1.Significance of the expression of MMP-9 and E-cadherin in triple negative breast cancer
Taotao LIU ; Mengqin SHEN ; Dandan WANG ; Yu ZHANG ; Xueqing YANG ; Dabei TANG ; Qingyuan ZHANG
Practical Oncology Journal 2014;(1):19-23
Objective To investigate the expression of matrixmetalloprotein -9(MMP-9)and E-cad-herin in triple negative breast cancer ( TNBC) and its relationship with the clinicopathologic features of TNBC .To analyze the function of MMP -9 and E-cadherin in TNBC .Methods Immunohistochemical method was used to detect the expression of MMP -9 and E-cadherin in 127 cases of TNBC.Results The MMP-9 positive rate was 53.54%and E-cadherin positive grade was 32.28%in TNBC.Expression of MMP-9 was correlated with tumor size(P=0.007),histological grade(P=0.006),TNM stage(P=0.003),lymph node metastasis(P=0.000)and lymph duct invasive(P=0.000).Expression of E-cadherin was correlated with lymph node metasta-sis(P=0.016)and lymph duct invasive(P=0.015).However,they were not correlated with other factors .Con-clusion The expression of MMP -9 and E -cadherin was correlated with invasion and metastasis in TNBC , which could be an important research topic in the future studies .
2.A Novel Electrochemical Enzyme-linked Immunosensor Based on Tyramine Signal Amplification
Mengqin LIU ; Jianhui JIANG ; Yunlan FENG ; Yong HUANG ; Guoli SHEN ; Ruqin YU
Chinese Journal of Analytical Chemistry 2010;38(2):258-262
A novel and highly sensitive voltammetric enzyme-linked immunosensor was developed based on tyramine) oxidation deposition. It was shown that gold nano-particles(colloid Au) could be used as a platform to immobilize antibodies by adsorption. By a sandwich immunossary format with goat-anti-human IgG labled Horseradish peroxidase(HRP) as the second antibody and catalytic amplification by biotin-tyramine, the immunosensor′s) catalytic ability to hydrogen peroxide increased nearly 20 times), the sensor exhibitd a linear response to human IgG in the concentration range from 1.5 μg/L-22 mg/L, and the detection limit was 0.1 μg/L), the regression equation could be expressed as Δi_p(μA) =2.8859c(mg/L)+17.152 with a correlation) coefficient of 0.9872. The immunosensor can be used to quantitatively determine hIgG in the sample) of human serum).
3.The effects of emergency video call system on remote guidance of cardiopulmonary resuscitation implemented by non-medical volunteers
Wanshu QUE ; Jinchuan ZHAO ; Yiming SHEN ; Mengqin CHENG ; Jie LUO ; Haojie WU ; Yu MA ; Jian HUANG
Chinese Journal of Emergency Medicine 2021;30(10):1264-1268
Objective:To explore the feasibility of emergency video call system in remote guidance of non-medical volunteers to implement single person cardiopulmonary resuscitation (CPR).Methods:A scenario of sudden cardiac arrest with a bystander in a public place was created at Clinical Skill Training Center. 60 non-medical volunteers were randomly (ramdom number) divided into video group ( n = 40) and audio group ( n = 20). Volunteers in video group were remote instructed with the smart phone application software (APP) of Emergency Video Call System to implement CPR; the audio group receives remote voice guidance for CPR with a smart phone. The pressing depth, pressing frequency, volume of ventilation and the time of the first compression were compared between the two groups. The video group was divided into 5 subgroups to compare the cardiopulmonary resuscitation effect of 5 different models of smart phones. Ten CPR cycles were observed in each group. Results:the accuracy rate of pressing position in the video group was significantly higher than that in the audio group (91.5% vs 71.35%, P < 0.05); the proportion of pressing depth in the range of 5-6 cm was significantly higher than that in the audio group (62.79% vs. 44.73%, P < 0.05); the average pressing frequency was 100-120 times / min (70% vs. 52%, P < 0.05); the ventilation volume was 500-600 mL / time (18.25% vs. 10.75%, P < 0.05); The proportion of ventilation volume greater than 500ml / min was higher than that of audio group (64.88% vs. 43%, P < 0.05). The first pressing time was longer in the video group than in the audio group (131 s vs. 106 s, P < 0.05). There was no significant difference in the first ventilation time between the two groups (148 s vs. 144 s, P > 0.05). The total pressing pause time in video group was less than that in audio group (122.4 s vs. 164.2 s, P < 0.05). There was no significant difference in the above indicators among the five different models of smart phones in the video group ( P > 0.05). Conclusions:compared with audio remote guidance, video emergency system has obvious advantages in the accuracy of pressing position, pressing depth, pressing frequency, ventilation volume and pressing pause time, but the first pressing time is slightly longer than that of audio group. The popularization and application of the video system is supposed to improve the CPR quality and recovery success rate of non-medical personnel, and facilitated to encourage the first witness to implement CPR.
4.Research on chemical components and biological activities of the iridoids in Morinda genus
Yi SHEN ; Qi ZHANG ; Mengqin LIU ; Yuqiong HE ; Hailiang XIN ; Luping QIN ; Qiaoyan ZHANG
Journal of Pharmaceutical Practice 2020;38(2):110-114
Morinda genus of Rubiaceae has been widely used in medicine at home and abroad. Many parts of Morinda tree are utilized in research, mainly including roots, stems, leaves, branches and seeds. Through the research of online databases, the chemical components and biological activities of the iridoids in Morinda genus were summarized in this paper. Up to now, more than 50 kinds of iridoids have been identified. In addition, more and more studies proved that Morinda iridoids might benefit human via such anti-inflammatory, antinociceptive, anti-oxidation, anti-tumor and bone protection. The theoretical basis was provided for the further development and utilization of the iridoids in Morinda genus.