1.Contrast-enhanced ultrasound in pediatric population
Journal of Chinese Physician 2017;19(6):801-803
This article mainly summarized the safety and effectiveness of SonoVue (LUMASON) in pediatric intravenous application for contrast-enhanced ultrasound examination.
2.Ultrasound evaluation value of portal vein stenosis after pediatric liver transplantation
Organ Transplantation 2020;11(6):704-
Objective To investigate the ultrasonographic features and its diagnostic value in portal vein stenosis (PVS) after pediatric liver transplantation. Methods Clinical data of 84 pediatric recipients undergoing liver transplantation who were followed up by routine ultrasound were retrospectively analyzed. According to ultrasound and digital subtraction angiography (DSA) results, all recipients were divided into the normal group (
3.The preparation of sulfur hexafluoride lipid-coated microbubbles
Wei WANG ; Mingde LU ; Xiaoyan XIE ; Huixiong XU ; Lida CHEN ; Luyao ZHOU ; Minju HUANG ; Qin YUAN
Chinese Journal of Ultrasonography 2009;18(4):354-357
Objective To prepare phospholipid-based sulfur hexafluoride gas-filled microbubbles, which were designed for targeting microbubbles. Methods The microbubbles composed of DSPC and mPEG2000-PE were produced by film-sonication method,and were compared with SonoVue. In the physical chemistry characteristics studies, the morphology, particle diameter, concentration, pH value and osmotic pressure were investigated. In the echogenicity studies, contrast harmonic imaging technique was used to investigate the enhancement of vitro water sac and normal rabbit kidney parenchyma. Results The lipid microbubbles were well-distributed, round with air holes. The average diameter of self-made microbubbles and SonoVue were 2.25 μm and 2.50μm respectively. The average diameter of self-made microbubbles and SonoVue distributed from 0.4 μm to 10 μm and 0.2 μm to 10 μm,and 90% were under 6 μm and 8 μm respectively,the concentration were 5 x 108~10 x 108/ml and 1 x I08~5 x 108/ml respectively with a stability of 6 hours. In vitro water sac, the gray scale of self-made lipid microbubbles and SonoVue were 121.67±6.76 and 122.33 ± 4.53 respectively( P>0.05). In normal rabbit kidney parenchyma, the peak video intensity of normal rabbit kidney parenchyma of self-made lipid microbubbles and SonoVue were 72.00 ± 7.21 and 74. 65± 10.93 respectively(P>0.05). Conclusions The lipid microbubbles have satisfactory physical chemistry characteristics and echogenicity.
4.The value of ultrasonic cholangiography with contrast agent SonoVue:primary experience ZHOU Lu-yao,
Luyao ZHOU ; Xiaoyan XIE ; Huixiong XU ; Ming KUANG ; Zuofeng XU ; Xiaoyu YIN ; guangjian LIU ; Mingde Lü
Chinese Journal of Ultrasonography 2008;17(9):763-767
Objective To evaluate the feasilibility of ultrasonic cholangiography(USC)with contrast agent SonoVue in evaluating the obstructive bile duct diseases.Methods Twenty patients with obstructive jaundice(choledocholithiasis in 4,post-operative biliary strictures in 2 and malignant tumors in 14)underwent uhrasound-guided percutaneous transhepatic cholangiodrainge drainage(PTCD).Afterward,USC with contrast agent SonoVue administrated from the PTCD tube and percutaneous transhepatic cholangiography(PTC)were carried out in each patient.By using the surgical or PTC findings as reference standard,accuracy of USC in determining the obstructive level and cause of bstructive was evaluated.Results ①The visualization of contrast agent SonoVue was successfully obtained in all 20 patients,three order of bile duct was visualized in 19 patients.The visualization of the ultrasound contrast agent persisted more than 6 min.There was no side effect occurred during the procedure and no uncomfortable complaint after the procedure.②USC determined correctly in 18 cases.Compared with surgical or PTC findings,the accuracy of USC in determining obstructive levels was 90.0%(18/20),and the accuracy in determining the obstructive cause was 85.0%(17/20).Conclusions As a new and safe technique for cholangiography,USC is comparable to PTC in displaying the intrahepatic bite duct and determining the obstructive levels in patients with obstructive jaundice.
