1.Risk factors influencing cannulation success rate of hands-on training of endoscopic retrograde cholangiopancreatography
Liyue ZHENG ; Yanglin PAN ; Hui LUO ; Xuegang GUO
Chinese Journal of Digestive Endoscopy 2017;34(4):269-273
Objective To investigate risk factors decreasing cannulation success rate of trainees receiving hands-on ERCP training and to improve thelevel of ERCP training.Methods Clinical data of 1 193 ERCP cases involved in training in Xijing Hospital of Digestive Disease from December 2012 to December 2014 were retrospectively analyzed.Multivariate logistic regression analysis was performed to investigate the risk factors influencing cannulation success rate of trainees.Results There were 1 165 and 28 patients undergoing common biliary duct (CBD) cannulation and pancreatic duct(PD) cannulation respectively.The success rate of CBD cannulation by trainees was 58.5%(681/1 165)and the overall success rate was 97.9%(1 140/1 165).PD cannulation success rate by trainees was 39.3% (11/28) and the overall success rate was 89.3% (25/28).The overall complication incidence was 8.0% (96/1 193)and the incidence of post-ERCP pancreatitis was 4.4%(53/1 193).Multivariate logistic regression analysis showed that the selective cannulation by trainees was more likely to fail in patients with malignant biliary stricture(OR =0.44,95%CI:0.28-0.67,P<0.01),benign or undetermined biliary stricture(OR =0.32,95% CI:0.17-0.60,P< 0.01),suspected sphincter of Oddi dysfunction(SOD) (OR =0.28,95% CI:0.16-0.47,P< 0.01),coexisting hypertension (OR =0.65,95 % CI:0.44-0.96,P<0.05),RDW ≥ 48 fL (OR =0.69,95% CI:0.51-0.92,P< 0.05),PLT< 100 × 109/L (OR=1.68,95%CI:1.05-2.71,P<0.05).Conclusion Biliary stricture,suspected sphincter of Oddi dysfunction,coexisting hypertension,abnormal RDW and PLT were independent risk factors influencing cannulation success rate by trainees during hands-on ERCP training.
2.Effects of cannulation time on post-endoscopic retrograde cholangiopancreatography pancreatitis
Shengye YANG ; Xiangping WANG ; Rongchun ZHANG ; Liyue ZHENG ; Xiaoyang GUO ; Yanglin PAN ; Xuegang GUO
Chinese Journal of Digestive Endoscopy 2017;34(4):250-253
Objective To analyze the risk factors of post-ERCP pancreatitis (PEP) and to evaluate the relationship between cannulation time and PEP.Methods The data of cannulation time in 1 625 patients who underwent ERCP from 2010 to 2012 were retrospectively studied.The risk factors associated with PEP were analyzed by univariate and multivariate Logistic regression analysis.The effect of different cannulation time on PEP was evaluated.Results The incidence of overall PEP was 4.6% (75/1 625) including 4.1% (67/1 625)of mild and 0.5% (8/1 625)of moderate-to-severe.Univariate analysis revealed that diabetes mellitus (P =0.02),choledocholithiasis (P =0.02),malignant biliary stenosis (P =0.007),duodenal stenosis (P =0.029),precut (P<0.01),cannulation time ≥ 8 min (P<0.01),blood platelet count ≥ 180× 109/L(P =0.089),alkaline phosphatase ≥ 120 U/L (P =0.083) and total bilirubin ≥ 17.1 μmol/L (P =0.094)were associated with PEP.Multivariate analysis revealed that precut (OR=1.93,95%CI:1.10-3.39,P=0.022),cannulation time ≥8 min (OR =3.50,95%CI:2.00-6.13,P<0.01) and duodenum stenosis (OR=2.92,95%CI:1.08-7.86,P=0.034) were independent risk factors of PEP.Within 30 min of cannulation,longer cannulation time was accompanied with higher PEP rate.Conclusion The cannulation time is an independent risk factor of PEP.Overall PEP is increased when cannulation time is more than 8 min.
