1.In vivo study of the temperature changes of brain tissue surrounding microwave ablation zone in ;a canine model
Linggang, CHENG ; Wen, HE ; Lishu, WANG ; Huizhan, LI ; Wenyan, HUANG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2014;(3):59-62
Objective To investigate the alteration of peripheral tissue`s temperature of the coagulation zone of microwave ablation in brain tissue, and to provide experimental evidence for clinical application. Methods Twelve canines were treated by microwave ablation in brain tissue. Each was ablated for 180 s with microwave output power of 20 W, 30 W, and 40 W. During the operation the peripheral temperature at the distance of 0.5 cm, 1.0 cm, 1.5 cm and 2.0 cm from the ablation center was recorded respectively. The ultrasound was performed 1 hour after the operation, and then the animals were executed and the microscopic changes of the ablation lesion were observed. Results Eleven canines suffered well for the ablation, while 1 presented abnormal respiration during the operation and died 2 hours later. During the operation, the temperature of the area 0.5 cm from the center rose signiifcantly, with the maximum temperature was (96.40±1.46)℃at the power of 20 W, and 100℃at the power of 30 W and 40 W. The temperature of the area 1.0 cm from the center rose faster, with the maximum temperatures at different powers all above the 46℃. The temperature of the area 1.5 cm from the center rose slower, with the maximum temperature below 46℃at the power of 20 W and 30 W and above 46℃at the power of 40 W. The maximum temperatures of the area 2.0 cm from the center at different powers were all below 46℃. The difference of the maximum temperature at different distances (1.0 cm, 1.5 cm, and 2.0 cm from the center) was signiifcant (F=776.78, 2640.64 and 3025.53, all P<0.05). The length and width of the ablation lesion as well as the area of edema increased with the power. At the power of 20 W, 30 W, and 40 W, the length of the ablation lesion was (29.3±1.8) mm, (32.7±2.1) mm and (34.2±2.4) mm, the width was (22.5±1.5) mm, (23.7±1.7) mm and (27.1±2.0) mm, and the width of the edema zone was (2.3±0.4) mm, (2.6±0.4) mm and (2.7±0.5) mm. The differences of the length and width of the ablation lesion at different powers were signiifcant (F=11.46, 14.49, both P<0.01). The difference of the edema area at different powers was insigniifcant (F=1.94, P=0.169). Conclusions Microwave ablation is a safe therapeutic modality. However, the shorter distance from the ablation center and greater ablation power give rise to larger ablation lesion, higher maximum temperature, and faster temperature increase. Therefore, 2.0 cm from the ablation center is a safe area.
2.Study of carotid arteriosclerosis plaque by ultrasound real-time tissue elastography in patients with TOAST1 style cerebral infarction
Linggang, CHENG ; Wen, HE ; Hongxia, ZHANG ; Lishu, WANG ; Chen, LI
Chinese Journal of Medical Ultrasound (Electronic Edition) 2015;(7):536-540
Objective To evaluate the vulnerability of carotid arteriosclerosis plaque by ultrasound real-time tissue elastography in patients with SSS-TOAST1 style cerebral infarction, and discussing the value of the technique in assessment of the clinical course after cerebral infarction. Methods There were 113 patients of SSS-TOAST1 style cerebral infarction who had carotid arteriosclerosis plaque and 48 patients of contrast group who had carotid arteriosclerosis plaque selected by ultrasound in Department of Ultrasound, Beijing Tiantan Hospital, Capital University of Medical Sciences. The results between two groups were compared. The cerebral infarction group was divided into two sub-groups according to the clinical course of patients after cerebral infarction, and the difference between them was compared. Results The size had no significant difference between cerebral infarction group and contrast group as well as between aggravated group and non-aggravated group (t=15.61, 10.77, 4.52, P<0.05). The real-time tissue elastography of carotid arteriosclerosis plaques were red-green in most patients of cerebral infarction group. The real-time tissue elastography of carotid arteriosclerosis plaques were green-blue in most patients of in control group. The value of elasticity of plaque, vessel wall and stiffness of carotid arteriosclerosis plaque between cerebral infarction group and control group had significant differences (t=15.61, 10.77, 4.52, P<0.05). The value of real-time tissue elastography between aggravated group and non-aggravated group had significant difference (t=6.39, 2.30, 3.80, P<0.05). Conclusion Real-time tissue elastography could evaluate the stiffness of carotid arteriosclerosis plaque, which was related with the vulnerability of carotid arteriosclerosis plaque. The values of elasticity of plaque, vessel wall and stiffness of carotid arteriosclerosis plaque in patients with SSS-TOAST1 style cerebral infarction were lower, and the vulnerability of carotid arteriosclerosis plaque was higher. Real-time tissue elastography had some worth in evaluating the clinical course of patients after cerebral infarction.
