2.Association of Interleukin-1?-511C/T and Interleukin-1?+3953C/T Polymorphisms with Susceptibility of Pediatric Epilepsy
hai-ying, LU ; song-ming, HUANG ; ai-hua, ZHANG ; guo, ZHENG ; yan-jun, HUANG
Journal of Applied Clinical Pediatrics 2006;0(14):-
Objective To explore the relationship between IL-1?-511C/T and IL-1?+3953C/T site polymorphisms and the susceptibility of pediatric epilepsy.Methods Under the case-control study,IL-1?-511C/T and IL-1?+3953C/T site polymorphisms in 117 patients with pediatric epilepsy and 95 healthy individuals controls(healthy control group) were analyzed with polymerase chain reaction restriction and fragment length polymorphism(PCR-RFLP),the relationship between IL-1?-511C/T,IL-1?+3953 C/T site polymorphisms and the risk of pediatric epilepsy were analyzed.SAS 8.0 software was used to analyze the data.Results Multiple variate logistic regression analysis revealed that compared with healthy control group,there was no relationship between the IL-1?-511C/T site polymorphisms and the susceptibility of pediatric epilepsy individuals,carrying at least one +3953T variant allele(CT and TT genotypes) had a significantly increased risk for pediatric epilepsy(adjusted OR=2.46,95%CI 1.03-5.87),compared with the wild-type genotype(+3953CC).Furthermore,individuals with epilepsy or febrile seizures family history had a significantly higher risk(adjusted OR=4.12,95%CI 1.28-29.34),compared with those with both CC genotypes.Conclusions These findings support the hypothesis that IL-1?-511C/T site polymorphisms have no relationship with epilepsy,but the IL-1?+3953C/T polymorphism may contribute to the risk of developing pediatric epilepsy.
3.Effect of Paridis Rhizoma total saponins on apoptosis of human gastric cancer cell MKN-45 and Fas/FasL signaling pathway.
Hai-yan FANG ; Xiao-yan GONG ; Xing-hui HONG ; Ming-liu HUA ; Jin-ling HUANG
China Journal of Chinese Materia Medica 2015;40(7):1388-1391
OBJECTIVEThe study aimed to test if Paridis Rhizoma total saponins (PRTS) could induce apoptosis of human gastric cancer cell MKN-45.
METHODBased on the previous researches, PRTS was set by different concentrations to treat human gastric cancer cell for 12 h (5, 10, 20 mg x L(-1)). Fluorescent staining methods were adopted to observe apoptotic morphological changes of MKN-45. The apoptosis rates were analyzed by flow cytometry with Annexin V-FITC/PI staining. The enzymatic activities of caspase-3 and caspase-8 were measured by ELISA. The protein levels of Fas and FasL were detected by Western blotting.
RESULTUnder a fluorescence microscope, MKN-45 treated by PRTS was seen typical apoptotic morphological features. PRTS significantly increased the rate of apoptosis. Compared with the control group, there exsited significant differences in apoptosis rate of PRTS concentration of 20 mg x L(-1) (P < 0.01); besides, the enzymatic activities of caspase-3 and caspase-8 were promoted obviously after the effect of PRTS on MKN-45 cells for 12 h (P < 0.01). The protein levels of Fas and FasL in the MKN-45 were upgraded significantly.
CONCLUSIONPRTS can induce apoptosis of human gastric cancer cell MKN-45 , which is concerned with caspase-3 and caspase-8 and upgraded Fas and FasL.
Apoptosis ; drug effects ; Caspase 3 ; genetics ; metabolism ; Caspase 8 ; genetics ; metabolism ; Cell Line, Tumor ; Drugs, Chinese Herbal ; pharmacology ; Fas Ligand Protein ; metabolism ; Humans ; Magnoliopsida ; chemistry ; Rhizome ; chemistry ; Saponins ; pharmacology ; Signal Transduction ; drug effects ; Stomach Neoplasms ; drug therapy ; genetics ; metabolism ; physiopathology ; fas Receptor ; metabolism
4.Management of congenital cataract with different technique: phacoemulsification I/A and 23-gauge system
Yan-Ming, HUANG ; Jin-Hong, CAI ; Hai-Bo, LI ; Yan, CHEN
International Eye Science 2010;10(7):1237-1240
AIM: To evaluate the efficacy and safety of two different surgical techniques on congenital cataract on children.METHODS: Twenty-two children (1-3 years old) with congenital cataract were randomly divided into two groups (group A and group B). With group A (10 patients, 20 eyes), we applied 23-gauge (23G) trans corneal limbus vitrectomy system to complete lens cortex gettering, posterior capsulotomy and anterior vitrectomy;With group B (12 patients, 24 eyes), we used the phacoemulsification I/A to complete lens cortex gettering, and performed anterior vitrectomy with anterior vitreous cutting instrument. After that, the differences in intraoperative and postoperative complications between two groups were compared. RESULTS:In group A, the width of corneal limbal incision was 0.6mm, the incision was self-sealing, and the anterior chamber was stable and iris did not prolapse during the surgery. In group B, the width of corneal limbal incision was 3mm, anterior chamber was unstable and intraoperative iris prolapse occurred in 14 eyes (58%). And the incision need to be stitched up after surgery. In the postoperative follow-up of 6-24 months (an average of 14 months), we found that corneal neovascularization did not occur in group A, while in group B, corneal neovascularization occurred in four eyes (17%); Other complications, such as posterior capsular opacification,retinal detachment, glaucoma, hypotony or endophthalmitis did not occur in either group.CONCLUSION: The 23G trans corneal limbus vitrectomy system used in pediatric cataract surgery is safer and more effective than phacoemulsification I/A. It is promising in treatment of congenital cataract on children.
