2.Clinical and Electroencephalography Characteristics of Benign Epilepsy with Centro-Temporal Spikes in Children
qiu-ju, WANG ; sheng-ming, HUANG ; xi-shun, HUANG
Journal of Applied Clinical Pediatrics 2004;0(07):-
Objective To summarize the clinical and electroencephalography(EEG) characteristics of benign epilepsy with centro-temporal spikes (BECTS) in children.Methods The clinical manifestations,EEG findings,response to drug treatment and prognosis of 35 children with BECTS from Jul.2003 to Dec.2008 in the First Affiliated Hospital of Zhengzhou University were analyzed retrospectively.Results In the 35 cases,the age of onset was 2.5 to 14.0 years old,and the peak age of onset was 6-10 years old(62.9%).Twenty-two cases mainly presented partial seizures:hemifacial convulsions,sialorrhea,sounds,limb tonic-clonic seizures,and secondary generalized seizures.Thirteen cases were only describled generalized tonic-clonic seizures.Seizures were closely related to sleep and almost occurred shortly after falling asleep or before waking up.There were 26 cases who displayed convulsion during sleeping,including noon break.The EEG features showed numerous or single spikes on one side or both sides in the central and temporal areas under the background of normal activity in interictal period.The release frequency of abnormal wave was significantly increased after falling asleep,so the EEG monitoring during sleep could improve the positive rate of BECTS.Monotherapy with low-dose anti-epileptic drug could obtain good efficacy.Twenty-five cases stopped seizures within 3 months after therapy.Thirty-three cases hadn't get seizure since drug therapy at the age of 16 years old.So far,12 cases had been stopped medicine.Conclusions BECTS mostly begins at school-aged children,which displays partial seizures or secondary generalized seizures.The seizures are closely related to sleep.EEG monitoring during sleep which shows numerous or single spikes on the centrotemporal area has crucial diagnostic value to BECTS.There is a positive response to monotherapy with low-dose anti-epileptic drug and generally the prognosis is good.
3.Biocompatibility of Filtek~(TM) Z350 resin with dental pulp tissues of beagle dogs
Xiaojing HUANG ; Lishan LEI ; Sheng ZHONG ; Ming ZHANG
Chinese Journal of Tissue Engineering Research 2007;0(41):-
BACKGROUND:Nano-size inorganic filling greatly improves mechanic characteristic of composite resin.However,its effects on pulp tissue remain unclear.OBJECTIVE:To evaluate the biocompatibility of FiltekTM Z350 nano-composite resin on dog pulp tissue by means of histology observation.DESIGN,TIME AND SETTING:Randomized control animal experiment was performed at the animal experiment center of Fuzhou General Hospital,Nanjing Military Area Command of Chinese PLA from April 2007 to April 2008.MATERIALS:Sixty healthy teeth from three adult male beagle dogs were recruited in this study.METHODS:Buccal Class V deep cavities were prepared in beagle dogs,which were then divided into four groups at random.FiltekTM Z350 resin,Dyract AP compomer and TPH resin were used to restore the cavities in three testing groups and glass ionomer cement was used as control.All cavities were treated with Clearfil SE BOND before filling.Intact healthy teeth were used as blank control.MAIN OUTCOME MEASURES:The pulp condition of each tooth was studied histologically.The remaining dentine thickness of each cavity was measured.RESULTS:After 7 days,mild inflammatory response was observed in most of the specimens.After 30 and 90 days,normal histological characteristics were observed in almost all specimens except TPH resin group.The histological structure disturbance of dentin cell layer emerged in some specimens of TPH group,which was higher than other testing groups(P 0.05).CONCLUSION:FiltekTM Z350 nano-composite resin has similar biocompatibility as Dyract AP compomer and glass ionomer cement,better than TPH resin.
4.Quantitative models of Raman spectroscopy for five kinds of traditional Chinese medicine containing CaCO3 based on an improved siPLS.
