1.Application of Video Monitoring System in Intensive Care Unit.
Yong QIN ; Lianying GONG ; Jiahui YU ; Mengmeng SHANG
Chinese Journal of Medical Instrumentation 2015;39(6):400-402
The system applies H.264 compression coding technology and uses TCP/IP protocol to transmit data. It transfers the video information, cardio-spectrograms, blood oxygen and blood pressure spectrum to the medical area and the visiting area for families that outside of ICU intensively. The patients' information is transmitted to the medical staffs intensively, then making the relevant backups, so people can avoid many potential medical disputes.
Blood Pressure
;
Data Compression
;
Heart
;
Humans
;
Intensive Care Units
;
Monitoring, Physiologic
;
instrumentation
;
Technology
;
Video Recording
2.Bioeffect of different parameters on four tumor cell lines by ultrasound-mediated microbubble destruction
Dandan SHI ; Jie LI ; Sujuan DUAN ; Lu GUO ; Mengmeng SHANG ; Song NING ; Xiao SUN
Chinese Journal of Ultrasonography 2017;26(7):628-631
Objective To explore the bioeffect of different parameters on 4 cell lines by ultrasoundmediated microbubble destruction.Methods The orthogonal experimental design was used to investigate the effect of three factors on the bioeffects of four cell lines under three levels.Three factors included microbubble concentration,sound intensity,irradiation time.Human breast tumor (MCF-7) cells,ovarian tumor (A2780) cells,liver tumor (Bel7402) cells and thyroid tumor (ARO) cells were exposed to ultrasound in the presence of SonoVue.The cell survival rate was determined by MTT methods and the cell luminosity factor was detected by flow cytometry.Results The optimum parameters for Bel7402 and ARO cell were the same (A2B3C2),and they were different from those from MCF-7 (A3B1C1) and A2780 (A1B3C3) cell.The cell survival rates for 4 cell lines were above 75%,and the cell luminosity factors were different among 4 cell lines.Conclusions The optimum parameters by ultrasound-mediated microbubble destruction for different cell lines are different,and under the optimum parameters the bioeffects of different cell lines are different.
3.The utility of texture analysis in differential diagnosis of medulloblastomas and ependymomas
Ya LI ; Yong ZHANG ; Mengmeng LI ; Jingliang CHENG ; Zhigang SHANG ; Chunxiao BU
Journal of Practical Radiology 2017;33(3):447-450,454
Objective To analyze magnetic resonance images of medulloblastomas and ependymomas by texture analysis method, and evaluate the texture characteristics of two tumors by support vector machine (SVM).Methods 58 tumors were analyzed retro-spectively,including 31 medulloblastomas and 27 ependymomas,which had been confirmed with operation and pathology.Texture analysis was performed onthese tumors.Results The 5 texture parameters extracted from the gray level co-occurrence matrix and at least 3 parameters which had statistical significance between the two different classes of data sets(P<0.05).For all data sets,the variance parameters of gray value of ROI region have statistical significance.The accuracy of SVM test was (86.15±4.16)%,which had remarkable significance between the ependymomas and medulloblastomas.Conclusion The analysis of texture features can pro-vide a lot of quantitative information,and can be a potential method for the differential diagnosis of medulloblastomas and ependy-momas.
4.Diagnostic value of color Doppler twinkling artifact and in urinary calcium stones: an in vitro experiment
Qing LIU ; Jie LI ; Xiao SUN ; Mengmeng SHANG ; Dandan SHI ; Song NING ; Lin CHENG
Chinese Journal of Ultrasonography 2015;24(1):70-73
Objective To investigate the diagnostic value of twinkling artifact in urinary calcium stones.Methods Calcium oxalate monohydrate,hydroxyapatite and whitlockite stone phantoms were prepared and embedded in porcine kidneys for ultrasound scanning.The length and width of twinkling artifact were measured.The intensity of twinkling artifact and the contrast-to-noise ratio (C/N ratio) of acoustic shadowing were recorded and all the data was analyzed statistically.Results All the stone phantoms generated twinkling artifact and acoustic shadowing.The difference of the intensity,length and width of twinkling artifact and the C/N ratio of acoustic shadowing had statistically significant each composition (P <0.01).There was no overlap between 95% confidence interval of the intensity of twinkling artifact for any two compositions,and any two compositions of stones could be differentiated by the intensity of twinkling artifact (P <0.05).The C/N ratio of acoustic shadowing of calcium oxalate monohydrate and whitlockite stone phantoms were higher than those of hydroxyapatite ones (P <0.05).The receiver operating characteristic (ROC) curve displayed that the cutoff value of 1 127 of the intensity of twinkling artifact could be used to diagnose hydroxyapatite stones.The sensitivity,specificity,positive predictive value (PPV),negative predictive value (NPV) and area under the curve (AUC) were 74 %,68 %,69.8%,72.3% and 0.743 respectively.Conclusions Twinkling artifact could be used to differentiate the calcium stones,which will be helpful for clinical treatment.
