1.The research on quality control parameters detection of neonatal jaundice treatment cases
Qi WANG ; Linxiang HE ; Taishi ZHENG
China Medical Equipment 2016;13(9):42-44,45
Objective: Through researching the quality control parameters detection of neonatal jaundice treatment cases, we can control the quality of treatment cases and preventive maintenance to make sure the therapy to newborn is effective and safe. Methods:Using INCU portable analyzer and BiliBlangket Light MeterII blu-ray irradiation apparatus to respectively test the temperature control parameters and the intensity of blue light phototherapy of the jaundice treatment cases, a lot of research data can be acquired. Results:On the base of researching the quality control parameters detection of neonatal jaundice treatment cases (30 sets in total), we can control the quality of treatment cases smoothly. Through these tests, we can fix the medical equipments which cannot pass the detections. Conclusion:The research on the quality control parameters detection of neonatal jaundice treatment cases makes the preventive maintenance and quality control quick and effective to ensure the treatment effect and safety for the neonatal.
2.A comparative study of difference internal fixation methods for calcaneal fracture
Xiaojing HUANG ; Linxiang WANG ; Xiongbai ZHU ; Xin CHEN
Chinese Journal of Postgraduates of Medicine 2013;36(35):35-38
Objective To observe the therapeutic effect of titanium plate and Kirschner wire system for treatment of calcaneal fracture.Methods The data of 189 patients with calcaneal fracture treated with operation were retrospectively studied,of which 102 patients of calcaneal fracture were treated with titanium plate fixation (titanium plate group),87 patients were treated with Kirschner wire system (Kirschner wire group).The operative time,blood loss,postoperative complication,healing time,before and after treatment Bohler angle,Gissane angle and middle calcaneal width,and Maryland foot function score were observed.Results The patients of the 2 groups were observed with 12-36 (24.0 ± 9.5) months follow-up.The operative time and blood loss in Kirschner wire group were significantly lower than those in titanium plate group [(42.3 ± 12.5) min vs.(67.5 ± 23.1) min and (137.7 ± 42.8) ml vs.(245.0 ± 55.6) ml],there were statistical differences (P < 0.05).The Bohler angle,Gissane angle and middle calcaneal width in the 2 groups after treatment were significantly better than those before treatment [titanium plate group:(32.80 ± 6.35)° vs.(7.81 ± 8.75)°,(130.42 ±6.93)° vs.(175.80 ± 6.05)°,(30.77 ± 3.56) mm vs.(42.60 ±5.24) mm; Kirschner wire group:(30.11 ±4.91)° vs.(9.54 ±8.90)°,(132.89 ±9.54)° vs.(173.11 ±9.05)°,(32.00 ± 4.18) mm vs.(42.78 ± 4.96) mm],there were statistical differences (P< 0.05).The excellent rate of Maryland foot function score after treatment in titanium plate group was significantly higher than that in Kirschner wire group [92.2% (94/102) vs.81.6% (71/87)],there was statistical difference (P < 0.05).Therewere 6 cases appeared infection of incisional wound in titanium plate group,there was no complication in Kirschner wire group,there was statistical difference (P < 0.05).Conclusions Titanium plate and Kirschner wire system are the commonly used methods in treatment of calcaneal fractures,each has its advantages and disadvantages,titanium plate has long time operation,much blood loss and prone to infection,but the excellent rate is higher.Also note that the incision location,restoration and reconstruction of calcaneal anatomy subtalar joint.
3.Experimental research of covered stent implanted in canine hepatic artery
Bing ZHOU ; Linxiang LIU ; Minghua LI ; Yongli WANG ; Yongde CHENG
Journal of Interventional Radiology 2006;0(09):-
50%) of the stent at 2 weeks follow-up,so did 3 cases at 12 weeks follow-up,and the total stenosis rate was 37.5% and 5 cases manifested full endothelialization(3 different locations of the sample all manifested full endothelialization) ,3 cased manifested partial endothelialization(at least 1 location of the sample didn't show full endothelialization) ,and the two terminal parts were easier to get endothelialization than the central part.Before and after the stent implantation,hepatic function of all cases didn't demonstrate any obvious changes.Conclusions Balloon-expandable covered stent can be implanted in canine hepatic artery successfully,with good apposition ability,full endothelialization,and no influence on hepatic function.
4.Application of covered stent in peripheral vessels
Xiqi ZHU ; Linxiang LIU ; Yongde CHENG ; Yongli WANG ; Bing ZHOU
Journal of Interventional Radiology 2006;0(09):-
The application of covered stent in vascular malformation such as aneurysm,pseudoneurysm(PSA) ,arteriovenous fistula(AVF) has outcome to an encouraging result.Recently,it has also been effectively used for PTA,TIPS,traumatic lesions of peripheral vessels,and pseudoneurysm of dialysis grafts,etc.But there still remain some issues on the restenosis and endothelialization after the performance with covered stent.This review will pay attention to them.