Long CHEN ; Ming-yang YUAN ; Jing MING ; Yi-mei LIU ; Bi-sheng HUANG ; Ke-li CHEN
China Journal of Chinese Materia Medica 2015;40(18):3608-3615
The aim of this paper is to apply Raman spectroscopy technique to develop rapid quantitative models for five kinds of Traditional Chinese Medicine containing CaCO3. In the experiment, Raman spectras of 67 batch of sample including Otolithum Sciaenae, Galaxeae Os, Ophicalcitum, Calcite, Stalactite and their mixture which had different content of CaCO3 were collected, and the quantitative models were established by using an improved siPLS to optimize the characteristic spectral bands and using the CaCO3 contents which were measured by EDTA titration method as references. Compared with the results by EDTA titration, the established quantitative model for CaCO, content showed a prediction result that the average relative deviation of the prediction results is 2. 71% and the average recovery rate was 100.46%, when the content is between 0.465 4-0.999 7, and when the characteristic spectral bands of 1 290-1 280, 730-714, 700-690, 660-650, 465-460, 455-445, 405-385 cm(-1) had been optimized. The result also showed that the model using Raman spectroscopy and based on an improved siPLS can get a rapid determination for contents of 5 kinds of Traditional Chinese Medicine containing CaCO3.
Calcium Carbonate
;
chemistry
;
Drugs, Chinese Herbal
;
chemistry
;
Least-Squares Analysis
;
Models, Statistical
;
Plants, Medicinal
;
chemistry
;
Spectrum Analysis, Raman
;
methods
5.Analysis of influencing factors of multi-site work-related musculoskeletal disorders in surgeons
HUANG Kai sheng HUANG Dang sheng WU Yun PENG Zhi heng SHI Yi ming WANG Zhong xu YANG Min
China Occupational Medicine 2022;49(05):493-
Objective - -
To analyze the prevalence and influencing factors of multi site work related musculoskeletal disorders
( ) Methods
WMSDs in surgeons. A total of 102 surgeons from four hospitals were selected as study subjects by convenient
sampling method. The Chinese version of Musculoskeletal Disorders Questionnaire was used to investigate the prevalence of
, Results
WMSDs in the past one year the related individuals and occupational factors. The total prevalence of WMSDs among
( ), ( ) ( )
surgeons was 54.9%. The top three sites were neck 48.0% lower back 35.3% and shoulder 32.4% . The prevalence of
( vs ,P )
WMSDs in multiple sites was higher than that in a single site 43.1% 11.8% <0.01 . Multivariate logistic regression
, ,
analysis showed that surgeons who smoked were tired at work and had a bent back had a higher risk of developing WMSDs
[ ( - ), ( - ), ( - ), P ]
odds ratios and 95% confidence intervals were 3.66 1.41 9.46 8.33 2.15 32.20 and 18.74 2.14 166.77 all <0.01
Conclusion -
after excluding the influence of confounding factors. The prevalence rate of multi site WMSDs among surgeons is
,
high and the influencing factors include bad living habits and occupational factors such as working load and working posture.
