC-5800 were 0.02%-5.3%,white the CV values of white blood cell classification parameters were 0.09%-1.17%.The determination coefficient(r2 )of each parameter of the two instruments were 0. 185-0.995.Conclusion the correlation between the two instruments is good,and the two instruments′precisions were consistent with the design range.
3.Application of fibular flap with partial continuous periosteum and cortex in hip preservation surgery for femoral head necrosis
Mingfei HE ; Yanwen LEI ; Zhongming HUANG ; Chuanghao YU ; Yi LUO ; Xiang WU ; Zengyang GAO ; Jingliang ZHANG
Chinese Journal of Microsurgery 2021;44(6):625-628
Objective:To investigate the short-term clinical effect of using fibular flap with preserving the continuity of fibula in hip preservation surgery for femoral head necrosis.Methods:From September, 2017 to November, 2020, 13 cases of femoral head necrosis were repaired with fibular flap. The fibular flaps were cut with an improved method for preserving the continuity of the fibular cortex, and the donor sites were sutured directly. The fibuls were inserted into the femoral heads with single or double segment folding support. Autogenous iliac crest combined with platelet-rich plasma(PRP) was used for impaction of bone grafting in femoral head, and the fibular flaps were anastomosed with 1 artery and 2 veins. All follow-up data were obtained, including bone union by X-ray and CT as well as the functional recovery of the hip joint and donor site. Statistical analysis was performed. P<0.05 was considered statistically significant. Results:The followed-up time ranged from 6 to 23 months. The fibular bones were significantly thicker and the incisions healed well at the donor sites. There was neither abnormal sensation in toes, dorsal foot, and lateral of the leg, nor significant influence on foot function. The hip joint activities were normal. The outcome was proved to be remarkable according to the Harris score(from 58.9±10.6 points before surgery to 81.7±10.6 points after surgery), the difference was statistically significant ( P<0.05) . Conclusion:The method of the improved fibular flap in hip preservation surgery is beneficial to the repair and reconstruction of the necrotic femoral head since the donor area is less traumatic, and a satisfactory clinical effect can be obtained.