3.Clinical study on contrast-enhanced ultrasound in traumatic brain injury
Huizhan LI ; Wen HE ; Linggang CHENG ; Lishu WANG ; Bin NING ; Ye CHENG
Chinese Journal of Ultrasonography 2013;(4):313-316
Objective To explore the value of contrast-enhanced ultrasound (CEUS) in classifying lesions,measuring the range of lesions,and the ability of manifesting the boundary and the severity of lesions after traumatic brain injury.Methods 83 patients with traumatic brain injury underwent the emergency surgery operations were enrolled in this study.Intraoperative ultrasound was applied in detecting the echo characteristics of lesions and classifying.Traumatic brain injuries which were classified indefinitely by conventional ultrasound were examined by CEUS to observe enhanced features of trauma lesions and the surrounding tissue,confirm the types of lesions,identify the border of lesions,measure the range of lesions,and compare with conventional ultrasound,preoperative CT and operative results.The severity of lesions was judged according to the parameter of time intensity curve (TIC).The results which would help the operators to adjust the method of treatment timely was informed.Results 148 lesions were detected by intraoperative ultrasound among 83 patients in this study.Thirty-two lesions which were classified indefinitely by conventional ultrasound were examined by CEUS.The results of classifying were confirmed by CT and operations,the diagnostic accuracy rate was 100%.The absolute peak intensity was changed with the injury severity,the more serious of the tissue,the lower absolute peak intensity was displayed.The boundary of lesions was manifested clearly after CEUS.Compare to the conventional ultrasonography,the range of lesions was larger.The difference between them was meaningful significally(P =0.01).Based on the results of CEUS,the way of operation was adjusted in 21 lesions.Conclusions Using the contrastenhanced ultrasound and intraoperative ultrasound,various traumatic brain injuries can be diagnosed accurately.By CEUS,the perfusion of lesions would be displayed,which would hint the severity of the brain tissue and help the operators adjust the methods of treatment timely,and provide the reliable evidence for the operation precisely.
4.Clininal research of transcranial color-coded ultrasonography and contrast-enhanced ultrasonography in intracerebral hemorrhage
Ye CHENG ; Wen HE ; Hongxia ZHANG ; Linggang CHENG ; Hao FENG ; Fenglan TIAN
Chinese Journal of Ultrasonography 2013;(3):213-217
Objective To explore the characteristic of transcranial color-coded sonography(TCCS)and contrast-enhanced transcranial color-coded sonography (CE-TCCS) in patients with intracerebral hemorrhage and thiers clinical value.Methods 66 patients were randomly selected,whose preliminary clinical diagnosis were intracerebral hemorrhage (ICH).The patients were followed up by TCCS in acute phase,subacute phase and chronic phase.The changes of the echo,boundary and the hematoma volume were recorded in different stages.In acute phase,patients' complications of intracerebral structure were observed.32 patients were selected randomly to underwent CE-TCCS examination in the subacute phase.The size,shape and the perfusion situation of hematoma were observed.The results of CE-TCCS were compared with the results of TCCS.Correlation analysis was made between the results of ultrasound and CT scan.Results (1) CT results:61 patients (61/66) were confirmed ICH through CT scan.(2) TCCS results:50 patients (50/61) with ICH could show the bleeding site.TCCS showed that 33 patients with ICH accompanied by intraventricular pressure,haematoma defeats ventricle and midline shift in acute phase.The echo became lower and the boundary became more clear with time.The long diameter,wide diameter,thickness diameter and volume of hematoma in different stages on TCCS had a good correlation with that on CT scan.(3)CE-TCCS results:30 cases of intracerebral hematoma could be clearly displayed the situation of hematoma through the ipsilateral temporal window.Compared with TCCS,CE TCCS had a better correlation with CT scan on the measurement of the hematoma length,width.The images of 2 cases observed through contralateral temporal window failded to be clearly shown.In 7 cases of ICH,visible low-enhanced edema area could be seen around the hematoma.The width of the edema area had a good correlation with the CTP result.Conclusions TCCS could clearly show the bleeding sites,hematoma volume and complications and the features of ICH in different stages of disease.TCCS could be used to monitor the condition of patients with ICH and recognized the disease progression initially.CE-TCCS had a much more clear display of intracerebral hematoma location,shape,boundary.At the same time,CE-TCCS could provide blood perfusion information of surrounding tissue in hematoma so that it could observe the change of peripheral edema more convenient.