5.Evaluation of long term effects of arthroscopic knee debridement and reconstructing for treating osteoarthritis in patients with Kaschin-Beck disease
Ming, LING ; Xiang-hui, HUANG ; Zhi, YI ; Yan-hai, CHANG ; Jun, LIU ; Jie, QI ; Xin, TIAN
Chinese Journal of Endemiology 2010;29(5):559-561
Objective To observe the long term effects of arthroscopic knee debridement and reconstructing operation for treating osteoarthritis in patients with Kaschin-Beck disease. Methods Thirty-one cases of patients with Kaschin-Beck disease were followed for 6 years after operation of articular clearing by arthroscope. Index of pain, symptoms of self-evaluation, range of motion, walking distance, standing test by affected leg when bending at 30° or 60° were recorded and compared with the preoperative results. Results Twenty-four cases were followed up for 6 years. Six years after operation the pain index(3.38 ± 2.87) was dramatically decreased compared to that before operation (6.88 ± 1.45, t = 5.30, P < 0.05). Patients symptoms markedly improved by subjective self-evaluation was 70.83% (17/24), the effective rate was 100% (24/24). The number of cases that could stand up when leg bending at 30° or 60° were 21,18 cases, respectively, compared with that of preoperative of 14, 11 cases, respectively, the difference was statistically significant(x2 = 5.17,4.27, all P < 0.05). Six years after operation the walking distance(3 cases < 1 km, 11 cases 1 - 5 km and 10 cases > 5 km) were greatly improved compared to the results before operation (12 cases < 1 km, 9 cases 1 - 5 km and 3 cases > 5 km, U = 2.88, P <0.05). Six years after operation the knee activity[(132.25 ± 14.52)°] remained at the same level, compared with that of preoperative [(131 .58 ± 14.68) °], the difference was not statistically significant (t = 0.16, P > 0.05) .Conclusions The method of arthroscopic joint debridement to cure Kaschin-Beck disease knee osteoarthritis can significantly reduce pain, improve function and walking distance, with more stable long-term satisfactory outcome.
6.The relationship with fat liver in children with simple obesity
Dong-Ping LIU ; Xian-Ming GONG ; Chun-Hua LI ; Hai-Zhong HUANG ;
Chinese Journal of Primary Medicine and Pharmacy 2006;0(07):-
Objective To search the relationship among blood pressure,blood lipid and fat liver in childrcn with simple obesity.Methods Blood pressure,blood lipid and ultrasound of liver of 40 cases with simple obesity and 20 cases in normal control had been detected.Results there were 11 cases without complication in children with simple obesity,the simple obesity with hypertension complication were 14 cases,and the simple obesity with high blood lipid were 15 cases.The level of total cholestrrol(TC),triglyceride(TG),light density lipoprotein(LDL)and very light density lipoprotein(VLDL)in obesity children were significantly higher than those of control group(P
7.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
8.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
9.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
10.Meta analysis of comparison of central corneal thickness measurement between Pentacam and A-scan in normal people
Shi-ming, CHENG ; Yan, LI ; Jin-hai, HUANG ; Xia, ZHOU ; Ling, XU
Chinese Journal of Experimental Ophthalmology 2013;(2):172-176
Background Central corneal thickness (CCT) is one of important parameters of the anterior eye segment.It plays a very important part in corneal refractive surgery and diagnosis of glaucoma.Contacted A-scan remains the gold standard for CCT measurement.Ophthalmologists are trying to look for a more convenient and noncontacted instrument to take place of contacted A-scan for CCT measurement.Objective This system analysis was to evaluate the difference between Pentacam and A-scan in CCT measurement.Methods A systematic literature retrieval was conducted from the MEDLINE,EMbase,Google Scholar,CBM disc and CNKI database with the limitation of publishing time from January 2005 to May 2011.The literature text was limited to the comparison of the CCT values measured by Pentacam and A-scan.The statistical analysis was performed using RevMan 5.1.0 software.Sensitive analysis was carried out and the publishing bias was analyzed using inverted funnel plot.Results A total of 26 studies met the requirement were included in this Meta-analysis with the 12 pieces of Chinese article and 14 pieces of English article,with the total eyes 3677.Heterogeneity was found anmong included studies (P =0.0003,I2 =56%) and random effects model was used.The differential value of CCT derived by Pentacam and A-scan was 1.74 μm,and no significant difference was found between Pentacam and A-scan (WMD =1.74,95% CI:-0.69-4.16,P>0.05).Fixed effects model was used to exclude the studies with the sample more than 100 eyes as the sensitive analysis.When fixed effect model was used,CCT by Pentacam was 2.73 μm more than A-scan,showing an insignificantly clinical difference.When studies with a sample more than 100 eyes were excluded,the CCT value by Pentacam was 2.64 μm more than A-scan,without clinically significant difference between them.No obvious publishing bias was seen in the included literature.Conclusions The difference between Pentacam and A-scan in CCT measurement is less and could be ignored.