6.The effect of selectively upward placement of acetabular implants on limb length and post-operative function of develop-mental dysplasia of the hip patients with shortened legs
Zhiyu HUANG ; Zhiqi ZHANG ; Ming FU ; Guangxin HUANG ; Peihui WU ; Baoxi YU ; Puyi SHENG ; Weiming LIAO
Chinese Journal of Orthopaedics 2014;(12):1225-1230
Objective To investigate the effect of selectively upward placement of acetabular implants on limb length and post?operative function of developmental dysplasia of the hip patients with shortened legs during total hip arthroplasty (THA). Methods Twenty?six cases of developmental dysplasia of the hip received THA between January 2008 and December 2013, in?cluding 12 cases of Crowe typeⅠ, 8 of Crowe typeⅡ, 6 of Crowe typeⅢ. There were 5 males and 21 females with an average age of 62.7 years (range, 36-80 years). The left hip was involved in 9 cases and the right hip in 17 cases. The preoperative mean Har?ris score was 42.30±12.84, and the preoperative mean WOMAC score was 59.08±13.84 at the last follow?up. The anteroposterior X?ray films and CT scan of the pelvis, anteroposterior and lateral X?ray films of the femur, and TraumaCad analysis were conducted routinely preoperation. More than 70%of the bone?implant interface was covered by appropriate upward distance of acetabular im?plant. Results The follow?up time ranged from 6 to 73 months (mean, 36 months). The Harris score improved to 91.18±7.09, and WOMAC score reduced to 9.85±3.75. According to postoperative measurement, affected limb had been lengthened by 0-5 mm in 8 cases, 6-10 mm in 5 cases, 11-15 mm in 5 cases,>15 mm in 7 cases, and shortening increased 1 mm in 1 case, but the average lengthening was 9.23±7.54 mm. The upward distance of acetabular implant was 0-5 mm in 10 cases, 6-10 mm in 7 cases and>10 mm in 9 cases. The average lengthening was 6.60±6.72 mm in patients having 0-5 mm upward distance, 11.90±5.64 mm in patients having 6-10 mm upward distance and 10.11 ± 9.35 mm in patients having>15 mm upward distance, showing no significant differ?ence. The leg length discrepancy was-3.70±6.43 mm in patients having 0-5 mm upward distance, 1.71±6.24 mm in patients having 6-10 mm upward distance and 0.56 ± 7.70 mm in patients having>15 mm upward distance, showing no significant difference. Con?clusion The limb length could be improved by selectively upward placement of acetabular implants in developmental dysplasia of the hip patients with anatomically abnormal acetabulum during THA, with reasonable preoperative design and corrective operation.
7.Tomographic characteristics of optic nerve head on Heidelberg retina tomograph Ⅲ in healthy Chinese subjects
Bin, LIU ; Ming-guang, HE ; Sheng-song, HUANG ; Qiu-xia, YIN ; Xiao-hu, DING
Chinese Journal of Experimental Ophthalmology 2013;(7):664-667
Background Normal adult optic disc rim width follows inferior ≥ superior ≥ nasal ≥ temporal (ISNT) rule.Analysis of the optic disc structural parameters with Heidelberg retina tomograph (HRT) can understand whether ISNT principle is suitable to other optic disc structure parameters.Objective This study was to investigate the characteristics of optic nerve head structure parameters in normal Chinese adults.Methods The parents of twins who participated Guangzhou Twin Eye Study were enrolled in Zhongshan Ophthalmic Center from 2006 June to 2011 August.All subjects received the routine eye examinations,including visual acuity,slit lamp microscope,direct ophthalmoscope examination,auto-refraction examination and HRT Ⅲ examination.All data from the right eyes were collected and analyzed.HRT values from different quadrants of optical nerve head were compared with one-way analysis of variance,and the multiple comparison between quadrants was carried out by Bonferroni test.The differences of optical nerve head parameters in different gender were analyzed using independent sample t test and Bland-Altman test.Results In this study,1672 eyes of 1672 subjects were included,with the 759 male and 913 female persons and average age of (41.8±5.3)years.No significant differences were seen in the disc area (DA)between the superior and inferior,as well as the nasal and temporal quadrants among the subjects (P>0.05).In addition,there were not significantly different in the rim area (RA) between the superior and nasal disc as well as the rim volume (RV) among the inferior,superior and nasal disc (P>O.05).However,significant differences were found in the cup area (CA),cup/disk area ratio (C/DAR),cup volume (CV),mean cupdepth (MCD),maximum cup depth (MxCD),height variation contour (HVC),cup shape measure (CSM),mean retinal nerve fiber layer thickness (mRNFLT) and retinal nerve fiber layer cross section area (RNFLcsa) among the different quadrants (P<0.001).The local differences from only DA and RA complied with an ordination of the ISNT rule.The values of DA,CA,C/DAR,CV,MCD,MxCD from male individuals were higher,but those of the RV,HVC,mRNFLT RNFLcsa were lower in comparison with female individuals.Nevertheless,all the differences were < 0.1 with a maximal mean difference in DA and CA (both 0.07 mm2).Conclusions The optical nerve head configurations measured by HRT have different distributing characteristics in four quadrants in normal adults.Most parameters show the higher values in the inferior and superior than those in nasal and temporal of disc,but DA and RA meet ISNT rule.The differences of most parameters between male and female subjects can be ignored.
