1.Accuracy and predictability of ArF laser at 193 nm in corneal refractive surgery
Chinese Journal of Tissue Engineering Research 2007;0(04):-
Excimer laser was found in 1975, and has been used in corneal refractive surgery, which made a great progress and become rapidly developed. ArF laser of 193 nm has high accuracy because it can gasify corneal tissue molecule. Moreover, it does not produce heat effect on tissues surrounding irradiated sites, so not produce adverse effect on corneal structure. At present, excimer laser has been successfully used in corneal radial incision, excimer laser corneal refractive surgery, laser in situ keratomileusis, laser epithelial keratomileusis and laser subepithelial keratomileusis. With increasing understanding of excimer laser and accumulating clinical experience, novel, accurate and predictive excimer laser corneal refractive surgery will be developed.
2.Determination of Trace Elements in Plumbago zeylanica
China Pharmacy 2001;0(11):-
OBJECTIVE:To establish a determination method for trace elements of Plumbago zeylanica. METHODS:Induct- ively coupled plasma emission spectrum (ICP-AES) was used to determine seven trace elements of P. zeylanica, i.e. Cu, Zn,Fe,Ca,Mg,Mn and Sr simultaneously. Se was determined by atomic fluorescence (AFS) method. RESULTS: The RSD ranged from 0.78% to 3.01%(n=5),while the recovery was within 91.9%~105.8%. The result obtained was satisfactory. Se took a large proportion in P. zeylanica, followed by Cu,Zn,Fe,Ca,Mg,Mn,Sr.CONCLUSION: The method is brief, rapid and accurate for the determination of P. zeylanica. The study provide reference for future pharmacological study of P. zeylanica.
4.Keeping pace with time enrichment of pathologic information.
Chinese Journal of Pathology 2008;37(2):73-74
Delivery of Health Care
;
legislation & jurisprudence
;
methods
;
Female
;
Forecasting
;
Health Services for the Aged
;
legislation & jurisprudence
;
supply & distribution
;
Humans
;
Male
;
Medical Informatics
;
Prostatic Intraepithelial Neoplasia
;
pathology
;
Prostatic Neoplasms
;
pathology
;
Time Factors
5.Application of intra-aortic balloon pump in acute myocardial infarction
Xingang WANG ; Ming CHEN ; Yong HUO
Chinese Journal of Interventional Cardiology 2003;0(06):-
Objective To analyze and evaluate the role of IABP in the treatment of patients with acute myocardial infarction.Methods The clinical data of all patients with acute myocardial infarction treated with IABP admitted into the Peking University First Hospital from January 1st 2000 to December 31st 2006 were collected.The treatment effects of IABP were analyzed with statistical methods.Results A total number of 48 patients with acute myocardial infarction were treated with IABP in the past 6 years and 26 of them were presented with cardiogenic shock at the time of admission.The short-term condition was stabilized in 81.3%(39/48) of the patients with IABP treatment which was demonstrated by restoration of stable heart rate and blood pressure,increase in urine volume,symptoms relief and decreasing need of vasoactive drug.The in-hospital mortality was lower in patients received revascularization therapy in additional to IABP compared with patients who had IABP support alone(37.5% vs.93.8%,P
6.Preliminary Study on Serum Fingerprint of Plumbago Zeylanica
Jiahui HU ; Ming YAN ; Shixia HUO
Chinese Journal of Information on Traditional Chinese Medicine 2006;0(11):-
Objective To sieve the bioactive constituents of Plumbago zeylanica, serum pharmacochemistry research was performed. Method Based on the establishment of HPLC fingerprints of Plumbago zeylanica, the constituents absorbed into blood were determined by comparing the HPLC fingerprints of the methanol extracts, medicated serum samples and blank serum sample. Results One compound absorbed into blood was detected, the other might be metabolites of the original constituent. Conclusion The one onstituent absorbed into blood was possible bioactive component of Plumbago zeylanica.
7.Effect of Diagnostic Ultrasound on SOD of Mother and Progeny in Early Pregnancy
Lirong HUO ; Ming YAN ; Jinmin LIU
Journal of Medical Research 2006;0(12):-
0.05).②The animal experiment showed ,in contrast to the control , embryonate rats’ rhodocyte SOD were significantly different after 2 days but no difference before prenatal. ③in contrast with the control , SOD of placenta were significantly different only after 9 days. Conclusions Diagnostic ultrasound in early pregnancy can make SOD change ,but the changes can be reparable.