5.A comparative study on internal jugular vein valve insufficiency by colour Doppler ultrasound and contrastenhanced ultrasound
Hongxia ZHANG ; Wen HE ; Lijuan DU ; Chen LI ; Linggang CHENG ; Xiaoya LI
Chinese Journal of Ultrasonography 2013;22(12):1031-1035
Objective To explore the ultrasonographic characteristics of internal jugular vein(IJV) valve insufficiency and reflux.Methods 40 healthy volunteers' bilateral IJVs were study subjects.The inner diameter,valve morphological feature,reflux distance and hemodynamic parameters in IJV were detected by color Doppler ultrasound (CDU),the contrast agents transvalvular regurgitation in IJV was monitored by contrast-enhanced ultrasound (CEUS) (with low mechanical index,MI 0.10),then analyse the results of two methods.Results Of 80 investigated IJVs,1 vein was excluded due to absence of its left valve,so 79 veins were evaluated in the study.The IJV's inner diameter on the right side was larger than on the left side,but there was no significant difference (P >0.05).The detection rate of IJV valve insufficiency was 31.6% (25/79),which was higher on the right than that on the left,but without significant difference (P > 0.05).The detection rate of IJV valve insufficiency was significantly higher in the group of greater than or equal to 50 years old than that in less than 50 years old(P <0.05).The reflux distance in IJV displayed by CDU was associated with IJV valve's function.Compaired with sufficient valves,the reflux duration time in insufficient valves during quiet respiration showed no significant difference (P >0.05).During Valsalvalike manoeuvres and quiet respiration,the reflux duration time in sufficient valves showed no significant difference (P > 0.05).The reflux duration time in insufficient valves during Valsalva-like manoeuvres showed significantly higher than that during quiet respiration (P <0.01).Compaired with sufficient valves,the peak flow velocity of reflux flow in insufficient valves was significantly prolonged during quiet respiration and Valsalva-like manoeuvres (P <0.05,P <0.01,respectively).Conclusions The incidence rate of IJV valve insufficiency and reflux is high in healthy individuals.During quiet respiration and/or Valsalva-like manoeuvres,detecting the reflux distance,reflux duration time and peak flow velocity of reflux flow by CDU are valuable in evaluating IJV valve insufficiency and the degree of IJV reflux.
6.Correlation of intraoperative ultrasonography and immunohistochemical markers expression in glioma
Haige YU ; Wen HE ; Linggang CHENG ; Zhanqiang JIN ; Mengze LIU ; Shiji WEI ; Haixin LI
Chinese Journal of Medical Imaging Technology 2018;34(6):831-835
Objective To investigate the correlation between intraoperative ultrasonographic features and expression of immunohistochemical markers in patients with glioma.Methods Totally 116 patients with glioma confirmed pathologically were collected.Ultrasonic features were observed,including the main site of the tumor,maximum diameter,border,cystic degeneration,calcification,the degree of peritumoral edema and CDFI blood flow classification,and the correlation between ultrasonographic features and immunohistochemical results such as Ki-67 and isocitrate dehydrogenase 1 (IDH1) was analyzed.Results Univariate analysis showed that the border,peritumoral edema and CDFI blood flow were significantly different between negative and positive Ki-67 expression patients (P< 0.01).The border,cystic degeneration and peritumoral edema were distinct between negative and positive IDH1 patients (P<0.01).Multivariate analysis showed that gliomas with clear border,high degree of peritumoral edema and rich CDFI blood flow tended to show positive Ki-67 expression,while those with vague border,low degree of peritumoral edema were frequently accompanied by positive IDH1 expression.Conclusion The border of gliomas,peritumoral edema and blood flow showed on ultrasonography may predict the expression of Ki-67 and IDH1.It is of great significance for preliminary evaluation on biological behaviors and prognosis of the tumors before surgical operation.
