1.Design and implementation of maintenance management system for medical equipment based on HIS
Gang LIU ; Xianghu WU ; Mingcheng QU
Chinese Medical Equipment Journal 2003;0(12):-
A maintenance management system for medical equipment is developed based on HIS.The system contains some special functions(including preventive maintenance,automatic job distribution,performance assessment,etc.)which are very useful for confirming the medical equipment in proper conditions and promoting the working efficiency of the staff.The system provides a technical support for the improvement of the maintenance management level.The CS/BS combined mode is adopted so that the maintenance is exempted at the users' end,and the data operation and statistical work become convenient at the engineering department's end.Furthermore,it provides a platform for future hospital information integration.
2.Development and Evaluation of DNA Authenticity Identification Kit for Genuine Medicinal Materials Gastrodia Elata
Qiuhe MA ; Yuhe MA ; Yue LIU ; Tao LI ; Lijun GAO ; Wei XIA ; Mingcheng LI ; Yongmei QU
Chinese Journal of Modern Applied Pharmacy 2024;41(9):1198-1203
OBJECTIVE
To develop a DNA authenticity identification kit of Gastrodia elata that combined DNA extraction technology with PCR technology, and to evaluate the performance of the kit methodologically.
METHODS
The ITS2 sequences of Gastrodia elata and its common forgeries, such as amabilis root, dahlia tuber and potato, were found by the National Center for Biotechnology Information(NCBI). DNAMAN was used for multi-sequence alignment, and NCBI-primer-blast was used to design specific primers of Gastrodia elata. Improved DNA extraction method to ensure efficient extraction of authentic Gastrodia elata and its common forgeries genomic DNA, UV spectrophotometry was used to measure the concentration and purity. The PCR reaction system was optimized, the composition and reaction conditions of the kit were determined, and the commercially available gastrodia elata samples were randomly sampled.
RESULTS
The DNA purity OD260/OD280 values of the samples extracted by the developed kit were (1.87±0.13). The minimum detection limit was 10 ng·μL−1, and the result of repeated detection was the same for 3 times. Repeated freezing and thawing for 5, 10, 15, 20 times had no effect on the detection effect, and it could be stored at −20℃ for 1 year, among 10 commercially available gastrodia elata samples tested, 7 were authentic and 3 were counterfeit.
CONCLUSION
The DNA authenticity test kit is highly specific, sensitive, reproducible and stable, and the test results are accurate, it is suitable for the rapid identification of asparagus and its common forgeries.