1.Risk factors for conjunctival tube erosion in eyes implanted with Ahmed glaucoma valve in a private eye institution in the Philippines.
Jovell Ian M. PEREGRINO ; Edgar U. LEUENBERGER ; Ma. Imelda Y. VELOSO
Philippine Journal of Ophthalmology 2018;43(2):51-59
Objective:
To identify the risk factors for conjunctival tube erosion (CTE) in eyes implanted with Ahmed®
glaucoma valve (AGV) device
Method:
This is a retrospective study conducted at a private eye institution. Medical records of patients who
underwent AGV implantation surgery from January 2004 to December 2013 were reviewed. Eyes with at least 24
months of follow-up and complete records were included. Several variables from the pre-, intra-, and postoperative
periods were collected. The primary outcome was development of CTE after AGV surgery. Univariable logistic
regression and multivariable analysis were employed.
Results:
Forty-six (46) eyes of 45 patients were included in the study. The mean follow-up was 50.2 months
(range: 24-140 months). Eight (8) eyes developed CTE (17.4%). Univariable logistic regression analysis identified
female gender (P =0.064), presence of diabetes (P =0.083), prior intraocular surgeries (P =0.09), and postoperative
use of antiglaucoma medications (P =0.086) to be marginally significant risk factors for CTE. On multivariable
analysis, only female gender (OR=15.4, P =0.033) and diabetes (OR=14.1, P =0.031) were found to be significantly
associated with CTE.
Conclusion
Risk factors for CTE following AGV implantation include female gender and presence of diabetes.
Human
;
Glaucoma