3.Protective Effects of Tilianin on Brain Tissue in Cerebral Ischemia-reperfusion Injury Model Rats
Liyue MA ; Cheng ZENG ; Ruifang ZHENG ; Wen JIANG ; Chenghui HE ; Jianguo XING
China Pharmacy 2018;29(20):2805-2810
OBJECTIVE:To study the effects of tilianin(TIL)on brain tissue in rats with cerebral ischemia-reperfusion injury. METHODS:Totally 120 male SD rats were randomly divided into sham operation group(0.9% sodium chloride solution),model group(0.9% sodium chloride solution),nimodipine group(32 mg/kg)and TIL low-dose and medium-dose,high-dose groups(4, 8,16 mg/kg),with 20 rats in each group. The rats were given relevant medicine intragastrically,once a day,for consecutive 7 d. 15 min after last medication,cerebral ischemia-reperfusion injury model was established by reforming suture-occluded method. The neurological deficit score in rats were evaluated, and percentage of cerebral infarction volume of rats was determined. Histopathological changes of brain tissue were observed by HE staining. The activities of SOD,CAT and LDH,MDA content in cerebral tissue of rats were determined. The expression of calcitonin gene-related peptide(CGRP)and peripheral vascular endothelial growth factor receptor 2 (VEGFR2) protein were determined by Western blot assay. RESULTS:Compared with sham operation group,neurological deficit score and percentage of cerebral infarction volume of model group were increased significantly(P<0.01);the nerve cells in brain tissue were significantly reduced and the interstitial edema was obvious. SOD and CAT activities were decreased significantly,LDH activity was increased significantly,MDA content was decreased significantly,protein expression of CGRP and VEGFR2were increased significantly(P<0.05 or P<0.01). Compared with model group,neurological deficit score of nimodipine group,TIL medium-dose and high-dose groups were decreased significantly;percentage of cerebral infarction volume was decreased significantly (P<0.05 or P<0.01);above pathological conditions of cerebral tissue in rats were relieved significantly;SOD and CAT activities were strengthened significantly,MDA content and LDH activities were decreased significantly,protein expression of CGRP and VEGFR2were increased significantly (P<0.05 or P<0.01). CONCLUSIONS: TIL has certain protective effects on cerebral ischemia-reperfusion injury model rats,and its mechanism may be related to the up-regulation of CGRP and VEGFR2expression.
4.Evaluation of the performance of systems for whole blood C-reactive protein detection: a multi-center study
Juan CHENG ; Huaiyuan LI ; Haipeng LIU ; Yuxin WANG ; Jin XU ; Shangyang SHE ; Wei QU ; Yidong WU ; Guixia LI ; Junmei YANG ; Liya MO ; Yun XIANG ; Jiangwei KE ; Liyue KUI ; Lei ZHENG ; Hongbing CHEN ; Zhili YANG ; Xin LYU ; Hong ZHANG ; Zhenhua TANG ; Lijuan MA ; Hongquan LUO ; Xiangyang LI ; Wenli ZHANG ; Hui JIA ; Huiming YE ; Lijun TIAN ; Qiuhui PAN
Chinese Journal of Laboratory Medicine 2021;44(7):633-643
Objective:To explore the performance of the commonly used whole blood C-reactive protein (CRP) detection systems and give related recommendation on the performance requirements of detection systems.Methods:A total of 7 540 venous blood samples from 26 maternal, child and children′s hospitals were collected to conduct this multi-center study on the analytical performance of 5 commonly used whole blood CRP detection systems from March to April in 2019. The blank check, carryover, repeatability, intermediate precision, linearity, sample stability, influence of hematocrit/triglyceride/bilirubin, comparison with SIEMENS specific protein analyzer and trueness were evaluated. The 5 systems included BC-5390CRP autohematology analyzer, AstepPLUS specific protein analyzer, Ottoman-1000 Automated Specific Protein POCT Workstation, i-CHROMA Immunofluorometer equipment Reader and Orion QuikRead go detecting instrument. The 5 systems were labeled as a, b, c, d and e randomly.Results:Within the 5 systems, all values of blank check were less than 1.00 mg/L, the carryovers were lower than 1.00%. The repeatability of different ranges of CRP concentrations including 3.00-10.00, 10.00-30.00 and>30.00 mg/L were less than 10.00%, 6.00% and 5.00%, respectively, and the intermediate precision was less than 10.00%. The linearity correlation coefficients of the 5 systems were all above 0.975, while the slope was within 0.950-1.050. Whole blood samples were stable within 72 hours both at room temperature (18-25 ℃) and refrigerated temperature (2-8 ℃). The CRP results were rarely influenced by high triglyceride or bilirubin, except for the immmunoturbidimetric test based on microparticles coated with anti-human CRP F(ab) 2 fragments. When triglyceride was less than 15.46 mmol/L, the deviation of CRP was less than 10.00%. When bilirubin was less than 345.47 μmol/L, the deviation of CRP was less than 10.00%. CRP was more susceptible to Hct on the systems without Hct correction. The deviation of CRP between different Hct dilution concentration and 40% dilution concentration can reach as high as 67.48%. The correlation coefficients ( r) of 5 systems were all more than 0.975 in the range of 0-300.00 mg/L compared with Siemens specific protein analyzer. All systems passed the trueness verification using the samples with specified values of 12.89 and 30.60 mg/L. Conclusion:The performance of 5 systems can basically meet the clinical needs, but it is suggested that the whole blood CRP detection system without automatic Hct correction should be modified manually.