5.Application of phosphates and phosphonates prodrugs in drug research and development.
Xun JI ; Jiang WANG ; Lei ZHANG ; Linxiang ZHAO ; Hualiang JIANG ; Hong LIU
Acta Pharmaceutica Sinica 2013;48(5):621-34
Based on the character of the molecular structure, the prodrugs of phosphates and phosphonates were divided into two categories. The first is the drug which contained the phosphate group, introducing protected groups to increase lipophilicity and improve bioavailability. The other one is the drug which had no phosphate group, introducing the phosphate group into molecules to enhance the solubility, regulate the distribution coefficient and enhance the drug-like property. This review focuses on the application of phosphates and phosphonates in drug research and development based on improvement of physico-chemical property, drug safety and the pharmacokinetics.
6.Transcatheter radiofrequency ablation under the guidance of three-dimensional mapping for the treatment of complex cardiac arrhythmias
Lang HONG ; Hong WANG ; Hengli LAI ; Qiulin YING ; Zhangqiang CHEN ; Linxiang LU ; Yun QIU ; Chengwei XIAO
Journal of Interventional Radiology 2010;19(2):123-126
Objective To investigate the effectiveness and safety of transcatheter radiofrequency ablation guided by a three-dimensional mapping system (Ensite or Carto) for the treatment of complex cardiac arrhythmias. Methods A cohort of 123 consecutive hospitalized inpatients during the period from February 2006 to December 2008 were selected for this study. These patients suffered from various arrhythmias, including paroxysmal atrial fibrillation (n=58). Persistent or permanent atrial fibrillation (n=10), atrial flutter (n=13), atrial tachycardia (n=12) and ventricular tachycardia or frequent ventricular premature beats (n=30). Transcatheter radiofrequency ablation for arrhythmias was performed under the guidance of an EnSite3 000/NavX or Array mapping system in 80 cases, and under the guidance of a CARTO mapping system in the remaining 43 cases. Results Successful ablation of arrhythmias was obtained by single operation in 106 cases(86.18%). Including 59 cases with atrial fibriUation,11 cases with atrial flutter, 10 cases with atrial tachycardia, and 26 cases with ventricular tachycardia or premature ventricular beat. Ablation procedure was carried out and was successful in 10 cases with a successful rate of 94.31%, including 5 cases with atrial fibrillation. 1 case with recurred atrial flutter, 1 case with recurrent atrial tachycardia, and 3 cases with ventricular tachycardia or premature ventricular beat. After operation, complications occurred in 6 cases, including cardiac tamponade in 4 cases, distal embolism of the left anterior descending coronary artery in 1 case, and pulmonary embolism in 1 case. Conclusion Three-dimensional mapping system can clearly and stereoscopically display the cardiac structures. Therefore, this technique is of great value in guiding the transcatheter radiofrequency ablation for complex arrhythmias, in improving the success rate of ablation and in increasing the safety of the procedure.
7.Synthesis and antitumor activity of S-hexyl(heptyl) substituted ethanethioate derivatives.
Jiachen WEN ; Tao JIANG ; Yu BAO ; Xianjun LIN ; Wanqiao WANG ; Dan LIU ; Linxiang ZHAO
Acta Pharmaceutica Sinica 2014;49(3):352-8
To simplify the macrocyclic fragment and to modify the zinc binding group of the natural product apicidin, two series of S-hexyl (heptyl) ethanethioate derivatives were designed and synthesized. Twenty-six compounds were synthesized and confirmed with 1H NMR, IR, MS and HR-MS spectrum, which were not reported. Take vorinostat as control, their antiporliferative activities against cancer cell lines, MCF-7 and HL-60, were tested with MTT assay or trypan blue staining method. Generally in both series it was found that, the chiral carbon atom at 7 position is not necessary, compounds II-1, II-3, II-6 and II-13 showed good activity on HL-60 cells in vitro, with the IC50 values less than 10 micromol x L(-1). II-7 and II-8 showed stronger activity against MCF-7 than Vorinostat, with the IC50 of 3.19 and 6.29 micromol x L(-1), respectively.