5.Value of color Doppler twinkling artifact and CT in distinguishing uric acid stones from cystine stones: an experimental study
Xiao SUN ; Jie LI ; Mengmeng SHANG ; Qing LIU ; Dandan SHI ; Song NING ; Lin CHENG
Chinese Journal of Ultrasonography 2015;24(2):164-167
Objective To quantitatively analyze the value of color Doppler twinkling artifact and CT in distinguishing urinary stone composition of uric acid from that of cystine,and to assess the ability of color Doppler twinkling artifact and CT to diagnose urinary stone composition of uric acid.Methods Artificial stones made of uric acid and cystihe were inserted in porcine kidneys respectively.Color Doppler ultrasound and CT scanning were performed in vitro and twinkling artifact videos were recorded.The CT attenuation value,the width and length of twinkling artifact (TAW,TAL) were measured.The color pixels representing twinkling artifact intensity (TAI) were calculated.The differences between artificial cystine and artificial uric acid stones in TAW,TAL,TAI and CT attenuation value were compared.The receiver operating characteristic (ROC) curve was used to assess the ability of TAW,TAL,TAI and CT attenuation value to diagnose urinary stone composition of uric acid.Results The TAW [(4.16 ± 1.54)mm vs (4.97 ± 1.93)mm],TAL[(3.75 ± 1.05)mm vs (5.12 ± 2.51)mm] and TAI [(3 005.50 ± 812.33) vs (5 433.86±2 505.81)] of artificial cystine stones were less than those of artificial uric acid stones while the CT attenuation value of artificial cystine stones [(573.75 ± 110.10)HU vs (364.09 ± 67.28)HU] were greater (P <0.05).The ROC curve was displayed to diagnose urinary stone composition of uric acid,and the area under curve of CT attenuation value was bigger than that of TAI (0.936 vs 0.817,Z =2.308,P =0.021).Combination of color Doppler twinkling artifact and CT value would dramatically increase the diagnostic accuracy to 98%.Conclusions Both color Doppler ultrasound and CT were reliable examinations for distinguishing urinary stone composition of cystine from that of uric acid.Combination of color Doppler ultrasound and CT would be good references to diagnose urinary stone composition of uric acid.
6.Experimental study on preparation and targeting in vitro of nanobubbles with two-fold amount of folate
Sujuan DUAN ; Lu GUO ; Dandan SHI ; Mengmeng SHANG ; Dong MENG ; Xiao SUN ; Benkang SHI ; Jie LI
Chinese Journal of Ultrasonography 2018;27(11):995-999
Objective To investigate the selective targeting ability of a novel folate-modified nanobubbles with two-fold amount of folate [(FOL)2-NBs] . Methods DSPE-PEG2000-AD-(FOL)2with two-fold of folate per DSPE-PEG2000 chain was synthesized and then tested by 1 H nuclear magnetic resonance (1H NMR) . The novel (FOL)2-NBs was prepared using the mechanical shaking method based on lipid-stabilized perfluoropropane . The bubble size was measured by Malvern laser particle size analyzer and the contrast enhancement ability was also detected with imaging machine using a self-made agarose mold . The experiment of selective targeting ability was also carried out in human breast cancer MCF-7 cell with over-expression of folate receptor ( FR) using fluorescence activated cell sorting ( FACS) . Results The result of 1H NMR proved that DSPE-PEG2000-AD-( FOL )2was successfully synthesized ,and the purity reached up to 90% . The novel prepared ( FOL) 2-NBs showed superior contrast enhancement ability with a particle size of ( 286 .87 ± 22 .96) nm . Compared with the conventional NBs ,the novel ( FOL) 2-NBs exhibited improved selective cellular targeting ability proven by FACS . Conclusions A novel nanobubble with improved selective targeting ability is successfully prepared and shows great potential in extravascular imaging and curation in FR overexpressed tumors .