8.The impact of refractive errors and axial length on the structural parameters of the optic disc
Bin, LIU ; Ming-guang, HE ; Sheng-song, HUANG ; Qiu-xia, YIN ; Xiao-hu, DING
Chinese Journal of Experimental Ophthalmology 2013;31(10):953-957
Background Heidelberg Retinal Tomograph (HRT) has been widely used in clinical diagnosis of glaucomatous optic neuropathy,importantly,the measurement results of HRT may be affected by myopia.Therefore,studying the effect of different refractive status and axial length on structural parameters of the optic disc is important.Objective This study was to evaluate the influence of refractive error and axial length to optic nerve head parameter measured by HRT.Methods The parents who participate in Guangzhou Twin Study were enrolled in this investigation from July 2006 to August 2011.The regular eye examinations,including visual acuity,slit lamp,fundus,auto-refraction,HRT-Ⅲ and intraocular lens (IOL) Master,were performed on all the subjects.Thc data from right eyes of subjects were collected and analyzed.The linear correlation analysis and multiple linear regression analysis were applied to analyze the correlation between HRT optic papilla configuration parameter and equivalent sphere and ocular axis length.Results A pilot prospective series cases observational study was designed.1748subjects were enrolled in this study.The disc area (DA) (P=0.021),rim area (RA) (P<0.001),rim volume (RV) (P<0.001),mean retinal nerve fiber layer thickness (mRNFLt) (P<0.001) and retinal nerve fiber layer cross section area (RNFLcsa) in the high myopia were greater than those of the emmetropic group,with significant difference between the two groups (P<0.001).However,the cup area (CA),cup/disk area ratio (C/DAR) and cup volume (CV) were less in the high myopic group than those of the emmetropic group (P=0.004,P<0.001 and P<O.001),respectively.In the mild-moderatc myopic group,the RV,mRNFLt and RNFLcsa were greater than those of the emmetropic group (all of the P value less than 0.001),but the numbers of DA,CA,C/DAR,and CV were less than those of the emmetropic group,the differences were significant and their P valuables were 0.038,< 0.001,<0.001 and 0.001 respectively.The differences of structure parameters between the hyperopia group and the emmetropic group were not statistically significant (P>0.05).The DA,CA,RA,C/DAR,CV,RV,mean cup depth (MCD),maximum cup depth (MxCD),cup shape measure (CSM),mRNFLt and RNTLcsa were (2.04±0.43) mm2,(0.49±0.34) mm2,(1.55 ± 0.34) mm2,0.23-0.13,(0.11 ± 0.12) mm3,(0.45 ± 0.19) mm3,(0.21 ± 0.09) mm,(0.60±0.21) mm,-0.21 ± 0.07,(0.29 ± 0.07) mm and (1.46 ± 0.36)mm2,respectively,in the 1748 eyes of 1748 subjects.No significant correlation was found between the DA value with SE (r=-0.032,P =0.186).However,weaker positive correlations were seen between the CA,C/DAR,CV,MCD,MxCD with SE (r=0.139,0.163,0.130,0.004,0.054,P< 0.05) and negative correlation between RA,RV,mRNFLt and RNFLcsa with SE (r =-0.178,-0.331,0.241,-0.239,P<0.001).With the increase of the ocular axial length,the DA,RA,RV,mRNFLt and RNFLcsa values were enlarged,and the CV value was smaller.With the increase of CA,the RA,C/DAR,CV,RV,MCD,MxCD,CSM and RNFLcsa values elevated,but mRNFLt value was decreased.Conclusions Refractive error is not associated with DA,but the measuring results are different among various refractive groups.Refractive error,ocular axial length and DA affect the measuring result of HRT.