7.Seven thyroid imaging reporting and data systems for differentiating benign and malignant thyroid nodules under the context of Hashimoto thyroiditis
Xin SUN ; Wei ZHANG ; Linggang CHENG ; Yang GUANG ; Yukang ZHANG
Chinese Journal of Medical Imaging Technology 2024;40(2):212-216
Objective To compare the value of 7 different thyroid imaging reporting and data systems(TI-RADS)for differentiating benign and malignant thyroid nodules under the context of Hashimoto thyroiditis(HT).Methods A total of 338 thyroid nodules in 200 HT patients were enrolled,including 167 benign and 171 malignant ones.Kwak-TIRADS,American Thyroid Association(ATA)guideline,American Association of Clinical Endocrinologists(A ACE)/American College of Endocrinology(ACE)/Associazione Medici Endocrinologi(AME)guideline,K-TIRADS of Korean Society of Thyroid Radiology,EU-TIRADS of European Thyroid Association,American College of Radiology(ACR)-TIRADS and 2020 Chinese guidelines for malignant risk stratification of thyroid nodules by ultrasound proposed by the superficial organs and vessels group of the ultrasound medicine branch of the Chinese Medical Association(C-TIRADS)were used for grading of benign and malignant thyroid nodules.Taken pathological results as gold standards,the diagnostic efficacy of 7 kinds of TI-RADS were analyzed.Results The sensitivity of Kwak-TIRADS,ATA guideline,A ACE/ACE/AME guideline,K-TIRADS,EU-TIRADS,ACR-TIRADS and C-TIRADS for differentiating benign and malignant thyroid nodules under the context of HT was 97.08%,98.25%,99.42%,95.91%,99.42%,90.06%and 99.42%,respectively,the specificity was 88.02%,83.23%,82.04%,88.02%,82.04%,86.83%and 84.43%,respectively,and the area under the curve(AUC)was 0.946,0.913,0.907,0.934,0.909,0.916 and 0.960,respectively.The sensitivity of C-TIRADS,EU-TIRADS and A ACE/ACE/AME guideline were all higher than that of K-TIRADS and ACR-TIRADS(all P<0.05),and the specificity of Kawk-TIRADS and K-TIRADS were both higher than that of C-TIRADS,ATA guideline,EU-TIRADS and AACE/ACE/AME guideline(all P<0.05),while AUC of C-TIRADS and Kawk-TIRADS were both higher than that of the rest 5 kinds of TI-RADS(all P<0.05).According to Kwak-TIRADS,ATA guideline,AACE/ACE/AME guideline,K-TIRADS,EU-TIRADS,ACR-TIRADS and C-TIRADS,the malignant rate of different grades nodules identified with the same TI-RADS were significant different(all P<0.05),which all raised with the increase of TI-RADS grade.Conclusion C-TIRADS and Kawk-TIRADS had better value for differentiating benign and malignant thyroid nodules under the context of HT,among which C-TIRADS had higher sensitivity and Kawk-TIRADS had higher specificity.
8.Application value of S-Detect combined with contrast-enhanced ultrasound in the Breast Imaging Reporting and Data System 4 breast lesions
Jin JIN ; Wen HE ; Tengfei YU ; Yang GUANG ; Hongxia ZHANG ; Linggang CHENG ; Wei ZHANG
Chinese Journal of Ultrasonography 2023;32(5):392-398
Objective:To assess the value of S-Detect and contrast-enhanced ultrasound (CEUS) in the differential diagnosis of Breast Imaging Reporting and Data System(BI-RADS) 4 breast lesions.Methods:A total of 104 breast lesions in 100 patients diagnosed as BI-RADS category 4 by conventional ultrasound were prospectively enrolled, and all of them were received S-Detect and CEUS examination at the same time. Taking pathology as the gold standard, ROC curve was constructed to compare the diagnostic efficacy of conventional ultrasound, S-Detect, CEUS and their combination.Results:Among the 104 BI-RADS category 4 breast lesions, 63 were benign and 41 were malignant. The sensitivities of conventional ultrasound, S-Detect, CEUS and S-Detect combined with CEUS were 73.17%, 87.80%, 87.80%, 90.24%; the specificities were 57.14%, 60.32%, 68.25%, 77.78%; the positive predictive values were 52.63%, 59.02%, 64.29% and 72.55%; the negative predictive values were 76.60%, 88.37%, 89.59% and 92.45%; the accuracies were 63.46%, 71.15%, 75.96% and 82.69%; and the areas under the ROC curve (AUC) were 0.652, 0.741, 0.780 and 0.840. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of S-Detect and CEUS diagnosis were improved compared with conventional ultrasound. The AUC of combined diagnosis was higher than that of S-Detect, CEUS alone, and the differences were statistically significant(all P<0.05). The AUC of CEUS was higher than that of conventional ultrasound, and the difference was statistically significant ( P<0.05). There were no significant differences in AUC between any two of other groups (all P>0.05). Conclusions:The combined application of S-Detect and CEUS could achieve complementary advantages, which is of great significance for the differential diagnosis of benign and malignant in BI-RADS 4 breast lesions.