5.Classifying of hilar cholangiocarcinoma: a comparison study between percutaneous ultrasonic cholangiography and percutaneous transhepatic cholangiography
Luyao ZHOU ; Xiaoyan XIE ; Huixiong XU ; Zuofeng XU ; Keguo ZHENG ; Ming KUANG ; Peifen CHEN ; Mingde Lü
Chinese Journal of Ultrasonography 2010;19(12):1047-1050
Objective To evaluate the accuracy and utility of percutaneous ultrasonic cholangiography in Bismuth staging of hilar cholangiocarcinoma. Methods Thirty patients who underwent surgery and obtained pathologic diagnosis of hilar cholangiocarcincoma were perspectively ruled in this study. All patients with hilar obstruction underwent baseline ultrasound (BUS), percutaneous ultrasonic cholangiography (PUSC) and percutaneous transhepatic cholangiography(PTC) respectively. Taking operative findings as reference standard,the accuracy of the three imaging modalities in staging of hilar cholangiocarcinoma was compared. Results Among 30 patients, the accuracy of classification among BUS, PUSC and PTC was 23.3 % (7/30), 73.3 % ( 22/30 ), 73.3 % (22/30), respectively. There was statistically significant difference between BUS and PUSC, but the difference between PUSC and PTC was not statistically significant.Conclusions As a new technique for cholangiography, PUSC expands the application of ultrasound in evaluating hilar cholangiocarcinoma and is comparable to PTC in classifying hilar cholangiocarcinoma by Bismuth classification.
6.Study of the influent factors and reconstructing condition for the virtual endoscopy technique Fly-Thru (FT) in bile duct model in vitro
Xiaoer ZHANG ; Ming XU ; Wei WANG ; Guangliang HUANG ; Luyao ZHOU ; Xiaoyan XIE
Chinese Journal of Ultrasonography 2015;24(10):902-906
Objective To investigate the factors affecting Fly-Thru (FT) and the best reconstruction conditions in a bile duct model.Methods The bile duct model was made with corn powder and rubber pipes.FT data of bile duct in vitro were acquired with a 3-dimensional probe of Toshiba Aplio 500,and the data were reconstructed offline in Fly-Thru workstation.Two US doctors assessed the FT images in three degrees.Results The images were divided into good,moderate and poor groups with corresponding score 3,2,1.Of 162 images,72 were rated as grade 1,57 as grade 2 and 33 as grade 3.According to x2 analysis,the diameter,scanning way,and Filter were brought into multinomial regression,then the scanning way was found to be correlated to FT images quality as well as filter (likelihood ratio =87.598,294.290,x2 =9.492,313.722,respectively,P <0.01).Best images of FT can be acquired by transverse scanning,reconstructing in Filter =3,gain =5(0,dynamic range (DR) =50 and threshold ranging 40-90.Conclusions Best FT images in the model could be achieved by scanning in short-axis,and reconstructing the data in Filter =3,gain =50,DR =5(0 and threshold ranging 40-90,which would be basic information for advanced clinic study.
7.Ultrasound-guided percutaneous ablation treatment for current hepatoblastoma: initial single-center experience
Pengliang LI ; Jia LUO ; Xiaoer ZHANG ; Baoxian LIU ; Luyao ZHOU ; Guangliang HUANG ; Quanyuan SHAN ; Xiaoyan XIE
Journal of Chinese Physician 2017;19(6):813-816
Objective To summarize the first experience with ultrasound-guided percutaneous ab lation treatment (PAT) for recurrent hepatoblastoma (HB) after liver resection in children.Methods From August 2013 to April 2015,PAT was used to treat 6 children with a total of 9 recurrent HB,including 5 patients with 8 tumors in the liver and 1 patient with 1 tumor in the lung.The mean size of ablated tumors was (1.5 ± 0.8) cm,and the tumor size range was 0.7 cm to 3.1 cm.Results Four patients were performed percutaneous radiofrequency ablation (RFA) for recurrent HB;and 2 patients were performed percutaneous ethanol injection (PEI).Ablation success was achieved in all patients (6/6,100%).The complete ablation rate after the first ablation session was 88.9% (8/9) on a tumor-by-tumor basis.Only 1 patient developed a fever with temperature > 39 ℃;it was resolved by conservative therapy.During the follow-up period of 5-30 months,3 patients died to tumor progression.The 1-and 2-year overall survival rates after ablation were 83.3% and 41.7%,respectively.Conclusions PAT is a safe and promising therapy for children with recurrent HB after liver resection,and further investigation in large-scale randomized clinical trials is required to determine its role in the treatment of this disease.