8.Interventional treatment for CHD with single patent vessel
Ming CHEN ; Yong HUO ; Wei GAO
Chinese Journal of Interventional Cardiology 1996;0(04):-
Objective To summarize the effect and safety of percutaneous coronary intervention (PCI) for CHD in patients with single patent coronary artery. Methods We collected the data of CHD in 10 patients with single patent coronary artery who underwent PCI and analyzed them retrospectively. Results All patients with single patent coronary artery had successful PCI. Symptoms of all the CHD patients had been significantly relieved after PCI. No major adverse cadiac events occurred in hospitalization. Conclusion The data suggest that the patients with single patent coronary artery might be treated with PCI effectively and safely.
9.Anti-proliferation effect of~(103) Pd radioactive stent in micro-porcine model with coronary restenosis
Ming CHEN ; Yong HUO ; Wei SHAO
Chinese Journal of Interventional Cardiology 2003;0(05):-
Objective To investigate the effectiveness, dose-effect and time-effect relationships for inhibiting neointimal proliferation by 103 Pd radioactive stent, and the safety of the radioactive stent. Methods By angiogaphic, morphometric and histopathologic analysis, we compared 1?000 ?Ci, 500 ?Ci and 100 ?Ci 103 Pd stents with non-radioactive stents on 5 weeks and 12 weeks after stenting in a micro-porcine coronary model of restenosis. Results The neointimal areas of 500 ?Ci and 100 ?Ci 103 Pd stents were significantly smaller than control stents. 1?000 ?Ci stents and control stents had similar neointimal areas. The neointimal areas of 500 ?Ci stents were significantly smaller than 100 ?Ci stents. Compared with control stents, 500 ?Ci stents reduced the neointimal areas by 49% and 50% respectively on 5 weeks and 12 weeks after stenting. Compared with 5 weeks after stenting, the effect of inhibiting neointimal proliferation by 100 ?Ci stents was reduced by 56% (32% vs 14%) on 12 weeks. The neointimal areas on both edge of 100 ?Ci stents were significantly larger than control stents. The neointimal areas on both edge of 1?000 ?Ci stents and 500 ?Ci stents were similar with control stents. No evident radiation damage had been found in the experimental animals who had 103 Pd stent. Conclusion There may be an effective dose window for 103 Pd radioactive stent in inhibiting neointimal proliferation. The effect of inhibiting neointimal proliferation was dose dependent. 103 Pd radioactive stent with appropriate activities may effectively, persistently inhibit neointimal proliferation with no adverse radiation sequelae. These results suggest that 103 Pd radioactive stent prevent restenosis. These data may be useful in predicting safe and effective activity for 103 Pd radioactive stent.
10.Effects of stent-based delivery of rapamycin and methotrexate on neointimal formation in a porcine coronary model
Weiting XU ; Yong HUO ; Ming CHEN
Chinese Journal of Interventional Cardiology 1993;0(02):-
Objective To determine the efficacy of stent based rapamycin (Rapa) and methotrexate (MTX) alone or in combination of them to reduce in stent neointimal hyperplasia Rapamycin is a potent immunosuppressive agent that inhibits smooth muscle cell (SMC) proliferation by blocking cell cycle progression Methods Stents were coated with PLGA (poly/lactic co glycolic acid) polymer containing 68-96 ?g Rapa or 250-300 ?g MTX or 58-81 ?g Rapa and 120-170 ?g MTX respectively Twenty five stents (metal, n =8; MTX, n =5; Rapa, n =7; Rapa and MTX, n =5) were implanted in the coronary arteries of 25 pigs Results After 28 days, the mean neointimal thickness was (2 18?1 03) mm 2 in the bare metal stent group; (0 94?0 88) mm 2 in the Rapa group; (0 47?0 24) mm 2 in the combination Rapa and MTX group, (3 93?1 48) mm 2 in the MTX group Compared with metal group the mean neointimal thickness was significantly decresed in Rapa groups and combined group The in stent restenosis was 25% (2/8) in metal group and 80% (4/5) in MTX group after 28 days, and there was no restenosis in the other two groups Conclusion Stent based delivery of Rapa via PLGA polymer can feasibly and effectively reduce in stent neointimal hyperplasia by inhibiting cellular proliferation However there are no effects to reduce in stent neointimal hyperplasia by MTX eluting stents in this study