9.Light-dark box as a model of state anxiety in Kunming mice:three behavioral dimensions by factor analysis
Shiguang SUN ; Zifa LI ; Sheng WEI ; Ming HUANG ; Jian LIU ; Mingqi QIAO ; Huiyun ZHANG
Chinese Journal of Behavioral Medicine and Brain Science 2011;20(7):627-629
Objective To explore the behavioral dimensions and validity of the light-dark box(LDB),as an model of state anxiety in Kunming mice.Methods The behavior of adult,male,Kunming mice in LDB was recorded twice,for five minutes,with a one-week inter-trial interval.The following parameters were evaluated by factor analysis:latence for the first entry into the dark area(Latence);percentage of time exploring in the light area (Ltime%);percentage of squares crossing in the light area(Lcross%);percentage of rears in the light area (Lrear%);transitions between two areas(Transition);total number of squares crossing in the whole apparatus (Cross);total number of rears in the whole apparatus(Rear);and number of fecal boli(FB).Results There was a good intercorrelation both among Ltime%,Lcross%,Lrear%,and among Transition,Cross,Rear.A good correlation also was found between test and retest for Transition,Rear and FB.Ltime%,Lcress%and Lrear%had significant loadings on Anxiety factor(Loading%:39.54%,35.40%);Transition loaded on Locomotor factor(Loading%:23.78%,19.66%),combined with Cross;Rear loaded on Exploration factor(Loading%:13.75%,22.60%);and FB loaded on Emotionality factor(Loading%:14.42%,13.02%);Latence was not stable.Conclusion Light-dark box,as an animal model of state anxiety in Kunming mice,comprised three behavioral dimensions:anxiety factor,LDB-activity factor(locomotor factor and exploration factor)and emotionality factor.
10.The open field test as a method for ethology in Kunming mice: test-retest reliability
Shiguang SUN ; Jingjing WANG ; Zifa LI ; Ming HUANG ; Jian LIU ; Sheng WEI ; Huiyun ZHANG ; Mingqi QIAO
Chinese Journal of Behavioral Medicine and Brain Science 2010;19(12):1093-1095
Objective To explore the test-retest reliability of the open field test,as a method for ethology in Kunming mice. Methods The behavior of adult male Kunming mice in the open field test was recorded twice,once for five minutes, with a one-week inter-trial interval. The following parameters were evaluated:number of central squares; number of peripheral squares; percent of central squares; number of horizontal squares; number of rearings; total score; and number of fecal boli. Subsequently,the intraclass correlation coefficient (ICC) and the agreement index (Kappa) were calculated for each of these parameters. Results Both ICC and Kappa for total score( ICC =0.902, P<0.01; Kappa =0.680, P<0.01; r=0.815, P<0.01 ) showed a good reliability and correlation between the test trials. Only ICC for number of central squares ( ICC = 0. 578, P < 0.01 ), number of peripheral squares( ICC =0.615, P<0.01 ) ,percent of central squares(ICC=0.523, P<0.01) ,number of horizontal squares( ICC = 0. 607, P < 0.01 ) and number of rearings ( ICC = 0. 606, P < 0.01 ) indicated a fair reliability between the test trials. Neither ICC nor Kappa for number of fecal boli displayed a significant reliability between the test trials. The difference of these parameters between test and retest, such as number of peripheral squares( t =3.01, P<0.01 ),number of horizontal squares( t = 3.34, P < 0.01 ) and total score( t = 7.86, P < 0.01 ) were significant. Conclusion The parameter,total score for Kunming mice in the open field test,is found to be stable over time, and indicates a good reliability with a one-week inter-trial interval.