8.Detection of EGFR gene mutation in periphral blood of NSCLC patients in Yunnan by Super-ARMS and its clinical significance
CAI Jingjing ; LI Hongsheng ; SHEN Zhenghai ; MA Luyao ; LI Quan ; DU Yaqian ; LIU Junxi ; WANG Xiaoxiong ; GUO Yinjin ; ZHOU Yongchun
Chinese Journal of Cancer Biotherapy 2019;26(12):1350-1355
Objective: To detect the mutation of epidermal growth factor receptor (EGFR) gene in peripheral blood of non-small cell lung cancer (NSCLC) patients in Yunnan area with Super-ARMS, and to explore its correlation with clinicopathological characteristics. Methods: A total of 222 blood samples from patients with NSCLC were collected between January 2017 to December 2018 in the Molecular Diagnostic Center of Yunnan Cancer Hospital. The EGFR gene mutation in peripheral blood samples was detected by SuperARMS, and the relationship between EGFR gene mutation and clinicopathological features was analyzed. Meanwhile, the independent risk factors influencing EFGR mutation were also analyzed. Results: In the peripheral blood of 222 NSCLC patients, there were 81 cases (36.5%) with EGFR gene mutation. Among them, exon 19 deletion and L858R gene point mutation were the most common (75.3% of total mutation); female patients had a higher mutation rate than male patients (45.9% vs 27.0%); patients <60 years old had a higher incidence of mutation than patients≥60 years old (43.2% vs 28.8%) (P<0.05 or P<0.01); moreover, patients with no history of smoking, no history of radical surgery, adenocarcinoma, advanced stage and no history of chemotherapy had higher incidence of EGFR mutation (43.9% vs 21.6%, 39.2% vs 21.2%, 43.9% vs 4.8%, 39.7% vs 23.3% and 44.0% vs 23.5%) (P<0.05 or P<0.01). Multivariate logistic analysis showed that young, no smoking history, adenocarcinoma and no surgical history were independent risk factors for EGFR gene mutation (all P<0.01). Conclusion: In the peripheral blood of patients with NSCLC in Yunnan, the mutation rate of EGFR gene is higher in patients with age<60 years old, adenocarcinoma and non-smoking. Super-ARMS method is more sensitive in the detection of EGFR mutation in peripheral blood of lung cancer patients.
9.Recent advance in relationship between migraine and cardiovascular diseases
Luyao ZHOU ; Bin LI ; Lei ZHANG ; Jiasi LI
Chinese Journal of Neuromedicine 2022;21(12):1286-1289
Migraine is one of the most common primary headache with high disability rate and heavy disease burden. Cardiovascular diseases are common comorbidities in migraine patients; different cardiovascular diseases have different correlations with migraine. For some cardiovascular events with poor prognosis, timely discovery and preventive measures can effectively help to avoid the adverse events. The article illustrates the associations between different cardiovascular diseases and migraine to improve the clinician's attention to such patients.
10.Application of contrast-enhanced ultrasonography in pediatric abdominal disease
Quanyuan SHAN ; Xiaoyan XIE ; Huadong CHEN ; Hong JIANG ; Xiaohua XIE ; Luyao ZHOU
Chinese Journal of Ultrasonography 2018;27(1):36-42
Objective To investigate the security,applicability and diagnostic capacity of intravenous contrast-enhanced ultrasound (CEUS) in a pediatric population. Methods A total of 53 pediatric patients (8 months to 18 years old) received 66 intravenous applications of ultrasound contrast agent SonoVue.Side effects were documented.Histology,reference imaging or clinical diagnosis were compared with CEUS diagnostic results. Results Adverse effects occurred in 1/66 applications (1.5% ). For 44 focal liver lesions,the sensitivity was 100%,the specificity was 95.65%,the positive predictive value was 95.45% and the negative predictive value was 100%.The diagnostic accuracy was 97.73%.All 22 other lesions were diagnosed correctly.Conclusions It is safe and feasible to use intravenous CEUS in children.CEUS is worthy of promotion in pediatric patients with abdominal diseases.