1.Epidemiology and trend forecast of newly diagnosed pulmonary tuberculosis patients in Meishan City , 2014-2019
Hui DENG ; Junying LIU ; Li LIN ; Lidan YANG
Journal of Public Health and Preventive Medicine 2020;31(4):50-53
Objective To understand the epidemiological characteristics of the newly diagnosed pulmonary tuberculosis patients in Meishan City from 2014 to 2019, and to carry out trend prediction and analysis, so as to provide theoretical basis for the formulation of prevention and control strategies. Methods Raw data of newly diagnosed tuberculosis patients in Meishan City from 2014 to 2019 were collected from Meishan Statistical Yearbook. And Excel was used to manage the raw data. The epidemiological characteristics of newly diagnosed pulmonary tuberculosis patients in Meishan City from 2014 to 2019 were analyzed, and the epidemic trend of pulmonary tuberculosis in Meishan City in the next two years was predicted by grey GM(1,1) model. Results From 2014 to 2019, a total of 1 832 smear positive pulmonary tuberculosis cases were reported in Meishan City. The annual average reported incidence rate of smear positive pulmonary tuberculosis was 26.95/100 000. The overall incidence rate of smear positive pulmonary tuberculosis showed a downward trend. Among the 1 832 newly diagnosed tuberculosis cases, the majority were male, aged 31~40 years old, spring onset, township residence and rural residence, farmers and students. The predicted incidence of pulmonary tuberculosis in Meishan City from 2014 to 2019 based on grey GM(1,1) model is basically consistent with the actual incidence, and the predicted incidence of pulmonary tuberculosis in 2020 and 2021 are 27.68/100 000 and 30.25/100 000 respectively. Conclusion The incidence of newly diagnosed pulmonary tuberculosis in Meishan City from 2014 to 2019 has a downward trend in general, while it may increase in the next two years, so the prevention and control measures for high-risk groups, regions and seasons should be strengthened.
2.In vitro bacterial resistance monitoring of urinary tract infectious in female elderly patients
Guangling LIN ; Linxing CHEN ; Meishan LIN ; Hongni GU ; Bo LIU
Clinical Medicine of China 2011;27(3):264-266
Objective To determine the distribution and antibiotics resistance characteristic of pathogens in urinary tract infections in aged female diabetics patients and provide scientific basis for clinicians in selecting effective antibiotics. Methods Pathogenic bacteria, isolated from specimens of 107 elderly female diabetic cases with urinary tract infections, were identified and drug susceptibility tests were performed by VITEK-32 analysator. Results Among all 107 kinds of isolated bacteria,the ratio of gram-negative bacteria was 74. 8% ( 80/107 ), predominated by Escherichiacoli ( accounting for 48. 6% [52/107] ); the ratio of gramposition bacterias was 13. 1% (14/107) and eumycetes was 12. 1% (13/107). In antibiotic resistance analysis,the gram negative bacteria showed higher drug-resistance to the some common-antibiotics, such as ampicililin,cefazolin,cefuroxime-sodium and cefuroxime axetil ( > 70. 0% ), while they were sensitive to imipenem and amikacin( < 10. 0% ). The gram positive bacteria were most sensitive to vancomycin (0%), followed by Linezolid(7.7% ). Conclusion Escherichiacoli were the major pathogenic bacteria in urinary tract infections in aged female diabetic patients, with higher drug resistance. Therefore, drug resistance monitoring should be carried out according to the variety of pathogenic bacteria so as to guide rational use of antibiotics and decrease drug resistance.
3.The analyses on dust pollution of one underground iron mine from 1991 to 2010.
Hou-qin XUN ; Yao-meng XU ; Xiao-ming JI ; Zhi-guo HOU ; Sha-sha WANG ; Guo-hua YU ; Hai-bin YE ; En-ming CHEN ; Mei-lin WANG ; Chun-hui NI
Chinese Journal of Industrial Hygiene and Occupational Diseases 2011;29(10):766-769
OBJECTIVEThe main purpose of this work was to give the evidence of reasonable and feasible dust control measures which will be taken in the future by analyzing the trend of dust concentration from 1991 to 2010 and identifying working faces with the severe dust contamination in one underground iron mine.
METHODSThe data was from routine monitoring between the years 1991 and 2010, which enclosed the total dust concentrations and silica contents. China National Standard of Occupational exposure limits for hazardous agents in the workplace used to judge whether the dust concentration exceeded the National Standard.
RESULTSThe general trend of total dust concentration from 1991 to 2010 was decreased, especially maximum and average levels. The highest exceeding rate was 43.16% in 1993 and the best years were 2009 and 2010, but the exceeding rates were still over 30%. The dust exposure levels varied with different work faces. The mining and supporting were the most severe dust pollution faces which the highest ultra exceeding rates were 51.61% and 51.48% and the maximum exceeding times were 64.6 and 16.4 respectively. The next was constructing face with 40.23% exceeding rate and 24.6 times more than standard.
CONCLUSIONThe trend of total dust concentration from 1991 to 2010 was decreased, but the dust exceeding rate was still high. The strong measures should be taken to control the dust pollution in this iron mine, especially mining and supporting faces.
Air Pollutants, Occupational ; analysis ; Dust ; analysis ; Environmental Monitoring ; Iron ; analysis ; Mining ; Occupational Exposure ; analysis
4.Effects of Compound Danshen Dripping Pills on Ventricular Remodeling and Cardiac Function after Acute Anterior Wall ST-Segment Elevation Myocardial Infarction (CODE-AAMI): Protocol for a Randomized Placebo-Controlled Trial.