7.Antitumor effect of low-frequency ultrasound combined with autophagy blockade in the mouse model of 4T1 breast cancer
Xiaoxuan WANG ; Mengmeng SHANG ; Xiao SUN ; Lu GUO ; Dandan SHI ; Jie LI
Chinese Journal of Ultrasonography 2022;31(3):260-266
Objective:To investigate the effect of low-frequency ultrasound combined with hydroxychloroquine (HCQ) on the growth and invasion of 4T1 breast cancer in mice.Methods:4T1 cells in logarithmic growth phase were divided into 4 groups: control group, ultrasound group, HCQ group and ultrasound combined with HCQ group. Western blot was performed to detect the effects of ultrasound combined with HCQ on the protein expression levels of autophagy-related proteins LC3, p62 and matrix metalloproteinase 9 (MMP-9). Transmission electron microscopy was used to observe the formation of autophagic vesicles. The cell proliferation and cell viability were determined by EdU and CCK-8. Transwell assay was performed to detect the effect of ultrasound combined with HCQ on the invasive ability of 4T1 cells. Flow cytometry was performed to detect the effect of ultrasound combined with HCQ on the apoptosis of 4T1 cells. The transplantation tumor model of 4T1 breast cancer in BALB/c mice was constructed.The mice were randomly divided into 4 groups ( n=5 for each group), including control group, ultrasound group, HCQ group, ultrasound combined with HCQ group. The tumor volume and mice body weight were evaluated and measured in each group every 2 days. Results:The expression of LC3-Ⅱ and p62 protein levels increased in the ultrasound combined with HCQ group, and intracellular autophagosome accumulation was evident by transmission electron microscopy. In cellular experiments, compared with the other groups, the ultrasound combined with HCQ group showed stronger growth inhibition, significantly decreased cell proliferation rate, decreased expression of MMP-9, and significantly inhibited invasion (all P<0.050). In the in vivo experiments, compared with the control group, the tumor growth rate of all 3 inter vention groups of mice decreased (all P<0.050), and the ultrasound combined with HCQ group had better therapeutic effects than the ultrasound and HCQ groups. The treatment effect of ultrasound combined with HCQ group was better than that of ultrasound and HCQ groups (all P<0.001). Conclusions:The combination of low-frequency ultrasound and hydroxychloroquine could synergistically inhibit tumor cell proliferation, promote apoptosis, and significantly inhibit tumor growth in 4T1 tumor-bearing mice.