8.Allogeneic peripheral blood stem cell transplantation combined with bone marrow transplantation for malignant hematologic diseases
Xinsheng XIE ; Dingming WAN ; Hui SUN ; Ling SUN ; Linxiang LIU ; Guiju WANG ; Zhongxing JIANG ; Shaoqian CHEN ; Yuandong CHENG ; Shaojun LIU ; Dianbin ZOU
Journal of Leukemia & Lymphoma 2009;18(11):657-658
Objective To observe curative effect and clinical outcome in 30 recipients undergoing allogcneic peripheral blood stem cell transplantation (PBSCT) combined with bone marrow transplantation (BMT). Methods 30 patients with a median age of 32.6 years underwent allo-HSCT, of which 11 patients with AML, 14 patients with ALL, and 5 patients with CML They all have a HLA-identical sibling. PBSCswere mobilized with G-CSF. Three hundreds milliliter bone marrow blood was transplanted to the patients on the day that the PBSC was transplanted. Amended Bu/Cy was used as the conditioning regimen. MTXcombined with CsA and MMF was used as GVHD prophylaxis. Results A median number of mononuclear cells of (5.13±2.6)x10~8/kg recipient's weight was collccted from peripheral blood, and (1.3±0.6)x10~8/kgrecipient' s weight from bone marrow blood. Engraftment of neutrophils and platelets was achieved at a median of (12.1±3.25) days and (14±5.33) clays respectively. Ⅰ - Ⅱ acute GVHD occurred in 40.0 % cases,Ⅲ - Ⅳ acute GVHD occurred in 3.3 % cases, and chronic GVHD developed in 43.3 % cases. Severe cGVHD developed in 3.3% cases. The 2 years disease free survival rate (DFS) by the day of transplantation was 72.0 %. Conclusion PBSCT combined with BMT was effective to cure leukemia. The results also suggested that PBSC recipients had an lower incidence of aGVHD and cGVHD as compared with previous reports.
9.Supraglottic laryngeal carcinoma resection by radiofrequency coblation under a multifunctional opener in four cases and literature analysis
Yungang WU ; Linxiang MA ; Caihua WANG ; Hui ZHANG ; Yufeng ZHAO ; Juxing SUN ; Xinxin YANG
Chinese Journal of Primary Medicine and Pharmacy 2021;28(10):1501-1505
Objective:To investigate the efficacy and feasibility of radiofrequency resection of supraglottic laryngeal carcinoma under a multifunctional opener.Methods:The clinical data of four cases of supraglottic laryngeal carcinoma (type T1N1M0 in two cases, T2N1M0 in one case, and T1N0M0 in one case) who received treatment in the Affiliated Hospital of Jining Medical University during January-June 2019 were retrospectively analyzed. Radiofrequency resection of supraglottic laryngeal carcinoma under a multi-functional opener combined with bilateral neck II-IV region lymph node dissection was performed. Swallowing, breathing and phonation were observed and analyzed based on references.Results:Among the four cases, two cases had a normal diet at 3 days after surgery, one case had a normal diet at 7 days after surgery, and one case had a normal diet at 16 days after surgery. Tracheotomy was not performed in any case. After surgery, breathing and speech communication were not affected.Conclusion:Radiofrequency surgery under a multifunctional opener can be used for treatment of early supraglottic laryngeal cancer. It is an effective treatment with minimal trauma, mild postoperative pain and promotes the early recovery of normal swallowing function.
10.The value of contrast-enhanced CT and MR DWI in differentiating between autoimmune pancreatitis and pancreatic carcinoma
Shuai REN ; Wenjing CUI ; Jingya CHEN ; Hui LI ; Linxiang LIU ; Zhongqiu WANG
Journal of Practical Radiology 2018;34(5):694-697,701
Objective To investigate the diagnostic value of contrast-enhanced CT and MR diffusion-weighted imaging (DWI) in differentiating autoimmune pancreatitis (AIP) from pancreatic carcinoma (PC).Methods Twelve patients with AIP (AIP groups) and 15 patients with PC (PC groups) were included in this study.Contrast-enhanced CT and DWI were performed in all patients.The manifestations of the pancreatic lesions,pancreatic duct and bile duct were observed.The CT attenuation values and the apparent diffusion coefficient (ADC) values of the lesions were calculated.Frequencies of the CT manifestations,and the mean CT attenuation values,and the ADC values were compared between the two groups.Results Most of the AIP showed diffuse enlargement,sausage shape,peripancreatic capsule,penetrating sign of pancreatic duct and thickness of the bile duct.The frequencies of the findings mentioned above were significantly different between AIP and PC (P<0.05).The CT attenuation values of the lesions,and the rate of lesions' CT attenuation values to livers' in 3 phases of contrast enhanced CT were significantly different between AIP and PC (P<0.05).The ADC values of AIP were significantly lower than that of PC (P<0.05).Conclusion The changes of morphology of pancreas,pancreatic and bile duct may facilitate in differentiating AIP from PC.Quantitative analysis of CT attenuation values and ADC values measured on MR images may be helpful in differentiating AIP from PC.