Yu-Jie WU ; Bo DENG ; Si-Bo WANG ; Rui QIAO ; Xi-Wen ZHANG ; Yuan LU ; Li WANG ; Shun-Zhong GU ; Yu-Qing ZHANG ; Kai-Qiao LI ; Zong-Liang YU ; Li-Xing WU ; Sheng-Biao ZHAO ; Shuang-Lin ZHOU ; Yang YANG ; Lian-Sheng WANG
Chinese journal of integrative medicine 2023;29(12):1059-1065
BACKGROUND:
Ventricular remodeling after acute anterior wall ST-segment elevation myocardial infarction (AAMI) is an important factor in occurrence of heart failure which additionally results in poor prognosis. Therefore, the treatment of ventricular remodeling needs to be further optimized. Compound Danshen Dripping Pills (CDDP), a traditional Chinese medicine, exerts a protective effect on microcirculatory disturbance caused by ischemia-reperfusion injury and attenuates ventricular remodeling after myocardial infarction.
OBJECTIVE:
This study is designed to evaluate the efficacy and safety of CDDP in improving ventricular remodeling and cardiac function after AAMI on a larger scale.
METHODS:
This study is a multi-center, randomized, double-blind, placebo-controlled, parallel-group clinical trial. The total of 268 patients with AAMI after primary percutaneous coronary intervention (pPCI) will be randomly assigned 1:1 to the CDDP group (n=134) and control group (n=134) with a follow-up of 48 weeks. Both groups will be treated with standard therapy of ST-segment elevation myocardial infarction (STEMI), with the CDDP group administrating 20 tablets of CDDP before pPCI and 10 tablets 3 times daily after pPCI, and the control group treated with a placebo simultaneously. The primary endpoint is 48-week echocardiographic outcomes including left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume index (LVEDVI), and left ventricular end-systolic volume index (LVESVI). The secondary endpoint includes the change in N terminal pro-B-type natriuretic peptide (NT-proBNP) level, arrhythmias, and cardiovascular events (death, cardiac arrest, or cardiopulmonary resuscitation, rehospitalization due to heart failure or angina pectoris, deterioration of cardiac function, and stroke). Investigators and patients are both blinded to the allocated treatment.
DISCUSSION
This prospective study will investigate the efficacy and safety of CDDP in improving ventricular remodeling and cardiac function in patients undergoing pPCI for a first AAMI. Patients in the CDDP group will be compared with those in the control group. If certified to be effective, CDDP treatment in AAMI will probably be advised on a larger scale. (Trial registration No. NCT05000411).
Humans
;
ST Elevation Myocardial Infarction/therapy*
;
Stroke Volume
;
Ventricular Remodeling
;
Prospective Studies
;
Microcirculation
;
Ventricular Function, Left
;
Myocardial Infarction/etiology*
;
Treatment Outcome
;
Percutaneous Coronary Intervention/adverse effects*
;
Heart Failure/drug therapy*
;
Drugs, Chinese Herbal/therapeutic use*
;
Randomized Controlled Trials as Topic
;
Multicenter Studies as Topic
5.Total electric field intensity in workplace of high-voltage direct current converter stations
Guoyong XU ; Lei LIU ; Jianhui LI ; Jiao QING ; Bin LI ; Tianwei LI ; Ruiqin LU ; Hong SHI ; Xinqi LIN ; Danying ZHANG ; Bin XIAO
Journal of Environmental and Occupational Medicine 2023;40(8):931-935
Background The converter stations of high-voltage direct current (HVDC) transmission lines generate special total electric fields. At present, few investigations have been conducted on total electric fields in the workplace of converter stations from an perspective of occupational health. Objective To understand the current situation of total electric field strength in the workplace of converter stations. Methods Using purposive sampling, a calibrated HDEM-1 direct current (DC) total electric field strength measurement system was used to measure the total electric fields of 12 converter stations serving 6 DC lines in Southeast and Southwest China according to the Measurement method for total electric field strength and ion current density of the converter stations and DC transmission lines (DL/T 1089—2008). The results were evaluated according to occupational exposure limits recommended by The limits of electromagnetic environment at ±800 kV UHV DC converter station (DL/T 275—2012), the American Conference of Governmental Industrial Hygienists (ACGIH), and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Results A total of 615 check points were planned, the total electric field strength was 0.05-37.05 kV·m−1, and the median was 10.45 kV·m−1. The total electric field strength of 39 check points (6.3%) exceeded 25 kV·m−1 (the limits of ACGIH and ICNIRP), and the total electric field strength of 12 check points (2.0%) exceeded 30 kV·m−1 (the limit of DL/T 275—2012). There were statistically significant differences in the total electric field strength values and the proportions of exceeding 25 kV·m−1 between the neutral regions and the positive regions and between the neutral regions and the negative regions (P < 0.01). The proportion of total electric field strength exceeding 30 kV·m−1 in the negative regions was higher than that in the positive regions (P < 0.01). There were no significant differences in the total electric field strength of converter stations at different voltage levels and different altitudes (P > 0.05). There were no significant differences in the proportions of total electric field exceeding 25 kV·m−1 and exceeding 30 kV·m−1 in converter stations at different voltage levels and different altitudes (P > 0.05). Conclusion The total electric field in some workplace of converter stations exceeds selected limits. Converter station operators may be exposed to high-strength total electric field for a short time.