8.Application value of two-dimensional shear wave elastography for detecting chemotherapy-induced changes of liver stiffness in postoperative breast cancer patients
Chao JIANG ; Lu GUO ; Dandan SHI ; Mengmeng SHANG ; Xiao SUN ; Jie LI
Chinese Journal of Ultrasonography 2022;31(4):312-317
Objective:To detect the changes of liver stiffness before and after chemotherapy in postoperative breast cancer patients using the two-dimensional shear wave elastography (2D-SWE) technique, and analyze its correlation with liver serum indexs, then discuss the application value of 2D-SWE technique in the quantitative diagnosis for chemotherapeutic liver injury.Methods:Sixty breast cancer patients underwent postoperative chemotherapy in Qilu Hospital of Shandong University from January 2021 to November 2021 were included. Conventional two-dimensional ultrasound, 2D-SWE and the serum tests including alanine aminotransferase(ALT), aspartate aminotransferase(AST), γ-glutamyltransferase(γ-GT), alkaline phosphatase(AKP) were performed before and after chemotherapy, respectively. The medians of ElastQ Imaging stiffness (EQI meds) of the whole liver and different liver segments (S4, S5/S6, S7/S8) before and after chemotherapy were measured and compared. The EQI meds of different liver segments (S4, S5/S6, S7/S8) after chemotherapy were compared. The correlation between EQI med of the whole liver and serum indexes after chemotherapy was analyzed. Results:①Compared with before chemotherapy, the EQI meds of the whole liver and different liver segments after chemotherapy were significantly decreased ( P<0.001, respectively). ②The EQI meds among different liver segments were different after chemotherapy ( F=7.489, P=0.001). Moreover, the EQI meds of S5/S6 and S7/S8 were significantly lower than those of S4 after chemotherapy ( P=0.002, 0.001). ③The EQI med of the whole liver was negatively correlated with ALT, AST, and γ-GT ( r=-0.776, P<0.001; r=-0.656, P<0.001; r=-0.428, P=0.010), while there was no correlation between the EQI med of the whole liver and AKP ( r=-0.146, P=0.267). Conclusions:2D-SWE is expected to be a new, real-time, noninvasive and quantitative method to evaluate the changes of liver stiffness before and after chemotherapy in postoperative patients, thus provides a promising method for the early clinical diagnosis of chemotherapy-induced liver injury in breast cancer patients.
9.Application of Video Monitoring System in Intensive Care Unit
Yong QIN ; Lianying GONG ; Jiahui YU ; Mengmeng SHANG
Chinese Journal of Medical Instrumentation 2015;(6):400-402
The system applies H.264 compression coding technology and uses TCP/IP protocol to transmit data. It transfers the video information, cardio-spectrograms, blood oxygen and blood pressure spectrum to the medical area and the visiting area for families that outside of ICU intensively. The patients’ information is transmitted to the medical staffs intensively, then making the relevant backups, so people can avoid many potential medical disputes.
10.Application of 3D-slicer software to measure renal volume parameters in evaluating renal function of renal transplant donors
Mengmeng ZHENG ; Chunkai DU ; Limin SHANG ; Lei ZHANG ; Wen SUN ; Zhipeng WANG ; Yichen ZHU ; Ye TIAN
International Journal of Surgery 2023;50(12):823-828
Objective:To explore the application value of 3D-slicer software in measuring renal volume parameters of renal transplant donors in evaluating renal function.Methods:The data of 31 renal donors admitted to Beijing Friendship Hospital, Capital Medical University from October 2019 to September 2022 were retrospectively analyzed. Glomerular filtration rate (GFR) were measured by SPECT radioactive dynamic imaging, and renal cortex volume (RCV), renal parenchymal volume (RPV) were measured after 3D reconstruction of urinary enhanced CT based on 3D slicer software. The estimated GFR(eGFR) predicted by creatinine-based GFR estimation equations (C-G equation, modified and simplified MDRD equation) and volume-based GFR estimation equations (Herts equation, Choi equation). Different eGFR were calculated, and the correlation between kidney volume parameters, eGFR equations and measured GFR was analyzed. The deviation, accuracy and consistency between different equations eGFR and measured GFR were analyzed and compared. The measurement data of normal distribution were expressed as mean±standard deviation ( ± s), and t-test was used for inter-group comparison. Measurement data with non-normal distribution were represented by M( Q1, Q3), and non-parametric test was used for comparison between groups. Results:The correlation between different eGFR and measured GFR is poor, and the deviation is small, and with good accuracy and consistency. Except for the weak correlation between the Choi equation eGFR and measured GFR ( r=0.382, P=0.034), there was no significant correlation between eGFR by other equations and measured GFR ( P>0.05). Among them, the deviation between the Herts equation-eGFR and measured GFR was the smallest (0.30 mL·min -1·1.73 m -2), with a 10% coincidence rate (61.29%) and a 30% coincidence rate (96.77%), and the best consistency with measured GFR, with a consistency limit of -28.75 to 29.34 mL·min -1·1.73 m -2. Conclusion:Compared with the laboratory index formula method, the Herts equation has better prediction efficiency in estimating GFR, The measurement of renal volume parameters by 3D slicer software has a certain clinical value in evaluating the renal function of renal donors, which is worthy of further application.